A quantitative and confirmatory high-performance liquid chromatography with ultraviolet detection (HPLC–UV) method for the determination of bioactive amines in the albumen and yolk of commercial eggs was developed, optimized and validated by analyte extraction with trichloroacetic acid and pre-column derivatization with dansyl chloride. Phenylethylamine, putrescine, cadaverine, histamine, tyramine, spermidine and spermine standards were used to evaluate the following performance parameters: limit of detection (LoD), limit of quantification (LoQ), selectivity, linearity, precision, recovery and ruggedness. The LoD of the method was defined from 0.2 to 0.3mgkg−1 for the yolk matrix and from 0.2 to 0.4mgkg−1 for the albumen matrix; the LoQ was from 0.7 to 1.0mgkg−1 for the yolk matrix and from 0.7 to 1.1mgkg−1 for the albumen matrix. The validated method exhibited excellent selectivity and separation of all amines with coefficients of determination higher than 0.99. The obtained recovery values were from 90.5% to 108.3%, and the relative standard deviation (RSD) was lower than 10% under repeatability conditions for the studied analytes. The performance parameters show the validated method to be adequate for the determination of bioactive amines in egg albumen and yolk
Carbadox (CBX) and olaquindox (OLA) were used in poultry and swine feed for growth promotion, to improve feed efficiency and increase the rate of weight gain. However, the use of these agents in feedingstuffs was prohibited because of concerns about their toxicity. Regulatory laboratories are required to have suitably validated analytical methods to ensure compliance with the ban. A quantitative and confirmatory method for determining the presence of CBX and OLA in poultry and swine feed by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was developed, optimized, and validated. The analytes extraction was performed with a mixture of water and acetonitrile (1:1v/v) and cleanup with hexane and C18 (dispersive phase). The method was evaluated by the following parameters: specificity, linearity, matrix effect, decision limits (CCα), detection capability (CCβ), accuracy, precision, limits of detection (LoD), limits of quantification (LoQ) and measurement uncertainty. The validated method presented a broad linear study range and no significant matrix effect. The limit of detection (LoD) was defined at 9 μg kg(-1) for CBX and 80 μg kg(-1) for OLA, and the limit of quantification (LoQ) was defined at 12 μg kg(-1) and 110 μg kg(-1) for CBX and OLA, respectively. The accuracy of the method was adequate for CBX and OLA. The recovery values found in the repeatability conditions were 99.41% for CBX and 104.62% for OLA. Under intralaboratory reproducibility conditions, the values were 98.63% for CBX and 95.07% for OLA. It was concluded that the performance parameters demonstrated total method adequacy for the detection and quantification of CBX and OLA in poultry and swine feedingstuffs.