Ferenc Bereczki

Ferenc Bereczki

Auto-generated profile, based on publicly available information

Ferenc Bereczki

In Silico Biomechanics Laboratory, National Center for Spinal Disorders, Buda Health Center, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2025 in European Spine Journal
Verified
Journal Article
Open access
PDF file
BHBenjamin Hajnal
Benjamin Hajnal
APAgoston Jakab Pokorni
Agoston Jakab Pokorni
MTMáté Turbucz
Máté Turbucz
FBFerenc Bereczki
Ferenc Bereczki
MBMarton Bartos
Marton Bartos
PÉPéter Éltes
Péter Éltes
Purpose: The objective of this systematic review is to present a comprehensive summary of existing research on the use of 3D printing in spinal surgery. Methods: The researchers conducted a thorough search of four digital databases (PubMed, Web of Science, Scopus, and Embase) to identify relevant studies published between January 1999 and December 2022. The review focused on various aspects, including the types of objects printed, clinical applications, clinical outcomes, time and cost considerations, 3D printing materials, location of 3D printing, and technologies utilized. Out of the 1620 studies initially identified and the 17 added by manual search, 105 met the inclusion criteria for this review, collectively involving 2088 patients whose surgeries involved 3D printed objects. Results: The studies presented a variety of 3D printed devices, such as anatomical models, intraoperative navigational templates, and customized implants. The most widely used type of objects are drill guides (53%) and anatomical models (25%) which can also be used for simulating the surgery. Custom made implants are much less frequently used (16% of papers). These devices significantly improved clinical outcomes, particularly enhancing the accuracy of pedicle screw placement. Most studies (88%) reported reduced operation times, although two noted longer times due to procedural complexities. A variety of 3DP technologies and materials were used, with STL, FDM, and SLS common for models and guides, and titanium for implants via EBM, SLM, and DMLS. Materialise software (Mimics, 3-Matic, Magics) was frequently utilized. While most studies mentioned outsourced production, in-house printing was implied in several cases, indicating a trend towards localized 3D printing in spine surgery. Conclusions: 3D printing in spine surgery, a rapidly growing area of research, is predominantly used for creating drill guides for screw insertion, anatomical models, and innovative implants, enhancing clinical outcomes and reducing operative time. While cost-efficiency remains uncertain due to insufficient data, some 3D printing applications, like pedicle screw drill guides, are already widely accepted and routinely used in hospitals.

1 May 2021 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
PÉPéter Éltes
Péter Éltes
LKLaszlo Kiss
Laszlo Kiss
FBFerenc Bereczki
Ferenc Bereczki
ZSZsolt Szoverfi
Zsolt Szoverfi
CTChloé Techens
Chloé Techens
ALAron Lazary
Aron Lazary
Percutaneous cement discoplasty (PCD) is a minimally invasive surgical option to treat patients who suffer from the consequences of advanced disc degeneration. As the current two-dimensional methods can inappropriately measure the difference in the complex 3D anatomy of the spinal segment, our aim was to develop and apply a volumetric method to measure the geometrical change in the surgically treated segments. Prospective clinical and radiological data of 10 patients who underwent single- or multilevel PCD was collected. Pre- and postoperative CT scan-based 3D reconstructions were performed. The injected PMMA (Polymethylmethacrylate) induced lifting of the cranial vertebra and the following volumetric change was measured by subtraction of the geometry of the spinal canal from a pre- and postoperatively predefined cylinder. The associations of the PMMA geometry and the volumetric change of the spinal canal with clinical outcome were determined. Change in the spinal canal volume (ΔV) due to the surgery proved to be significant (mean ΔV = 2266.5 ± 1172.2 mm3, n = 16; p = 0.0004). A significant, positive correlation was found between ΔV, the volume and the surface of the injected PMMA. A strong, significant association between pain intensity (low back and leg pain) and the magnitude of the volumetric increase of the spinal canal was shown (ρ = 0.772, p = 0.009 for LBP and ρ = 0.693, p = 0.026 for LP). The developed method is accurate, reproducible and applicable for the analysis of any other spinal surgical method. The volume and surface area of the injected PMMA have a predictive power on the extent of the indirect spinal canal decompression. The larger the ΔV the higher clinical benefit was achieved with the PCD procedure. The developed method has the potential to be integrated into clinical software’s to evaluate the efficacy of different surgical procedures based on indirect decompression effect such as PCD, anterior lumbar interbody fusion (ALIF), lateral lumbar interbody fusion (LLIF), oblique lumbar interbody fusion (OLIF), extreme lateral interbody fusion (XLIF). The intraoperative use of the method will allow the surgeon to respond if the decompression does not reach the desired level.

