Hui Li

Hui Li

Auto-generated profile, based on publicly available information

Hui Li

Laboratory of Advanced Theranostic Materials and Technology Ningbo Institute of Materials Technology and Engineering Chinese Academy of Sciences Ningbo China

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Light: Science & Applications
Verified
Journal Article
Open access
PDF file
GWGang Wen
Gang Wen
SLSimin Li
Simin Li
LWLinbo Wang
Linbo Wang
XCXiaohu Chen
Xiaohu Chen
Zhenglong SunZhenglong Sun
Zhenglong Sun
HLHui Li
Hui Li
Structured illumination microscopy (SIM) has become a widely used tool for insight into biomedical challenges due to its rapid, long-term, and super-resolution (SR) imaging. However, artifacts that often appear in SIM images have long brought into question its fidelity, and might cause misinterpretation of biological structures. We present HiFi-SIM, a high-fidelity SIM reconstruction algorithm, by engineering the effective point spread function (PSF) into an ideal form. HiFi-SIM can effectively reduce commonly seen artifacts without loss of fine structures and improve the axial sectioning for samples with strong background. In particular, HiFi-SIM is not sensitive to the commonly used PSF and reconstruction parameters; hence, it lowers the requirements for dedicated PSF calibration and complicated parameter adjustment, thus promoting SIM as a daily imaging tool.

28 April 2023 in Nanoscale
Verified
Journal Article
Closed access
PDF file
Cong ChenCong Chen
Cong Chen
XLXiaoyin Li
Xiaoyin Li
GYGang Yang
Gang Yang
XCXiaohu Chen
Xiaohu Chen
SLShoupeng Liu
Shoupeng Liu
HLHui Li
Hui Li
Computational hyperspectral devices that use artificial filters have shown promise as compact spectral devices. However, the current designs are restricted by limited types and geometric parameters of unit cells, resulting in a high cross-correlation between the transmission spectra. This limitation prevents the fulfillment of the requirement for compressed-sensing-based spectral reconstruction. To address this challenge, we proposed and simulated a novel design for computational hyperspectral devices based on quasi-random metasurface supercells. The size of the quasi-random metasurface supercell was extended above the wavelength, which enables the exploration of a larger variety of symmetrical supercell structures. Consequently, more quasi-random supercells with lower polarization sensitivity and their spectra with low cross-correlation were obtained. Devices for narrowband spectral reconstruction and broadband hyperspectral single-shot imaging were designed and fabricated. Combined with the genetic algorithm with compressed sensing, the narrowband spectral reconstruction device reconstructs the complex narrowband hyperspectral signal with 6 nm spectral resolution and ultralow errors. The broadband hyperspectral device reconstructs a broadband hyperspectral image (λ/λ ∼ 0.001) with a high average signal fidelity of 92%. This device has the potential to be integrated into a complementary metal–oxide–semiconductor (CMOS) chip for single-shot imaging.

15 June 2023 in PhotoniX
Verified
Journal Article
Open access
PDF file
GWGang Wen
Gang Wen
SLSimin Li
Simin Li
YLYong Liang
Yong Liang
LWLinbo Wang
Linbo Wang
JZJie Zhang
Jie Zhang
HLHui Li
Hui Li
Super-resolution structured illumination microscopy (SR-SIM) has become a widely used nanoscopy technique for rapid, long-term, and multi-color imaging of live cells. Precise but troublesome determination of the illumination pattern parameters is a prerequisite for Wiener-deconvolution-based SR-SIM image reconstruction. Here, we present a direct reconstruction SIM algorithm (direct-SIM) with an initial spatial-domain reconstruction followed by frequency-domain spectrum optimization. Without any prior knowledge of illumination patterns and bypassing the artifact-sensitive Wiener deconvolution procedures, resolution-doubled SR images could be reconstructed by direct-SIM free of common artifacts, even for the raw images with large pattern variance in the field of view (FOV). Direct-SIM can be applied to previously difficult scenarios such as very sparse samples, periodic samples, very small FOV imaging, and stitched large FOV imaging.

1 August 2012 in Plasma Science and Technology
Verified
Journal Article
Closed access
XTXiaoping Tao
Xiaoping Tao
RLRongde Lu
Rongde Lu
HLHui Li
Hui Li

20 November 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LWLinbo Wang
Linbo Wang
SLSimin Li
Simin Li
Zhenglong SunZhenglong Sun
Zhenglong Sun
GWGang Wen
Gang Wen
FZFan Zheng
Fan Zheng
HLHui Li
Hui Li
Phenotype analysis of yeast cell requires high-throughput imaging and automatic analysis of abundant image data. At first, each cell needs to be segmented and labeled in the bright-field images. However, the ambiguous boundary of bright-field yeast cell images leads to the failure of traditional segmentation algorithms. We propose a segmentation algorithm based on the morphological characteristics of yeast cells. Seed points are first identified along the cell contour and then connected by an edge tracing approach. In this way, “ill-detected” noise points are removed so that edges of yeast cells can be successfully extracted in bright-field images with sparsely distributed cells. In densely packed images, yeast cells with normal morphology can also be correctly segmented and labeled.

30 January 2020 in Biomedical Optics Express
Verified
Journal Article
Closed access
CCChen Chong
Chen Chong
LSLi Simin
Li Simin
WGWen Gang
Wen Gang
LYLiang Yong
Liang Yong
WLWang Linbo
Wang Linbo
LHLi Hui
Li Hui
We established a four-dimensional (4D) microscopy method using structured illumination for optical axial imaging with an electrically tunable lens. With its fast imaging capability, the dynamics of the cardiovascular system of the zebrafish and cerebral vessels were imaged based on the coverage of two stacks (25 layers) per second with lateral /axial resolutions of 0.6 µm and 1.8 µm, respectively. Time lapse imaging clearly shows the contractile–relaxation response of the beating heart at different cardiac phases and with different mobilities of blood vessels in different regions. This new 4D technique will facilitate in vivo imaging of organ function, generation, as well as drug responses in small-sized animals.