Jan Hinrichsen

Jan Hinrichsen

Auto-generated profile, based on publicly available information

Jan Hinrichsen

Institute of Continuum Mechanics and Biomechanics, Department of Mechanical Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 August 2023 in Journal of the Mechanics and Physics of Solids
Verified
Journal Article
Open access
MFMoritz Flaschel
Moritz Flaschel
HYHuitian Yu
Huitian Yu
NRNina Reiter
Nina Reiter
JHJan Hinrichsen
Jan Hinrichsen
SBSilvia Budday
Silvia Budday
LLLaura De Lorenzis
Laura De Lorenzis

28 December 2024 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
JFJessica Faber
Jessica Faber
JHJan Hinrichsen
Jan Hinrichsen
ASAnahita Ahmadi Soufivand
Anahita Ahmadi Soufivand
HLHsuan-Heng Lu
Hsuan-Heng Lu
TRTanja Rosenberger
Tanja Rosenberger
SBSilvia Budday
Silvia Budday
Extrusion-based 3D bioprinting is one of the most promising and widely used technologies in bioprinting. However, the development of bioprintable, biocompatible bioinks with tailored mechanical and biological properties remains a major challenge in this field. Alginate dialdehyde-gelatin (ADA-GEL) hydrogels face these difficulties and enable to tune the mechanical properties depending on the degree of oxidation (% DO) of ADA. Here, we present a holistic approach for characterizing the influence of the % DO on the mechanical properties of ADA-GEL hydrogels under multiple loading modes, compression, tension, and torsional shear in the large-strain regime. We evaluate complex mechanical characteristics including nonlinearity, hysteresis, conditioning, and stress relaxation. We calibrate hyperelastic material models to determine the corresponding material parameters inversely. Our results confirm that decreasing the % DO of ionically crosslinked ADA-GEL hydrogels leads to an increase in stiffness, more distinct nonlinearity, more pronounced hysteresis, and minor preconditioning effects, while the relaxation behavior is slightly affected. The fabrication technique - molding or printing - does only slightly affect the complex mechanical properties and stress relaxation behavior. Ionically and enzymatically dual-crosslinked ADA-GEL hydrogels showed higher stresses during cyclic loading and less viscous effects during stress relaxation in all three loading modes. We conclude that the % DO and the crosslinking procedure are crucial parameters to tune the mechanical behavior of ADA-GEL hydrogels. Careful choice of these parameters might facilitate the fabrication of biomaterials that closely mimic the properties of native tissues for advanced tissue engineering applications.

5 December 2025 in Advanced Healthcare Materials
Verified
Journal Article
Open access
DBDavid Böhringer
David Böhringer
JHJan Hinrichsen
Jan Hinrichsen
RGRadik Gataulin
Radik Gataulin
SWSandra Wiedenmann
Sandra Wiedenmann
MSMarina Spörrer
Marina Spörrer
SBSilvia Budday
Silvia Budday
Collagen type I hydrogels, which self‐assemble into 3D fiber networks, are commonly used for cell culture and tissue engineering applications. Collagen hydrogels replicate the nonlinear stress–strain relationship of collagenous tissue under extension. However, they buckle and soften under compression, whereas natural tissue exhibits significant stiffening due to the presence of cells and other matrix components. To more closely mimic the mechanical properties of natural tissue, varying concentrations of the basement membrane extract Matrigel are added to collagen. The stress–strain relationship of the resulting composite hydrogels is then analyzed under compression, tension, and shear. It is found that the addition of Matrigel increases the stiffness and reduces the compression‐tension asymmetry. This can be explained by a reduced degree of freedom for collagen fiber buckling due to the constraints imposed by the surrounding fine‐meshed Matrigel network. Consistent with this explanation, it is found that the collapse of composite hydrogels under uniaxial strain decreases with increasing concentration of Matrigel and other filler materials, such as alginate. Taken together, by adjusting the ratio of Matrigel to collagen, the mechanical compression‐tension asymmetry and nonlinearity of composite hydrogels can be tuned to more closely mimic natural tissue and tailor cell behavior.

