Bareld Wit

Bareld Wit

Auto-generated profile, based on publicly available information

Bareld Wit

Institute of Semiconductor and Solid State Physics, Johannes Kepler University Linz 1 , 4040 Linz, Austria

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2015 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
SHSam Haq
Sam Haq
BWBareld Wit
Bareld Wit
HSHongqian Sang
Hongqian Sang
Andrea FlorisAndrea Floris
Andrea Floris
Yu WangYu Wang
Yu Wang
RRRasmita Raval
Rasmita Raval

12 June 2019 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
KSKnud Seufert
Knud Seufert
FMFiona McBride
Fiona McBride
SJSimon Jaekel
Simon Jaekel
BWBareld Wit
Bareld Wit
SHSam Haq
Sam Haq
LGLeonhard Grill
Leonhard Grill

18 July 2011 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SPS. Parui
S. Parui
BWB. Wit
B. Wit
BLBignardi Luca
Bignardi Luca
Petra RudolfPetra Rudolf
Petra Rudolf
BKB. Kooi
B. Kooi
TBT. Banerjee
T. Banerjee
We have investigated hot electron transmission across epitaxial metal-disilicide/n-Si(111) interfaces using ballistic electron emission microscopy (BEEM). Different crystal orientations of epitaxial NiSi2 were grown on a Si(111) substrate using molecular beam epitaxy. The presence of different interfaces of NiSi2 on Si(111) were confirmed by high resolution transmission electron microscopy. Electrical transport measurements reveal a clear rectifying Schottky interface with a barrier height of 0.69 eV. However, using BEEM, three different regions with different transmissions and Schottky barrier heights of 0.65 eV, 0.78 eV, and 0.71 eV are found. The addition of a thin Ni film on the NiSi2 layer strongly reduces the transmission in all the three regions and interestingly, almost equalizes the transmission across them.

14 May 2020 in Advanced Materials Interfaces
Verified
Journal Article
Open access
PDF file
BWBareld Wit
Bareld Wit
OBOle Bunjes
Ole Bunjes
MWMartin Wenderoth
Martin Wenderoth
CRClaus Ropers
Claus Ropers
The structure of a physisorbed sub‐monolayer of 1,2‐bis(4‐pyridyl)ethylene (bpe) on epitaxial graphene is investigated by low‐energy electron diffraction and scanning tunneling microscopy. Additionally, nonequilibrium heat‐transfer between bpe and the surface is studied by ultrafast low‐energy electron diffraction. Bpe arranges in an oblique unit cell which is not commensurate with the substrate. Six different rotational and/or mirror domains, in which the molecular unit cell is rotated by 28 ± 0.1° with respect to the graphene surface, are identified. The molecules are weakly physisorbed, as evidenced by the fact that they readily desorb at room temperature. At liquid nitrogen temperature, however, the layers are stable and time‐resolved experiments can be performed. The temperature changes of the molecules and the surface can be measured independently through the Debye–Waller factor of their individual diffraction features. Thus, the heat flow between bpe and the surface can be monitored on a picosecond timescale. The time‐resolved measurements, in combination with model simulations, show the existence of three relevant thermal barriers between the different layers. The thermal boundary resistance between the molecular layer and graphene is found to be 2 ± 1 × 10−8 K m2 W−1.

1 April 2021 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
SFSimon Feigl
Simon Feigl
RVRadovan Vranik
Radovan Vranik
BWBareld Wit
Bareld Wit
SMStefan Müllegger
Stefan Müllegger
Radio-frequency (rf) scanning tunneling microscopy has recently been advanced to methods such as single-atom spin resonance. Such methods benefit from a frequency-independent rf voltage amplitude across the tunnel junction, which is challenging to achieve due to the strong frequency dependence of the rf attenuation in a transmission line. Two calibration methods for the rf amplitude have been reported to date. In this Note, we present an alternative method to achieve a frequency-independent rf voltage amplitude across the tunnel junction and show the results of this calibration. The presented procedure is applicable to devices that can deliver rf voltage to a tunnel junction.

13 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
BWBareld Wit
Bareld Wit
RVRadovan Vranik
Radovan Vranik
SMStefan Müllegger
Stefan Müllegger
Diverse spectroscopic methods operating at radio frequency depend on a reliable calibration to compensate for the frequency dependent damping of the transmission lines. Calibration may be impeded by the existence of a sensitive interdependence of two or more experimental parameters. Here, we show by combined scanning tunnelling microscopy measurements and numerical simulations how a frequency-dependent conductance response is affected by different DC conductance behaviours of the tunnel junction. Distinct and well-defined DC-conductance behaviour is provided by our experimental model systems, which include C60 molecules on Au(111), exhibiting electronic configurations distinct from the well-known dim and bright C60’s reported so far. We investigate specific combinations of experimental parameters. Variations of the modulation amplitude as small as only a few percent may result in systematic conductance deviations as large as one order of magnitude. We provide practical guidelines for calibrating respective measurements, which are relevant to RF spectroscopic measurements.