Sripriya Rengaraju

Sripriya Rengaraju

Auto-generated profile, based on publicly available information

Sripriya Rengaraju

University of Cambridge

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Cement and Concrete Research
Verified
Journal Article
Closed access
RPRadhakrishna G. Pillai
Radhakrishna G. Pillai
RGRavindra Gettu
Ravindra Gettu
MSManu Santhanam
Manu Santhanam
SRSripriya Rengaraju
Sripriya Rengaraju
YDYuvaraj Dhandapani
Yuvaraj Dhandapani
ABAnusha S. Basavaraj
Anusha S. Basavaraj

1 June 2019 in Electrochimica Acta
Verified
Journal Article
Closed access
SRSripriya Rengaraju
Sripriya Rengaraju
LNLakshman Neelakantan
Lakshman Neelakantan
RPRadhakrishna G. Pillai
Radhakrishna G. Pillai

30 November 2022 in Cement and Concrete Composites
Verified
Journal Article
Closed access
RARami Alghamri
Rami Alghamri
SRSripriya Rengaraju
Sripriya Rengaraju
AAAbir Al-Tabbaa
Abir Al-Tabbaa

10 June 2025 in Cement and Concrete Composites
Verified
Journal Article
Open access
RMRenjie Mi
Renjie Mi
SRSripriya Rengaraju
Sripriya Rengaraju
AAAbir Ai-Tabbaa
Abir Ai-Tabbaa

1 February 2020 in Magazine of Concrete Research
Verified
Journal Article
Closed access
SRSripriya Rengaraju
Sripriya Rengaraju
AGAnand Godara
Anand Godara
PAPrasanth Alapati
Prasanth Alapati
RPRadhakrishna G. Pillai
Radhakrishna G. Pillai
This paper investigates the mechanisms of corrosion of seven-wire strands and the reasons for failures in detecting corrosion at early stages. As per ASTM G109 and ACI 222 R-01, a 1-year study on chloride-induced corrosion of seven-wire prestressing strands embedded in various concretes was conducted. The type of corrosion current circuits in the prismatic specimens with one top and two bottom strands was investigated. Unlike solid rebars, the concrete resistivity had a limited role on the type of corrosion circuits in strand systems, with a high probability of corrosion occurring between different wires in the top strand itself. This may be due to the flower-like geometry and the complex corrosion mechanisms within the top strand. It is recommended to perform other electrochemical measurements on the top strand – prior to making conclusions. Also, until about 6% corrosion loss is reached, the rust will fill the interstitial space between the seven wires and will not exert expansive stresses on the surrounding concrete. Hence, no staining/cracking will be visible on the concrete surface – a serious structural safety issue – necessitating frequent chloride/corrosion condition assessment of prestressed-concrete structures.

9 June 2025 in Journal of Building Engineering
Verified
Journal Article
Closed access
SRSripriya Rengaraju
Sripriya Rengaraju
NANoemi Arena
Noemi Arena
FKFragkoulis Kanavaris
Fragkoulis Kanavaris
AJAgnieszka Jędrzejewska
Agnieszka Jędrzejewska
AAAbir Al-Tabbaa
Abir Al-Tabbaa