17 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
NTNicole Tueni
Nicole Tueni
BRBenedikt Rauh
Benedikt Rauh
JHJan Hinrichsen
Jan Hinrichsen
SRStefan Rampp
Stefan Rampp
ADArnd Doerfler
Arnd Doerfler
SBSilvia Budday
Silvia Budday
Reliable characterization of spatial variations in brain tissue stiffness is essential for predictive biomechanical modeling, yet most current methods rely on coarse regional parameter assignments based on invasive mechanical testing. In this study, we propose a new approach to obtain subject-specific mechanical properties at voxel resolution from in vivo diffusion tensor magnetic resonance imaging (DTI) based on a linear regression between the fractional anisotropy (FA) from DTI and experimentally measured stiffness values. To assess how such heterogeneity in mechanical properties influences simulated brain deformation, we construct a finite element model based on two material parameterizations of the same human brain: one employing nine anatomically defined regions, each with uniform material parameters, and another in which the shear modulus is assigned voxel-wise on the corresponding FA value. Applying this FA-stiffness mapping yields a smoothly varying mechanical property distribution that better captures local microstructural differences not represented by region-wise parameterizations. Both parameterizations are subjected to an identical atrophy-driven loading scenario. They exhibit comparable overall volume loss, but diverge in regional behavior. The voxel-resolved parameterization predicts more pronounced ventricular expansion and differs in the displacement and stretch distributions, indicating that variability in stiffness can alter local predicted responses even when global outcomes appear similar. This work presents a pipeline for estimating individualized mechanical properties directly from imaging protocols that are routinely performed on patients, with important implications for brain biomechanics. While the approach depends on a simplified linear FA-stiffness relation and assumes isotropic constitutive behavior, it provides a framework for integrating imaging-based microstructure into subject-specific simulations. Future validation against in vivo or experimental deformation data is needed to determine the fidelity and clinical utility of FA-derived stiffness fields.

21 April 2026 in bioRxiv
Verified
Preprint
Open access
JHJan Hinrichsen
Jan Hinrichsen
NRNina Reiter
Nina Reiter
LHLucas Hoffmann
Lucas Hoffmann
JVJörg Vorndran
Jörg Vorndran
SRStefan Rampp
Stefan Rampp
SBSilvia Budday
Silvia Budday
Hippocampal sclerosis (HS) is the most common pathology in drug-resistant temporal lobe epilepsy (TLE). However, clinical diagnosis, prevalent epileptogenicity, and drug drug-resistance in individuals with HS remain an ongoing challenge demanding multidisciplinary research efforts. In this study, we examined the mechanical properties of neurosurgically en bloc resected HS specimens (n=8) ex vivo under compression, tension, and torsional shear. We fitted a two-term Ogden hyperelastic model to the measured mechanical responses to quantify nonlinear mechanical tissue properties. The resulting parameters revealed higher strain stiffening under compression in HS compared to hippocampus obtained post mortem (n=7). The distinction was most noticeable in the large-strain regime, which has important implications for using mechanical tissue properties as valuable diagnostic biomarker. Furthermore, we correlated the tissue microstructure with mechanical parameters. We trained a deep-learning histopathology classifier to detect and classify neurons and glial cells from hematoxylin-stained whole slide images (WSI). We identified a strong association between the small-strain stiffness (shear modulus µ ) and the overall cell density as well as the glial cell density. The negative relationship between the neuron-to-glia ratio and shear modulus is consistent with the hypothesis that neuronal cell loss and gliosis drives tissue stiffening, respectively. Magnetic resonance imaging (MRI) analysis of the specimens confirmed the previously reported negative association between MRI-derived fractional anisotropy and shear modulus µ . Taken together, our study establishes a direct link between tissue mechanics and microstructure, suggesting nonlinear continuum mechanics models as promising new tools for clinical diagnosis and novel research strategies.