Chengyan Bai

Chengyan Bai

Auto-generated profile, based on publicly available information

Chengyan Bai

College of Energy and Power Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2026 in Bioactive Materials
Verified
Journal Article
Open access
YLYuechuan Li
Yuechuan Li
CDChengchen Deng
Chengchen Deng
DXDuanqiang Xiao
Duanqiang Xiao
CBChengyan Bai
Chengyan Bai
LCLebing Chang
Lebing Chang
GWGuixue Wang
Guixue Wang
Current biodegradable biliary stents remain inadequate for clinical demands. Zinc (Zn) alloys, exhibiting excellent mechanical properties, moderate degradation rates, and favorable biocompatibility, are potential materials for biodegradable biliary stents. In this study, trace boron (B) was added to Zn-0.8Cu alloy to enhance its mechanical properties and biocompatibility, and to investigate its suitability as biliary stent. The incorporation of 0.03 wt% boron significantly refined the grain size and introduced the bimodal organization, consequently enhancing the mechanical properties of Zn-0.8Cu alloy (As cast: yield strength, ultimate tensile strength, and elongation increased by 52.0 %, 42.5 %, and 153.8 %, respectively). Moreover, boron addition reduced the corrosion resistance of Zn-0.8Cu alloy and the surface became hydrophilic (water contact angle 70.75° ± 1.74°). In vitro evaluations revealed that the Zn-0.8Cu-0.03B alloy exhibited excellent biocompatibility and strongly inhibited the growth of Staphylococcus aureus and Escherichia coli. Finally, the Zn-0.8Cu-0.03B alloy stents maintained structural integrity in the rabbit common bile duct for 3 weeks, followed by accelerated degradation, and were completely degraded within 8 weeks. Zn-0.8Cu-0.03B alloy stents showed excellent biocompatibility in vivo, the degradation products were safely eliminated without causing biliary stricture or obstruction, and tissue hyperplasia induced by stent was effectively alleviated. In conclusion, this study expands the applications potential of Zn alloy in biomedicine and provides reference for developing new generation biodegradable biliary stents.

26 March 2025 in Biomedical Materials
Verified
Journal Article
Closed access
CBChengyan Bai
Chengyan Bai
XFXiangyi Feng
Xiangyi Feng
LLLiang Lan
Liang Lan
CZChao Zhou
Chao Zhou
HZHaijun Zhang
Haijun Zhang
Intervention without implantation has become a requirement for developing percutaneous coronary intervention for coronary heart disease. In this paper, the recent advances of three representative types of bioresorbable metal coronary drug-eluting stents (DESs) are reviewed, and the material composition, structural design, mechanical properties and degradability of iron-based, magnesium-based and zinc-based bioresorbable metal coronary DES are analyzed. The methods of regulating the radial strength and degradation rate of the coronary stents are summarized, and the in vivo/in vitro performance evaluation methods and ideal testing systems of the bioresorbable metal coronary DES are analyzed. Advances made in bioresorbable metal coronary DES, the existing shortcomings and optimization methods are proposed, and the future development direction is prospected.

1 November 2026 in Physics of Fluids
Verified
Journal Article
Closed access
CBChengyan Bai
Chengyan Bai
JLJian Lu
Jian Lu
KLKun Liu
Kun Liu
Liguo ZhaoLiguo Zhao
Liguo Zhao
Repeated high-G exposure is a health risk factor for high-performance fighter pilots, increasing the likelihood of adverse cardiovascular events. Current aviation cardiovascular research primarily focuses on overall cardiac compensation, yet coronary hemodynamics remain incompletely understood. This study aims to investigate the hemodynamic responses of left anterior descending (LAD) and left circumflex (LCx) arteries with varying bifurcation angles under high-G acceleration. Computational fluid dynamics simulations are carried out for LAD–LCx branch models under high-G conditions with varying magnitudes and directions. High-G effects have been incorporated through an acceleration body-force term and corresponding hydrostatic pressure corrections, with inlet velocity and outlet pressure adjusted for various acceleration levels. The results demonstrate a nonlinear correlation between bifurcation angles and atherosclerosis risk. Under Earth's gravity, the 85° bifurcation exhibits the highest risk in the LAD branch, associated with relatively weaker and less coherent helical flow, pronounced high-velocity core deflection, and increased low time-averaged wall-shear stress (TAWSS) exposure. Under +4 Gz condition, the risk associated with obtuse bifurcations increases markedly, accompanied by weakened helical flow and expanded low-TAWSS regions. A 30° reclined posture partially restores helical flow and reduces low-TAWSS exposure to approximately the level observed under +1 Gz. The Gx acceleration strengthens helical flow and increases high-TAWSS exposure near the bifurcation carina. This study reveals that high +Gz amplifies the adverse hemodynamic effects through changes in helical-flow intensity and wall-shear patterns, while seat recline under +Gz reduces the risk of atherosclerosis. Acceleration direction also plays a distinct role, with Gx acceleration increasing the risk of endothelial injury.