Marinus Huber

Marinus Huber

Auto-generated profile, based on publicly available information

Marinus Huber

Ludwig-Maximilians-Universität München

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 March 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
MHMarinus Huber
Marinus Huber
KKKosmas V. Kepesidis
Kosmas V. Kepesidis
LVLiudmila Voronina
Liudmila Voronina
MBMaša Božić
Maša Božić
MTMichael Trubetskov
Michael Trubetskov
MŽMihaela Žigman
Mihaela Žigman
Health state transitions are reflected in characteristic changes in the molecular composition of biofluids. Detecting these changes in parallel, across a broad spectrum of molecular species, could contribute to the detection of abnormal physiologies. Fingerprinting of biofluids by infrared vibrational spectroscopy offers that capacity. Whether its potential for health monitoring can indeed be exploited critically depends on how stable infrared molecular fingerprints (IMFs) of individuals prove to be over time. Here we report a proof-of-concept study that addresses this question. Using Fourier-transform infrared spectroscopy, we have fingerprinted blood serum and plasma samples from 31 healthy, non-symptomatic individuals, who were sampled up to 13 times over a period of 7 weeks and again after 6 months. The measurements were performed directly on liquid serum and plasma samples, yielding a time- and cost-effective workflow and a high degree of reproducibility. The resulting IMFs were found to be highly stable over clinically relevant time scales. Single measurements yielded a multiplicity of person-specific spectral markers, allowing individual molecular phenotypes to be detected and followed over time. This previously unknown temporal stability of individual biochemical fingerprints forms the basis for future applications of blood-based infrared spectral fingerprinting as a multiomics-based mode of health monitoring.

26 October 2021 in eLife
Verified
Journal Article
Open access
MHMarinus Huber
Marinus Huber
KKKosmas V Kepesidis
Kosmas V Kepesidis
LVLiudmila Voronina
Liudmila Voronina
FFFrank Fleischmann
Frank Fleischmann
EFErnst Fill
Ernst Fill
MZMihaela Zigman
Mihaela Zigman
Recent omics analyses of human biofluids provide opportunities to probe selected species of biomolecules for disease diagnostics. Fourier-transform infrared (FTIR) spectroscopy investigates the full repertoire of molecular species within a sample at once. Here, we present a multi-institutional study in which we analysed infrared fingerprints of plasma and serum samples from 1639 individuals with different solid tumours and carefully matched symptomatic and non-symptomatic reference individuals. Focusing on breast, bladder, prostate, and lung cancer, we find that infrared molecular fingerprinting is capable of detecting cancer: training a support vector machine algorithm allowed us to obtain binary classification performance in the range of 0.78–0.89 (area under the receiver operating characteristic curve [AUC]), with a clear correlation between AUC and tumour load. Intriguingly, we find that the spectral signatures differ between different cancer types. This study lays the foundation for high-throughput onco-IR-phenotyping of four common cancers, providing a cost-effective, complementary analytical tool for disease recognition.

7 September 2017 in Optics Express
Verified
Journal Article
Closed access
PDF file
MHMarinus Huber
Marinus Huber
WSWolfgang Schweinberger
Wolfgang Schweinberger
FSFabian Stutzki
Fabian Stutzki
JLJens Limpert
Jens Limpert
IPIoachim Pupeza
Ioachim Pupeza
OPOleg Pronin
Oleg Pronin
Excess relative intensity noise (RIN) constitutes one of the major limitations of most spectroscopic methods involving lasers. Here, we present an active RIN suppression scheme for a coherent mid-infrared (MIR) light source (8.4-11 µm), based on intra-pulse difference frequency generation (DFG). Three different stabilization concepts that rely on modulating the intensity of the driving near-infrared (NIR) pulse train with an acousto-optic modulator are investigated and compared. By using the wings of the NIR spectrum to generate the error signal, a RIN suppression of the MIR pulse train of up to a factor of 20 was achieved in the band between 1 Hz and 100 kHz, resulting in a total integrated RIN of 0.07%.

30 April 2020 in Analytical Chemistry
Verified
Journal Article
Open access
MHMarinus Huber
Marinus Huber
MTMichael Trubetskov
Michael Trubetskov
SHSyed Ali Hussain
Syed Ali Hussain
WSWolfgang Schweinberger
Wolfgang Schweinberger
CHChristina Hofer
Christina Hofer
IPIoachim Pupeza
Ioachim Pupeza
The strong absorption of liquid water in the infrared (IR) molecular fingerprint region constitutes a challenge for applications of vibrational spectroscopy in chemistry, biology and medicine. While high-power IR laser sources enable the penetration of ever thicker aqueous samples, thereby mitigating the detrimental effects of strong attenuation on detection sensitivity, a basic advantage of heterodyne-measurement-based methods has – to the best of our knowledge – not been harnessed in broadband IR measurements to date. Here, employing field-resolved spectroscopy (FRS), we demonstrate in theory and experiment fundamental advantages of techniques whose signal-to-noise ratio (SNR) scales linearly with the electric field over those whose SNR scales linearly with radiation intensity, including conventional Fourier-transform infrared (FTIR) and direct absorption spectroscopy. Field-scaling brings about two major improvements. Firstly, it squares the measurement dynamic range. Secondly, we show that the optimum interaction length with samples for SNR-maximized measurements is twice the value usually considered to be optimum for FTIR devices. In order to take full advantage of these properties, the measurement must not be significantly affected by technical noise, such as intensity fluctuations which are common for high-power sources. Recently, it has been shown that sub-cycle, non-linear gating of the molecular fingerprint signal renders FRS robust against intensity noise. Here, we quantitatively demonstrate this advantage of FRS for thick aqueous samples. We report sub-µg/ml detection sensitivities for transmission path lengths up to 80 µm and a limit of detection in the lower µg/ml range for transmission paths as long as 200 µm.

12 April 2023 in Analytical Chemistry
Verified
Journal Article
Open access
TETarek Eissa
Tarek Eissa
KKKosmas V. Kepesidis
Kosmas V. Kepesidis
MZMihaela Zigman
Mihaela Zigman
MHMarinus Huber
Marinus Huber

7 November 2024 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
TETarek Eissa
Tarek Eissa
LVLiudmila Voronina
Liudmila Voronina
MHMarinus Huber
Marinus Huber
FFFrank Fleischmann
Frank Fleischmann
MŽMihaela Žigman
Mihaela Žigman
Vibrational spectroscopy is a widely used technique for chemical characterizations across various analytical sciences. Its applications are increasingly extending to the analysis of complex samples such as biofluids, providing high‐throughput molecular profiling. While powerful, the technique suffers from an inherent limitation: The overlap of absorption information across different spectral domains hinders the capacity to identify individual molecular substances contributing to measured signals. Despite the awareness of this challenge, the difficulty of analyzing multi‐molecular spectra is often underestimated, leading to unsubstantiated molecular interpretations. Here, we examine the prevalent overreliance on spectral band assignment and illuminate the pitfalls of correlating spectral signals to discrete molecular entities or physiological states without rigorous validation. Focusing on blood‐based infrared spectroscopy, we provide examples illustrating how peak overlap among different substances, relative substance concentrations, and preprocessing steps can lead to erroneous interpretations. We advocate for a viewpoint shift towards a more careful understanding of complex spectra, which shall lead to either accepting their fingerprinting nature and leveraging machine learning analysis – or involving additional measurement modalities for robust molecular interpretations. Aiming to help translate and improve analytical practices within the field, we highlight the limitations of molecular interpretations and feature their viable applications.