Richard Barnes

Richard Barnes

Auto-generated profile, based on publicly available information

Richard Barnes

Monash Childrens Hosp, Dept Anaesthet, 246 Clayton Rd, Melbourne, Australia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2020 in The Journal of Vascular Access
Verified
Journal Article
Closed access
KQKirby Qin
Kirby Qin
NENicholas Ensor
Nicholas Ensor
RBRichard Barnes
Richard Barnes
AEAnna Englin
Anna Englin
RNRamesh M Nataraja
Ramesh M Nataraja
MPMaurizio Pacilli
Maurizio Pacilli
Background: Long peripheral catheters are peripheral intravenous catheters of 6–15 cm in length. They are commonly inserted into the forearm, antecubital fossa or upper arm using a direct Seldinger technique. They have proven to be valuable for peripheral intravenous catheters, particularly in patients with difficult intravenous access. Methods: We conducted a systematic review of studies reporting the use of long peripheral catheters. The following keywords were used: ‘long’, ‘Seldinger’, ‘guidewire’, ‘peripheral’, ‘venous’, ‘intravenous’, ‘IV’, ‘vascular’, ‘cannula’ and ‘catheter’. Results: Three hundred forty-one publications were identified; 16 were included in the systematic review. There were 11 adult studies and 5 paediatric studies documenting 1288 long peripheral catheters in 1271 patients. Majority of studies (12/16) were conducted in acute care settings, (emergency department, n = 6; intensive care unit, n = 3; high dependency unit, n = 1; surgical unit, n = 2). The most frequently studied long peripheral catheter was 8 cm in length and 20 G in size. Nine studies recruited patients with difficult intravenous access; 11 studies used ultrasound guidance. Insertion success rate and mean procedural time ranged between 86% and 100% and 8 and 16.8 minutes, respectively. Average catheter duration ranged between 4 and 14.7 days (mean) and 1.1 and 9 days (median). Catheter failure occurred in 4.3–52.5% of long peripheral catheters, with leakage, infiltration and dislodgement being the most frequent causes of failure. In 3 randomised controlled trials, long peripheral catheters outperformed peripheral intravenous catheters in terms of duration and failure rate. Conclusion: Long peripheral catheters are safe and reliable in both adults and children. In addition, long peripheral catheters may provide improved quality of care over peripheral intravenous catheters for multi-day intravenous therapy.

11 May 2023 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
ALAshleigh Laird
Ashleigh Laird
LBLynsey Bramley
Lynsey Bramley
RBRichard Barnes
Richard Barnes
AEAnna Englin
Anna Englin
JWJacinta Winderlich
Jacinta Winderlich
MPMaurizio Pacilli
Maurizio Pacilli

5 May 2020 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
KFKathryn Marie Fitzsimons
Kathryn Marie Fitzsimons
JSJoseph Speekman
Joseph Speekman
TSTemora Senior
Temora Senior
KCKerrie Curtis
Kerrie Curtis
ACAlex Cochrane-Davis
Alex Cochrane-Davis
RBRichard Barnes
Richard Barnes
Paediatric central venous access devices are associated with significant complications. Failure rates have been estimated to be as high as 25%, with securement failure a significant contributing factor. In this study, we evaluate the use of a subcutaneous securement device, securAcathTM, in minimising rates of central venous access device dislodgement and unintended early removal within a paediatric population. Data were collected on 52 consecutive paediatric patients, aged less than 18 years old, who required peripherally inserted central catheters and non-cuffed tunnelled centrally inserted central catheters. We found that the rate of securement failure with securAcathTM was 2.01 per 1000 catheter days. This compared to 2.58 in our previous practice without securAcathTM. With the use of securAcathTM, no securement failures were observed in our patients with non-cuffed tunnelled centrally inserted central catheters. There were three instances of securement failure in patients with peripherally inserted central catheters. We conclude that the use of a securAcathTM fixation device in central venous access devices is an effective method of securement, especially in use with non-cuffed tunneled centrally inserted central catheters. However, when significant tension is applied to the central venous access devices migration is still possible.

7 February 2023 in The Journal of Vascular Access
Verified
Journal Article
Closed access
KQKirby Qin
Kirby Qin
NENicholas Ensor
Nicholas Ensor
MDMatthew D’aMore
Matthew D’aMore
RBRichard Barnes
Richard Barnes
RNRamesh M Nataraja
Ramesh M Nataraja
MPMaurizio Pacilli
Maurizio Pacilli

26 March 2021 in The Journal of Vascular Access
Verified
Journal Article
Closed access
PDF file
BZBella Zhong
Bella Zhong
RBRichard Barnes
Richard Barnes
AMAtul Malhotra
Atul Malhotra
PPPramod Pharande
Pramod Pharande
Achieving and maintaining venous access can be challenging in some premature and low birth weight infants. In this population, the supraclavicular ultrasound-guided in-plane approach to the brachiocephalic vein for central venous access has demonstrated great success with a low rate of complications. This case describes the first report of acquired chylothorax in association with this technique, in a previously extremely preterm and low birth weight infant.