1 November 2018 in Engineering Structures
23 November 2018 in Advances in Structural Engineering
The majority of existing ancient timber structures have different degrees of damage. The looseness of mortise-tenon joints is a kind of typical damage type. In order to study the influence of looseness on the seismic performance of mortise-tenon joints, six through-tenon joints and six dovetail-tenon joints with scale 1:3.2 were fabricated according to the requirements of the engineering fabrication method of Chinese Qing Dynasty. Each type of joints consisted of one intact joint and five artificial loose joints, and the artificial defect was made to simulate looseness by cutting the tenon sectional dimension. Based on experiments of two types of joints under low-cyclic reversed loading, the seismic behaviors of joints such as failure modes, hysteretic loops and skeleton curves, strength and stiffness degradation, and energy dissipation capacity were studied. Moreover, the comparative analyses of seismic performance between two types of joints were carried out. The variation tendency of seismic behaviors of two types of joints has similarities, and there are some differences due to their different structural styles. The results indicate that squeeze deformation between tenon and mortise of two types of joints occurred. The shape of hysteretic loops of two types of joints is reverse-Z-shape, and the pinching effect of hysteretic loops becomes more obvious with the increase in looseness, among which of through-tenon joints is more obvious than that of dovetail-tenon joints. The carrying capacity, stiffness, and energy dissipation capacity of loose joints are significantly lower than that of the intact one, and the energy dissipation capacity of dovetail-tenon joints is better than that of through-tenon joints. The rotation angles of two types of joints can reach 0.12 rad, and the loose joints still have great deformation capacity.
8 February 2019 in Advances in Structural Engineering
A half-scale model of a two-story and two-span column-and-tie wooden structure was fabricated and tested on the shaking table to assess the seismic behavior of the structure under various base input intensities. The dynamic characteristics, acceleration response, displacement response and shear force distributions were measured and assessed. Besides, the cumulative hysteretic energy dissipation performance of the model was analyzed. The test results revealed that with the increasing magnitude of earthquake excitation, the natural frequency and stiffness of the model structure decreased, and the damping ratio increased. The acceleration amplification factor of each layer fluctuated between 0.286 and 1.383. The wooden house is directly placed on the concrete slab, which to some extent plays a role in sliding isolation. The model dissipates seismic energy mainly by the first layer. When the earthquake excitation was 0.22g and 0.40g, the model responded seriously, and the maximum inter-story drifts of the model was 1/65 and 1/35, respectively. When the earthquake input reached 0.5g, the structure did not collapse. This demonstrates that the wooden structure has strong capability of lateral resistance and deformation resistance. Furthermore, the wooden wallboard component acts as the first seismic line under earthquake excitation, meeting the characteristics of “A wall falls down, while the house will not collapse.” This article can help guide the seismic design and performance assessment of traditional wooden constructions.