Jian Zheng

Jian Zheng

Auto-generated profile, based on publicly available information

Jian Zheng

Department of Medical Ultrasonics, The Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, People's Republic of China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2014 in European Radiology
Verified
Journal Article
Closed access
PDF file
JZJie Zeng
Jie Zeng
GLGuang-Jian Liu
Guang-Jian Liu
ZHZe-Ping Huang
Ze-Ping Huang
JZJian Zheng
Jian Zheng
TWTao Wu
Tao Wu
MLMing-De Lu
Ming-De Lu

1 March 2014 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
CWCong-Zhi Wang
Cong-Zhi Wang
JZJian Zheng
Jian Zheng
ZHZe-Ping Huang
Ze-Ping Huang
YXYang Xiao
Yang Xiao
DSDan Song
Dan Song
RZRong-Qin Zheng
Rong-Qin Zheng

1 November 2014 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
ZHZeping Huang
Zeping Huang
JZJian Zheng
Jian Zheng
JZJie Zeng
Jie Zeng
XWXiaoli Wang
Xiaoli Wang
TWTao Wu
Tao Wu
RZRongqin Zheng
Rongqin Zheng

28 July 2014 in World Journal of Gastroenterology
Verified
Journal Article
Open access
ZHZe-Ping Huang
Ze-Ping Huang
XZXin-Ling Zhang
Xin-Ling Zhang
JZJie Zeng
Jie Zeng
JZJian Zheng
Jian Zheng
PWPing Wang
Ping Wang
RZRong-Qin Zheng
Rong-Qin Zheng
AIM: To investigate enough valid measurements (VMs) to assess liver fibrosis in chronic hepatitis B patients (CHB). METHODS: One hundred and twelve CHB patients (25 women, 87 men) with a mean age of 38.43 years received liver stiffness evaluations using real-time shear wave elastography for 10 VMs. All patients underwent liver biopsy. Based on the biopsy pathology, the liver stiffness data obtained from different VMs (1, 2, 3, 5 and 10 times) were compared for the evaluation of liver fibrosis. The correlation between the elastic modulus means of the liver obtained from different VMs of detection at each pathological stage was analysed. The receiver operating characteristic (ROC) curve was employed to determine the diagnostic performance of different VMs of detection, and the areas under the ROC curve of different groups were compared. RESULTS: The liver stiffness values obtained from 1 VM, 2 VMs, 3 VMs, 5 VMs and all 10 VMs for stage F0 were 6.95 ± 2.01 kPa, 6.87 ± 1.83 kPa, 6.90 ± 1.88 kPa, 6.95 ± 1.93 kPa and 7.15 ± 1.89 kPa, respectively (F = 0.043, P = 0.996). For stage F1, these values were 7.12 ± 1.72 kPa, 7.24 ± 1.72 kPa, 7.21 ± 1.74 kPa, 7.10 ± 1.78 kPa and 7.04 ± 1.70 kPa, respectively (F = 0.075, P = 0.990). For stage F2, they were 9.37 ± 3.87 kPa, 9.18 ± 3.68 kPa, 9.19 ± 3.81 kPa, 9.18 ± 3.81 kPa and 9.19 ± 3.53 kPa, respectively (F = 0.012, P = 1.000). For stage F3, these were 11.91 ± 3.88 kPa, 11.78 ± 4.04 kPa, 11.83 ± 4.07 kPa, 11.94 ± 4.17 kPa and 12.00 ± 4.02 kPa, respectively (F = 0.010, P = 1.000). For stage F4, the readings were 19.30 ± 7.63 kPa, 19.40 ± 7.36 kPa, 19.54 ± 7.43 kPa, 19.73 ± 7.21 kPa and 20.25 ± 7.22 kPa, respectively (F = 0.054, P = 0.995). There were no significant differences between these groups. Intraclass correlation coefficients among different pathological stages (F0-F4) with different detection VMs were 0.995, 0.993, 0.996, 0.994 and 0.996, respectively. The mean elasticity values from 1 VM, 2 VMs, 3 VMs, 5 VMs and 10 VMs can accurately distinguish fibrosis stages (F0 vs F1234, F01 vs F234, F012 vs F34 and F0123 vs F4) with no significant differences in the five groups (P > 0.05 for all). CONCLUSION: One VM may be sufficient to assess liver fibrosis by using SWE without any significant loss of accuracy in patients with CHB. However, future studies of larger patient samples are necessary for the validation of this method.

1 November 2011 in Chinese Physics B
Verified
Journal Article
Closed access
YZYan-Li Zhang
Yan-Li Zhang
HZHai-Rong Zheng
Hai-Rong Zheng
MTMeng-Xing Tang
Meng-Xing Tang
DZDong Zhang
Dong Zhang

1 July 2013
Verified
Conference Paper
Closed access
CWCong-Zhi Wang
Cong-Zhi Wang
YXYang Xiao
Yang Xiao
DSDan Song
Dan Song
YMYan Ming
Yan Ming
HZHai-Rong Zheng
Hai-Rong Zheng
RZRong-Qin Zheng
Rong-Qin Zheng
The purpose of this study was to evaluate the influence of measurement depth on the results of real-time shear wave elastography (SWE) measurements and to find a reliable measurement depth range for liver stiffness assessment using SWE. SWE measurements were performed on an Elasticity Quality Assurance phantom and healthy volunteers' livers. The different depths from probe surface and from liver capsule were studied in 30 and 88 healthy volunteers, separately. The success rate of measurements (SRoM), success rate of subjects (SRoS), and coefficients of variation (CV) of repeated measurements were calculated and compared. In phantom study, the CV at 2-6cm depth (from 0.6% to 0.9%) was larger than those at the other depths (from 2.8% to 9.8%). For the first group of healthy volunteers, the SRoMs at 3-7cm depths were significantly higher than the others, and the measured results were found to be more reliable at 2-5cm (P<;0.001). In the second group of subjects, the SRoSs at 1-4cm depths below liver capsule were all 100% but at 0-1cm depth was zero. According to our results, the most reliable depth range of liver stiffness assessment using SWE should be 3-5cm from the probe surface and simultaneously 1-2cm below the liver capsule.