1 December 2015 in Food Bioscience
1 January 2018 in Food Technology and Biotechnology
The oxidation mechanism of all-trans-retinol (vitamin A1) and its several esters in non-aqueous, aqueous organic mixture, and pure aqueous media was investigated by cyclic voltammetry. The oxidation occurred in several irreversible steps. The calculated highest density of electrons in retinoid molecules which are delocalized over carbon atoms of the five conjugated double bonds (C5-C14) was found in the part of the molecule involved in oxidation processes. The most sensitive oxidation peak (at +0.8 V vs. Ag/AgCl) was used for development of new direct voltammetric method based on differential pulse voltammetry for the determination of retinol at carbon paste electrode modified with surfactant sodium dodecyl sulfate (CPE/SDS). The results show that 30% (by mass) of modifier SDS exhibited optimal sensitivity and shape of voltammograms. Compared to commonly used glassy carbon electrode (GCE), the CPE/SDS showed significant progress in the retinol electroanalysis. The linear ranges for retinol determination were 1.5·10-6-1.8·10-4 M for CPE/SDS and 4.4·10-6-7.0·10-4 M for GCE with the detection limits of 1.3·10-6 and 4.6·10-7 M, respectively.
1 January 2015 in Food Technology and Biotechnology
24 January 2016 in Potravinarstvo Slovak Journal of Food Sciences
The aim of this contribution was to check if adsorptive stripping differential pulse voltammetry (AdSDPV) is suitable tool for sensitive simultenous electrochemical detection of lipophilic vitamins. Retinol (vitamin A1), cholecalciferol (vitamin D3), α-tocopherol (vitamin E) and phylloquinone (vitamin K1) were selected as representatives. All electrochemical measurements were performed in two separate steps due to the lipophilic character of the analytes. In the first step, an accumulation of lipophilic vitamin on the surface of glassy carbon electrode (GCE) was done by immersing working electrode into the aqueous”‘acetonitrile solutions (50%, v/v) of each vitamin (50.0 µmol.L-1) at 400 rpm for 5 min. In the second one, differential pulse voltammetry of accumulated vitamins was performed in 0.01 mol.L-1 acetate (pH 4.5) buffer at potential step (Estep) 5 mV, potential of amplitude (Eampl) 25 mV, interval time (t) 0.1 s and scan rate (ν) 50 mV.s-1. It was observed that electrochemical behaviour of lipophilic vitamins adsorbed on surface of solid GCE in the aqueous electrolyte was very similar to those performed in organic/aqueous electrolyte in literature. Due to reversible electrochemical behaviour of vitamin K1 (phylloquinone/phyllohydroquinone redox couple), it was possible to detect all lipophilic vitamins only in one analysis. Observed values of peak potentials (Ep) were sufficiently different for their recognition which was confirmed by the analysis of real sample. The results obtained in this study showed that simultaneous determination of some lipophilic vitamins is possible requiring further optimization study. For this reason, it is necessary to understand this work as an initial step in simultaneous determination of lipophilic vitamins without application of any chromatographic technique.
20 January 2017 in Potravinarstvo Slovak Journal of Food Sciences
Adsorptive stripping voltammetry (AdSV) of retinol at solid glassy carbon electrode (GCE), carbon paste electrode (CPE) covered by thin layer of multi-wall carbon nanotubes (CPE/MWCNTs) and carbon paste electrode covered by thin layer of single layer graphene (CPE/Graphene) was compared with an extractive stripping voltammetry (ExSV) into silicone oil (SO) as lipophilic binder of glassy carbon paste electrode (GCPE). All types of selected working electrodes were characterized by a scanning electron microscopy to determine overall morphology of electrode surfaces together with spatial arrangement of used carbon particles. The retinol, also known as vitamin A1, was chosen as a model analyte because it is the most biologically active representative of retinoids which are classified as a significant group of lipophilic vitamins. Based on this comparison, it was observed that electrochemical method with high sensitivity (ExSV at GPCE) is generally characterized by shorter linear range of the calibration curve than in case of AdSV at CPE/MWCNTs or CPE/Graphene. Unlike AdSV at solid GCE, all other tested electrochemical methods could represent suitable analytical tools for monitoring of retinoids in different types of foodstuffs. Especially, content of retinol up to tenths milligrams can be easily determined using ExSV. Additionally, negative interference of chemical species present in real samples is minimal in comparison with direct voltammetric methods performed in supporting electrolytes based on organic solvents due to application of accumulation step in "ex-situ" mode.
2 February 2018 in Potravinarstvo Slovak Journal of Food Sciences
The aim of this study was describe electrochemical properties of a carbon paste electrode (CPE) bulk modified with 30% (w/w) surfactant sodium dodecyl sulphate (CPE/SDS) and demonstrates its application in the determination of α‑tocopheryl acetate (α‑TAc), known as vitamin E acetate, in selected cosmetic products, especially body creams. In addition to anionic SDS, cationic hexadecylpyridinium chloride monohydrate (CPC) was also tested as possible modifier. It was found that selection of surfactant type and its content significantly affect an electrical conductivity and mechanical stability of these heterogeneous electroanalytical sensors in pure organic solvents. Under this study, it was found that CPC is a totally inappropriate mediator due to very high backgroundcurrent. Together with other lipophilic vitamins characterized by antioxidant activity (dominantly retionoids), this completely synthetic substance is widely used as significant cosmetic additive due its preservative properties. Monitoring of its content in cosmetic products is usually performed by high‑performance liquid chromatography (HPLC) with UV detection. This standard analytical protocol is always burdened with the complex and time‑consuming preparation of the sample before analysis. For that reason, robust and simple electroanalytical method based on anodic oxidation of the α‑TAc at CPE/SDS by square wave voltammetry (SWV) performed in pure organic electrolyte (99.8% acetonitrile containing 0.1 mol·L‑1 LiClO4) was developed. Moreover, simple dissolution of sample in supporting electrolyte using ultrasonic bath and subsequent filtering through a stacked filter included all the necessary procedures for sample preparation. The linear range from 0.1 to 1.2 mmol·L‑1and limit of detection 37 µmol·L‑1 were found at pulse amplitude 10 mV and frequency 10 Hz as optimum. In analysis of selected cosmetics, the developed electroanalytical method was not validated using comparison with standard HPLC. At least, the recovery was verified by analysis of model sample and value 95.8% was calculated.