Yongliang Li

Yongliang Li

Auto-generated profile, based on publicly available information

Yongliang Li

Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
YLY. L. Li
Y. L. Li
GXGuosheng Xu
Guosheng Xu
ZWZ. W. Wu
Z. W. Wu
BZB. Zhang
B. Zhang
LZLing Zhang
Ling Zhang
ETEast Team
East Team
Hot spots induced by lower hybrid wave in experimental advanced superconducting tokamak tokamak have caused high performance experiment disruption and serious damages to the guard limiters. Experimental and theoretical analyses have been carried out to study its physical mechanism. Plasma density scan experiments indicate that the wall temperature within the hot spots enhanced by a factor of 5 and increases with the plasma density near the antenna. A lower hybrid current drive (LHCD)-only density climb experiment shows that the carbon impurity decreases to a minimum value at certain plasma density and then increases with the line averaged plasma density. A model has been developed to explain the mechanism of sputtering of graphite tiles due to hot spots as the plasma density near the LHCD antenna and the time increases. A theoretical scaling of the heat flux driven by LHCD is also presented and is consistent with the experimental scaling in the Tore Supra tokamak. The simulation results show that the total sputtering flux density has a minimum at a certain plasma density and gradually increases as the plasma density increases or decreases away from the minimum value, and the increase in parallel heat flux near the antenna would enhance the sputtering flux density. The sputtering flux density trend is qualitatively consistent with the density scan experiments. The simulated temporal evolution of sputtered flux implies that the chemical sputtering could be a candidate for the carbon impurity explosion.

1 July 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
LCL. Chen
L. Chen
GXGuosheng Xu
Guosheng Xu
NYN. Yan
N. Yan
ANA. H. Nielsen
A. H. Nielsen
JLJ. B. Liu
J. B. Liu
ETEast Team
East Team
In this paper, we will experimentally investigate the power threshold (PL-H) in upper single null plasmas with an ITER-like tungsten divertor under different ∇B drift directions on EAST [F. Ding et al., Commissioning and PSI Behavior of the ITER-Like W/Cu Divertor in EAST 22nd PSI, Rome (2016)]. The power threshold for the low (L) to high (H) confinement mode has a clear and positive toroidal magnetic field, BT, dependence when the ∇B drift points toward the primary X-point (B×∇B↑). A factor of 2–3 increase in PL-H is observed for the ∇B drift away from the primary X-point (B×∇B↓). The edge and core impurities quantified by spectroscopy measurements show comparable levels for the transitions for both drift directions. On the other hand, it is found that the divertor Dα emission just prior to the L-H transition is lower for B×∇B↑, compared with that for B×∇B↓. The upper in-out divertor asymmetry, as manifested by particle fluxes measured by the divertor triple Langmuir probe, is most marked for B×∇B↓, and with significantly more particle flux to the outer divertor. The reversing field increases the particle flux into the upper inner and lower outer divertor, reducing the in-out asymmetry. One important distinction between the two field directions has been observed, with respect to the amplitude of the scrape-off layer (SOL) parallel flow. A dedicated experiment under similar target plasma conditions shows a lower SOL density and thus a steeper density gradient slightly inside the separatrix, where a lower PL-H is found for the B×∇B↑, compared to that for B×∇B↓. We, therefore, conclude that the field-dependent SOL plasma conditions play an important role in the transition physics.

17 September 2019 in Nuclear Fusion
Verified
Journal Article
Closed access
YLY. Li
Y. Li
MHM. Henkel
M. Henkel
YLY. Liang
Y. Liang
AKA. Knieps
A. Knieps
PDP. Drews
P. Drews
TTthe W7-X team
the W7-X team

1 August 2020 in Fusion Engineering and Design
Verified
Journal Article
Closed access
MHM. Henkel
M. Henkel
YLY. Li
Y. Li
YLY. Liang
Y. Liang
PDP. Drews
P. Drews
AKA. Knieps
A. Knieps
JCJ. Cai
J. Cai

1 May 2012
Verified
Conference Paper
Closed access
CYC. Yao
C. Yao
YLY. L. Li
Y. L. Li
BLB. T. Li
B. T. Li
HYH. Yi
H. Yi
YHY. Hu
Y. Hu
WLW. G. Li
W. G. Li
A new fault location algorithm for EHVAC mixed cable-overhead line based on fault zone identification is proposed. When the failure happened, first, according to the uniform transmission line equations, taking cable-overhead line connection point as reference, this article puts forward the fault zone identification method; then, deducts fault point positioning functions in different sections and gets the accuracy position of the fault point by searching or calculating method; finally, conducts quantitative analysis for the influence factors of the algorithm accuracy and conclusions are given. The algorithm uses two-terminal synchronous data, fast calculation speed and high precision, not affected by the failure transition resistance. Simulation shows that this method has a high reliability.

1 December 2018 in Fusion Engineering and Design
Verified
Journal Article
Closed access
YLY.L. Li
Y.L. Li
GXG.S. Xu
G.S. Xu
KTK. Tritz
K. Tritz
XLX. Lin
X. Lin
HLH. Liu
H. Liu
GHG.H. Hu
G.H. Hu