20 April 2023 in IEEE Transactions on Instrumentation and Measurement
Many quantitative ultrasound imaging techniques based on tissue properties have been established to ensure the safety and efficacy of thermal ablation treatment. However, which quantitative ultrasound imaging technique has superior monitoring properties has not yet been revealed. In this study, we investigated and compared the performance of envelope data distribution-dependent ultrasonic Nakagami, envelope data distribution-independent horizontally normalized Shannon entropy (hNSE), and differential attenuation coefficient intercept (DACI) based on frequency domain imaging technique during liver thermal ablation treatments. Quantitative ultrasound parameter images were constructed simultaneously from radiofrequency (RF) data collected during the process of microwave ablation (MWA) treatments in ex vivo and in vivo porcine livers. Contrast-to-noise ratios (CNR) were calculated to evaluate the contrast resolution of different imaging techniques. The mean CNR value of hNSE images was 6.06 ± 2.34 dB, being significantly higher than that of Nakagami images ( p <0.05, statistical) and DACI images ( p <0.05, statistical). Furthermore, the receiver operating characteristic (ROC) was used to evaluate the thermal lesion detection ability. The area under the curve (AUC) of B-mode, Nakagami, hNSE and DACI was 0.823, 0.839, 0.86 and 0.825, respectively. Additionally, our data analysis exhibited that hNSE has the excellent property of ablation area detections in the present study, whose correlation coefficient is 0.91. In conclusion, our study suggests that hNSE imaging, which does not require the specific data distribution has the best performance in thermal ablation detections and is a promising imaging method for further clinical research and application.
26 February 2024 in Ultrasonics
14 January 2023 in Ultrasonics
6 March 2025 in IEEE Transactions on Instrumentation and Measurement
Accurate and real-time monitoring of thermal ablation areas is an important guarantee for the safety and effectiveness of ablation treatment. Ultrasonic B-mode imaging can realize real-time monitoring, however it can not accurately correspond to the thermal ablation area. Contrast-enhanced ultrasound (CEUS) is clinically used for evaluating thermal ablation treatment with high accuracy, but hard to achieve real-time monitoring and guidance during ablation treatment. In this study, we explored the performance of horizontally normalized Shannon entropy (hNSE) in detecting and monitoring radiofrequency ablation on in vivo rabbit livers with CEUS images as in-situ references. The mean contrast-to-noise ratios (CNRs) of hNSE images was 3.8, being significantly higher than 1.2 of B-mode images (p<0.001). Larger distinction in probability distribution between values of ablated tissue and normal tissue was found in hNSE images than B-mode images. The area under receiver operating characteristic curve of hNSE and B-mode were 0.7760 and 0.6463 (p<0.0001). Additionally, better performance in area and axis length delineation of ablated tissue was found in hNSE, comparable to CEUS references with high correlation coefficients of 0.823, 0.814, and 0.792, respectively. In conclusion, these findings suggest that hNSE imaging could be a promising technique for real-time monitoring and guidance applied to ultrasound-guided thermal ablation treatment in clinical use.