Ahmed Abdrabou

Ahmed Abdrabou

Auto-generated profile, based on publicly available information

Ahmed Abdrabou

Faculty of Medicine, Ain Shams University, Madinaty, Cairo, Egypt

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
AOAhmed M. Osman
Ahmed M. Osman
AAAhmed Abdrabou
Ahmed Abdrabou
ObjectiveTo evaluate the feasibility of MSCT angiography of the celiac trunk and hepatic artery variants with a non-tailored protocol among Egyptian patients.Patients and methods1285 Egyptian patients were retrospectively analyzed in our Radiology Department – Ain Shams University came for triphasic CT or CT aortic angiography. The celiac trunk origin and its main branches mainly the common hepatic artery were identified. The incidence of different celiac and hepatic artery anomalies was calculated depending on Uflacker’s and Michel’s classifications.ResultsAbout 90.5% of the patients showed normal trifurcation pattern of the celiac trunk (Uflacker type I) with the commonest variant was gastro-splenic trunk (Uflacker type V) with 4.3% incidence. The bifurcation pattern was representing 7.7% of cases. Regarding the hepatic artery, 74.3% of the cases showed normal origin of the hepatic arteries (Michel type I) with the commonest anomaly was Michel type III with 12.5% incidence. Some cases are discovered not previously described by either Uflacker’s or Michel’s classifications.ConclusionIn our preliminary reports, Good imaging quality of MSCT angiography has proved effectiveness in depicting different celiac trunk and hepatic artery variants. This is important pre-interventional or pre-surgical to decrease the complications and the morbidity rates

1 September 2014 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
KAKhaled A. Ahmad
Khaled A. Ahmad
AAAhmed Abdrabou
Ahmed Abdrabou
PurposeTo highlight the role of ADC value measurement in differentiating benign from malignant ovarian tumors.Materials and methodsTwenty patients with ovarian neoplasms underwent conventional MRI including ADC value calculation before surgery. Retrospective analysis of the pathological specimen with lesion morphology, signal characteristics, enhancement criteria and correlation with the appearance at DWI followed by ADC value measurement were obtained.ResultsTwenty patients with ovarian mass lesions were included. They were divided into purely solid, purely cystic and complex solid/cystic lesions. All solid malignant lesions showed diffusion restriction as well as the wall and septations of most malignant cystic lesion however, except one case. All benign lesions did not display diffusion restriction in DWI. The best cut off value of ADC to discriminate between benign and malignant lesions was 0.9 with specificity of 100%, sensitivity of 88.9%, NPV of 75%, PPV of 100% and accuracy of 91.7%.ConclusionAddition of ADC value measurement to conventional MRI increases its specificity from 78.6% to 85.7% which could be useful in differentiating benign from malignant lesions

1 March 2016 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
LHLobna A.M. Habib
Lobna A.M. Habib
AAAhmed M. Abdrabou
Ahmed M. Abdrabou
EGEman A.S. Geneidi
Eman A.S. Geneidi
YSYousra M. Sultan
Yousra M. Sultan
To evaluate the role of ultrasound elastography as an additional technique in differentiating US indeterminate thyroid nodules in order to decrease the number of tissue biopsies. We evaluated 30 patients with 36 indeterminate thyroid nodules based on US, criteria, by US elastography, using both the elastography score and strain ratio. Baseband US data were downloaded for off-line analysis. Elastographic maps (color coding) and thyroid stiffness index (strain ratio) were calculated for all nodules, with histopathological results being the standard reference. Receiver operating characteristic (ROC) curve analysis was used to determine the optimal cutoff strain ratio for separating benign and malignant thyroid nodules. Malignant nodules had a higher degree of color and strain ratio compared to benign nodules, with a statistically significant difference (p < 0.05). Nodules with an elastography score of 2 were benign, while those with an elastography score of 4 and 5 were mostly malignant. Malignancy could not be excluded using ultrasound elastography criteria only, in nodules with a score of 3. The sensitivity and specificity of the US-elastography strain color coding for thyroid cancer diagnosis were 91% and 72% respectively. Using ROC analysis, the optimal cutoff strain ratio for separating benign and malignant thyroid nodules was found to be 1.6 with a calculated 89% sensitivity and 70% specificity. The overall accuracy of strain color was slightly better than strain ratio, 91% compared to 86% respectively. Ultrasound elastography is an easy, non-invasive and rapid technique that can be routinely used in thyroid US scans to select cases for FNAC, and decrease the number of unnecessary biopsies, and consequently decrease the hazards and costs. However, future advances in image acquisition and reconstruction algorithms are required to improve the image quality and clinical usefulness of this technique.

