Richard M. van Hees

Richard M. van Hees

Auto-generated profile, based on publicly available information

Richard M. van Hees

SRON Netherlands Institute for Space Research, Niels Bohrweg 4, 2333 CA, Leiden, the Netherlands

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2022 in Science Advances
Verified
Journal Article
Open access
JMJoannes D. Maasakkers
Joannes D. Maasakkers
DVDaniel J. Varon
Daniel J. Varon
AEAldís Elfarsdóttir
Aldís Elfarsdóttir
JMJason McKeever
Jason McKeever
DJDylan Jervis
Dylan Jervis
IAIlse Aben
Ilse Aben
As atmospheric methane concentrations increase at record pace, it is critical to identify individual emission sources with high potential for mitigation. Here, we leverage the synergy between satellite instruments with different spatiotemporal coverage and resolution to detect and quantify emissions from individual landfills. We use the global surveying Tropospheric Monitoring Instrument (TROPOMI) to identify large emission hot spots and then zoom in with high-resolution target-mode observations from the GHGSat instrument suite to identify the responsible facilities and characterize their emissions. Using this approach, we detect and analyze strongly emitting landfills (3 to 29 t hour −1 ) in Buenos Aires, Delhi, Lahore, and Mumbai. Using TROPOMI data in an inversion, we find that city-level emissions are 1.4 to 2.6 times larger than reported in commonly used emission inventories and that the landfills contribute 6 to 50% of those emissions. Our work demonstrates how complementary satellites enable global detection, identification, and monitoring of methane superemitters at the facility level.

15 September 2021 in Nature
Verified
Journal Article
Closed access
PDF file
IVIvar R. van der Velde
Ivar R. van der Velde
GWGuido R. van der Werf
Guido R. van der Werf
SHSander Houweling
Sander Houweling
JMJoannes D. Maasakkers
Joannes D. Maasakkers
Tobias BorsdorffTobias Borsdorff
Tobias Borsdorff
IAIlse Aben
Ilse Aben

17 February 2025 in Geophysical Research Letters
Verified
Journal Article
Open access
GFGuangliang Fu
Guangliang Fu
JRJeroen Rietjens
Jeroen Rietjens
RLRaul Laasner
Raul Laasner
LSLaura van der Schaaf
Laura van der Schaaf
RHRichard van Hees
Richard van Hees
OHOtto Hasekamp
Otto Hasekamp
We present the first Spectropolarimeter for Planetary EXploration ‐ one (SPEXone) aerosol retrieval results over land and ocean using the Remote sensing of Trace gas and Aerosol Products algorithm, covering the period 23 February–31 August 2024. We validate the retrieved Aerosol Optical Depth (AOD), Angstrom Exponent (AE), and Single Scattering Albedo (SSA) with AErosol RObotic NETwork (AERONET) data. The validation results show that SPEXone provides products of good quality, with comparable performance over land and ocean. For AOD, the Root‐Mean‐Square Error (RMSE) is 0.053 over land and 0.043 over ocean, while respectively 77% and 75% of the retrievals are within the requirement formulated by the Global Climate Observing System (GCOS). For AE, the RMSE is 0.25 over land and 0.26 over ocean. For SSA, the RMSE is 0.036 over land and 0.036 over ocean, with respectively 69% and 69.4% within the GCOS requirement. After a gap of more than 10 years, this is the first new global Multi‐Angle Polarimeter aerosol dataset.

4 July 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RHRichard M. van Hees
Richard M. van Hees
PTPaul J. J. Tol
Paul J. J. Tol
SCSidney Cadot
Sidney Cadot
MKMatthijs Krijger
Matthijs Krijger
SPStefan Persijn
Stefan Persijn
RHRuud W. M. Hoogeveen
Ruud W. M. Hoogeveen
The Tropospheric Monitoring Instrument (TROPOMI) is the single instrument on board the ESA Copernicus Sentinel-5 Precursor satellite. TROPOMI is a nadir-viewing imaging spectrometer with bands in the ultraviolet and visible, the near infrared and the shortwave infrared (SWIR). An accurate instrument spectral response function (ISRF) is required in the SWIR band where absorption lines of CO, methane and water vapor overlap. In this paper, we report on the determination of the TROPOMI-SWIR ISRF during an extensive on-ground calibration campaign. Measurements are taken with a monochromatic light source scanning the whole detector, using the spectrometer itself to determine the light intensity and wavelength. The accuracy of the resulting ISRF calibration key data is well within the requirement for trace-gas retrievals. Long-term in-flight monitoring of SWIR ISRF is achieved using five on-board diode lasers.

27 July 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
PTPaul J. J. Tol
Paul J. J. Tol
TKTim A. van Kempen
Tim A. van Kempen
RHRichard M. van Hees
Richard M. van Hees
MKMatthijs Krijger
Matthijs Krijger
SCSidney Cadot
Sidney Cadot
RHRuud W. M. Hoogeveen
Ruud W. M. Hoogeveen
The shortwave infrared (SWIR) spectrometer module of the Tropospheric Monitoring Instrument (TROPOMI), on board the ESA Copernicus Sentinel-5 Precursor satellite, is used to measure atmospheric CO and methane columns. For this purpose, calibrated radiance measurements are needed that are minimally contaminated by instrumental stray light. Therefore, a method has been developed and applied in an on-ground calibration campaign to characterize stray light in detail using a monochromatic quasi-point light source. The dynamic range of the signal was extended to more than 7 orders of magnitude by performing measurements with different exposure times, saturating detector pixels at the longer exposure times. Analysis of the stray light indicates about 4.4 % of the detected light is correctable stray light. An algorithm was then devised and implemented in the operational data processor to correct in-flight SWIR observations in near-real time, based on Van Cittert deconvolution. The stray light is approximated by a far-field kernel independent of position and wavelength and an additional kernel representing the main reflection. Applying this correction significantly reduces the stray-light signal, for example in a simulated dark forest scene close to bright clouds by a factor of about 10. Simulations indicate that this reduces the stray-light error sufficiently for accurate gas-column retrievals. In addition, the instrument contains five SWIR diode lasers that enable long-term, in-flight monitoring of the stray-light distribution.

20 December 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
TKTim A. van Kempen
Tim A. van Kempen
RHRichard M. van Hees
Richard M. van Hees
PTPaul J. J. Tol
Paul J. J. Tol
IAIlse Aben
Ilse Aben
RHRuud W. M. Hoogeveen
Ruud W. M. Hoogeveen
During its first year in operation the short-wave infrared (SWIR) Tropospheric Monitoring Instrument (TROPOMI) was calibrated in-flight and its performance was monitored. In this paper we present the results of the in-flight calibration and the ongoing instrument monitoring. This includes the determination of the background signals, noise performance, instrument spectral response function (ISRF) stability, and stray-light stability. From these results, the number of incurred dead and bad pixels due to cosmic-ray impacts is determined. The light-path transmission is checked by monitoring internal lamp and diffuser stabilities. Due to its high sensitivity to Earth radiation on the eclipse side, the calibration strategy for the background (i.e. dark current and offset) monitoring was adjusted. Trends over the first full year of nominal operations reveal a very stable SWIR module. The number of newly incurred dead and bad pixels is less than 0.1 % over nearly a full year since the start of operations. Assuming linear degradation of various components, the SWIR module is expected to keep performing within expected parameters for the full operational lifetime.