1 February 2024 in The Spine Journal
Verified
Journal Article
Open access
FBFerenc Bereczki
Ferenc Bereczki
MTMáté Turbucz
Máté Turbucz
APAgoston Jakab Pokorni
Agoston Jakab Pokorni
BHBenjamin Hajnal
Benjamin Hajnal
MRMarton Ronai
Marton Ronai
PÉPéter Éltes
Péter Éltes
Oblique lumbar interbody fusion (OLIF) can provide an ideal minimally invasive solution for achieving spinal fusion in an older, more frail population where decreased bone quality can be a limiting factor. Stabilization can be achieved with bilateral pedicle screws (BPS), which require additional incisions and longer operative time. Alternatively, a novel self-anchoring stand-alone lateral plate system (SSA) can be used, where no additional incisions are required. Based on the relevant literature, BPS constructs provide greater primary biomechanical stability compared to lateral plate constructs, including SSA. This difference is further increased by osteoporosis. Screw augmentation in spinal fusion surgeries is commonly used; however, in the case of OLIF, it is a fairly new concept, lacking a consensus-based guideline. This comparative finite element (FE) study aimed to investigate the effect of PMMA screw augmentation on the primary stability of a stand-alone implant construct versus posterior stabilization in OLIF with osteoporotic bone quality. The biomechanical effect of screw augmentation was studied inside an in-silico environment using computer-aided FE analysis. A previously validated and published L2-L4 FE model with normal and osteoporotic bone material properties was used. Geometries based on the OLIF implants (BPS, SSA) were created and placed inside the L3-L4 motion segment with increasing volumes (1-6 cm3) of PMMA augmentation. A follower load of 400 N and 10 Nm bending moment (in the three anatomical planes) were applied to the surgical FE models with different bone material properties. The operated L3-L4 segmental range of motion (ROM), the inserted cage's maximal caudal displacements, and L4 cranial bony endplate principal stress values were measured. The nonaugmented values for the BPS construct were generally lower compared to SSA, and the difference was increased by osteoporosis. In osteoporotic bone, PMMA augmentation gradually decreased the investigated parameters and the difference between the two constructs as well. Between 3 cm3 and 4 cm3 of injected PMMA volume per screw, the difference between augmented SSA and standard BPS became comparable. Based on this study, augmentation can enhance the primary stability of the constructs and decrease the difference between them. Considering leakage as a possible complication, between 3 cm3 and 4 cm3 of injected PMMA per screw can be an adequate amount for SSA augmentation. However, further in silico, and possibly in vitro and clinical testing is required to thoroughly understand the investigated biomechanical aspects. This study sheds light on the possible biomechanical advantage offered by augmented OLIF implants and provides a theoretical augmentation amount for the SSA construct. Based on the findings, the concept of an SSA device with PMMA augmentation capability is desirable.

1 January 2022 in Kaleidoscope History
Verified
Journal Article
Open access
MTMáté Turbucz
Máté Turbucz
FBFerenc Bereczki
Ferenc Bereczki
BHBenjámin Hajnal
Benjámin Hajnal
APAgoston Jakab Pokorni
Agoston Jakab Pokorni
PVPéter Pál Varga
Péter Pál Varga
PÉPéter Éltes
Péter Éltes