1 December 2017 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
AAAhmed M. Abdrabou
Ahmed M. Abdrabou
MSMennatallah H. Shalaby
Mennatallah H. Shalaby
To highlight the relationship between coraco-humeral distance and subscapularis tendon tear. Sixty-two shoulder MRI studies were examined. Twenty-two patients had partial or complete tear of subscapularis tendon and forty shoulder as a control group. Axial and oblique sagittal MR images were examined to measure the coraco-humeral distance followed by statistical analysis to correlate the distance with tendon tear. A cut-off value of 8.25 mm for the coraco-humeral distance gave a sensitivity of 77.5% and specificity of 72.7% for subscapularis tendon tear. There is a well-known relationship between the coraco-humeral distance and the subscapularis tendon tear and its meticulous assessment in subjects with pain in the anterior shoulder region increases the diagnosis of subcoracoid impingement.

1 April 2021 in Egyptian Journal of Radiology and Nuclear Medicine
Verified
Journal Article
Open access
PDF file
AAAhmed M. Abdrabou
Ahmed M. Abdrabou
Background: Ptosis can be a manifestation of a more serious situation. Hence, the analysis of the complaint and the search for etiology are crucial in such cases. Ptosis has many causes; some of them lead to unilateral ptosis while others cause bilateral ptosis. For instance, myasthenia gravis is a cause of bilateral ptosis while oculomotor nerve palsy induces unilateral disease. Proper evaluation of the patient and identification of the cause are important to achieve accurate management and good prognosis. Case presentation: A 47-year-old male patient attended the ER complaining of dropping the right eye lid of 2 days’ duration. There was no associated pain or diplopia. On examination, the extraocular muscles’ (EOM) motility was intact, normal pupil and corneal reflexes, and there was swelling of the upper eyelid. Ophthalmological examination revealed normal anterior and posterior chambers as well as the vitreous and retina. The patient had a previous history of traumatic intracranial hemorrhage that was resolved without surgical intervention. He also had diabetes mellitus and hypertension. The patient was transferred to the MRI unit to perform MRI study of the brain and orbit with MRA and IV contrast administration. MRI findings confirmed the diagnosis of LPS myositis, and the patient received medical treatment and improved. Conclusion: Proper radiological diagnosis leads to accurate management and achieves rapid recovery and optimal patient care.

18 February 2025 in Japanese Journal of Radiology
Verified
Journal Article
Open access
PDF file
AAAhmed Abdrabou
Ahmed Abdrabou
AOAhmed M. Osman
Ahmed M. Osman
NTNoha M. Taha
Noha M. Taha
EDEman A. F. Darwish
Eman A. F. Darwish
Purpose: To determine the diagnostic merit of using quantitative imaging parameters measured on non-contrast CT (NCCT) in the diagnosis of cerebral venous thrombosis (CVT). Materials and methods: 43 patients with CVT and 30 age and sex-matched controls were enrolled in this retrospective study. Two blinded neuroradiologists independently assessed the NCCT scans for direct and indirect signs of CVT. Absolute attenuation values of thrombosed and non-thrombosed sinuses were measured and the ratio of sinus attenuation to patient’s hematocrit (H/H ratio) was calculated for each case. The attenuation value of the internal carotid artery was also measured to calculate the veno-arterial (V/A) difference. Inter-reader agreement was evaluated and all measurements were compared between patient and control groups. Results: The sensitivity and specificity of the dense sinus sign for diagnosis of CVT ranged from 72 to 79% and from 83 to 87% respectively. Sinus attenuation, H/H ratio and V/A difference were significantly higher in the CVT group than in the control group (P < 0.0001). An attenuation threshold value of > 55 HU yielded a sensitivity of 86% and a specificity of 90% and had the largest AUC of 0.89 (95%CI 0.795–0.951) among all stand-alone parameters, while the combination of an attenuation value greater than 55, or a V/A difference greater than 22, yielded the best diagnostic performance among all the parameters with sensitivity and specificity at values of 86% and a 100% respectively and an AUC of 0.93 (95%CI 0.846 to 0.977). Conclusions: Overall, the analysis of quantitative parameters resulted in a notable upgrade in the accuracy of the diagnosis of CVT over visual inspection alone. Their high specificities make them reliable markers of CVT, yet their relatively lower sensitivities may indicate a need to perform further studies to safely eliminate the possibility of CVT in highly suspicious cases. Trial registration number: FMASU R 10/2020/2021.