Guang Yang

Guang Yang

Auto-generated profile, based on publicly available information

Guang Yang

Department of Biomedical Engineering, Key Laboratory of Biomedical Information Engineering, Ministry of Education, School of Life Science and Technology, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GYGuang Yang
Guang Yang
SZSiyuan Zhang
Siyuan Zhang
XLXiejing Li
Xiejing Li
TSTing Shen
Ting Shen
XJXin Jia
Xin Jia
PRPengyu Ren
Pengyu Ren
Many quantitative ultrasound imaging techniques based on tissue properties have been established to ensure the safety and efficacy of thermal ablation treatment. However, which quantitative ultrasound imaging technique has superior monitoring properties has not yet been revealed. In this study, we investigated and compared the performance of envelope data distribution-dependent ultrasonic Nakagami, envelope data distribution-independent horizontally normalized Shannon entropy (hNSE), and differential attenuation coefficient intercept (DACI) based on frequency domain imaging technique during liver thermal ablation treatments. Quantitative ultrasound parameter images were constructed simultaneously from radiofrequency (RF) data collected during the process of microwave ablation (MWA) treatments in ex vivo and in vivo porcine livers. Contrast-to-noise ratios (CNR) were calculated to evaluate the contrast resolution of different imaging techniques. The mean CNR value of hNSE images was 6.06 ± 2.34 dB, being significantly higher than that of Nakagami images ( p <0.05, statistical) and DACI images ( p <0.05, statistical). Furthermore, the receiver operating characteristic (ROC) was used to evaluate the thermal lesion detection ability. The area under the curve (AUC) of B-mode, Nakagami, hNSE and DACI was 0.823, 0.839, 0.86 and 0.825, respectively. Additionally, our data analysis exhibited that hNSE has the excellent property of ablation area detections in the present study, whose correlation coefficient is 0.91. In conclusion, our study suggests that hNSE imaging, which does not require the specific data distribution has the best performance in thermal ablation detections and is a promising imaging method for further clinical research and application.

26 February 2024 in Ultrasonics
Verified
Journal Article
Closed access
GYGuang Yang
Guang Yang
JLJing Liu
Jing Liu
BYBeiru Yang
Beiru Yang
JGJunfeng Guo
Junfeng Guo
CWChenxiaoyue Wu
Chenxiaoyue Wu
SZSiyuan Zhang
Siyuan Zhang

14 January 2023 in Ultrasonics
Verified
Journal Article
Closed access
XJXin Jia
Xin Jia
XLXiejing Li
Xiejing Li
TSTing Shen
Ting Shen
LZLing Zhou
Ling Zhou
GYGuang Yang
Guang Yang
SZSiyuan Zhang
Siyuan Zhang

6 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JLJing Liu
Jing Liu
SZSiyuan Zhang
Siyuan Zhang
XLXiejing Li
Xiejing Li
GYGuang Yang
Guang Yang
BYBeiru Yang
Beiru Yang
HWHua Wang
Hua Wang
Accurate and real-time monitoring of thermal ablation areas is an important guarantee for the safety and effectiveness of ablation treatment. Ultrasonic B-mode imaging can realize real-time monitoring, however it can not accurately correspond to the thermal ablation area. Contrast-enhanced ultrasound (CEUS) is clinically used for evaluating thermal ablation treatment with high accuracy, but hard to achieve real-time monitoring and guidance during ablation treatment. In this study, we explored the performance of horizontally normalized Shannon entropy (hNSE) in detecting and monitoring radiofrequency ablation on in vivo rabbit livers with CEUS images as in-situ references. The mean contrast-to-noise ratios (CNRs) of hNSE images was 3.8, being significantly higher than 1.2 of B-mode images (p<0.001). Larger distinction in probability distribution between values of ablated tissue and normal tissue was found in hNSE images than B-mode images. The area under receiver operating characteristic curve of hNSE and B-mode were 0.7760 and 0.6463 (p<0.0001). Additionally, better performance in area and axis length delineation of ablated tissue was found in hNSE, comparable to CEUS references with high correlation coefficients of 0.823, 0.814, and 0.792, respectively. In conclusion, these findings suggest that hNSE imaging could be a promising technique for real-time monitoring and guidance applied to ultrasound-guided thermal ablation treatment in clinical use.