Victor Arayama Cruz

Victor Arayama Cruz

Auto-generated profile, based on publicly available information

Victor Arayama Cruz

Universidade Federal de São Paulo

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in Sao Paulo Medical Journal
Verified
Journal Article
Open access
SSSibele Maria Schuantes-Paim
Sibele Maria Schuantes-Paim
RLRenata Fabiana Leite
Renata Fabiana Leite
VGVanessa Ayres Carneiro Gonçalves
Vanessa Ayres Carneiro Gonçalves
Adriana Aparecida Ferraz CarbonelAdriana Aparecida Ferraz Carbonel
Adriana Aparecida Ferraz Carbonel
ETEliana Cavalari Teraoka
Eliana Cavalari Teraoka
BRBartira de Aguiar Roza
Bartira de Aguiar Roza
BACKGROUND: Logistic and temperature challenges contribute to organ loss during transplantation. Ensuring the safety of static cold packaging for organ transport is essential to improve patient access to transplants. This study aimed to verify a method for validating the packaging used to transport organs for transplantation. DESIGN AND SETTING: Validation study and pilot test using experimental surgery on porcine organs. METHODS: Data collection considered the variables related to organ integrity before and after transportation, including temperature (measured thrice with three instruments per organ), macroscopic evaluation (based on photographic and observational assessments), histology (structural analysis of the collected samples), and packaging contamination (triple-swab sampling for microorganism growth). Data analysis was performed using descriptive statistics, visual assessment, histological processing, and microbiological evaluation. RESULTS: By the end of transportation, all the organs reached the ideal temperature range for transplantation. The similarity in swine weight and size enabled macroscopic comparisons. Histological analysis revealed no significant injuries or morphological changes. Regarding packaging, environmental microorganisms predominate, with sustainable post-transport differences. CONCLUSION: The method developed to validate the package used for transporting organs for transplantation was successfully verified. Furthermore, this method addresses the existing gap in the process of documenting a robust validation method for packaging intended for organ transportation.

11 April 2026 in Brazilian Journal of Transplantation
Verified
Journal Article
Open access
SPSibele Maria Schuantes Paim
Sibele Maria Schuantes Paim
VCVictor Arayama Cruz
Victor Arayama Cruz
KGKaroline Sabrina de Carvalho Gomes
Karoline Sabrina de Carvalho Gomes
JAJulia Karini da Silva Araujo
Julia Karini da Silva Araujo
GCGraciana Maria de Moraes Coutinho
Graciana Maria de Moraes Coutinho
BRBartira de Aguiar Roza
Bartira de Aguiar Roza
Objectives: To compare the viability of porcine pancreases transported under static cold conditions using two transport models. Methods: A prospective preclinical case-control study with an adapted design, conducted on Landrace pig organs. Data were collected from three variables: temperature, macroscopic assessment, and histology. The variables were compared using two packaging models: the experimental model, Autonomous and Intelligent Packaging for Cold Chain in Healthcare Systems (Embalagem Autônoma e Inteligente para Cadeia Fria de Sistemas de Saúde [EMAIS-SR]), and the control, a conventional thermal container widely used and filled with ice. Three thermometers were used for temperature measurements: two for internal temperature and one for surface temperature. The macroscopic evaluation analyzed color, tissue integrity, consistency, and the presence of lesions, edema, or hematomas in the organ. For histology, the samples were fixed and stained with hematoxylin-eosin, which allows visualization of tissue morphology under light microscopy, followed by immunohistochemical analysis. Results: Ten experimental surgeries were performed: six pancreases were stored under static cold conditions and transported in the active-cooling container, while four were transported in the conventional ice-filled container. Among all cases, only one pancreas had an exit temperature higher (12.1 °C) than the recommended maximum of 8 °C. However, in the macroscopic evaluation, the organ with the higher exit temperature received a better evaluation, while the others maintained a qualitative macroscopic evaluation. In histological analysis, on average, pancreases transported in the active-cooling container demonstrated better tissue quality by presenting more preserved cellular structures. Conclusion: The preclinical experimental model demonstrated that, although the organ was kept within the recommended temperature range, organs maintained in the technological solution EMAIS-SR, which does not use ice, were better preserved. Furthermore, the only case in which temperature exceeded the recommended limit, that is, in which the organ warmed after packaging, occurred in the traditional ice-filled container. The research encourages the development of new and more robust studies on clinical decisions regarding safe thermal limits and best practices for transporting pancreases intended for transplantation.

11 April 2026 in Brazilian Journal of Transplantation
Verified
Journal Article
Open access
SPSibele Maria Schuantes Paim
Sibele Maria Schuantes Paim
VCVictor Arayama Cruz
Victor Arayama Cruz
KGKaroline Sabrina de Carvalho Gomes
Karoline Sabrina de Carvalho Gomes
JAJulia Karini da Silva Araujo
Julia Karini da Silva Araujo
GCGraciana Maria de Moraes Coutinho
Graciana Maria de Moraes Coutinho
BRBartira de Aguiar Roza
Bartira de Aguiar Roza
Objetivos: Comparar a viabilidade de pâncreas suínos transportados a frio estático em dois modelos de transporte. Métodos: Estudo pré-clínico prospectivo com delineamento caso-controle adaptado, realizado em órgãos de suínos Landrace. A coleta de dados foi realizada a partir de três variáveis: temperatura, avaliação macroscópica e histologia. As variáveis foram comparadas utilizando dois modelos de acondicionamento: o caso, Embalagem Autônoma e Inteligente para Cadeia Fria de Sistemas de Saúde (EMAIS-SR), e o controle, embalagem térmica convencional amplamente utilizada e preenchida com gelo. Para temperatura, foram utilizados três termômetros: dois para temperatura interna e um para temperatura de superfície. A avaliação macroscópica analisou coloração, integridade tecidual, consistência e presença de lesões, edema ou hematomas no órgão. Para histologia, as amostras foram fixadas e coradas por hematoxilina-eosina, que possibilita a visualização da morfologia tecidual em microscopia óptica seguida de análise imuno-histoquímica. Resultados: Foram realizadas 10 cirurgias experimentais; seis pâncreas foram acondicionados a frio estático e transportados em embalagem com refrigeração ativa, enquanto quatro foram transportados em embalagem convencional com gelo. Dentre os casos, somente um pâncreas apresentou temperatura de saída mais alta (12,1 °C) que a preconizada de até 8 °C. Contudo, frente à avaliação macroscópica, o órgão com temperatura mais alta após o transporte apresentou melhor avaliação, enquanto os demais mantiveram avaliação macroscópica qualitativa. Na análise histológica, em média, os pâncreas transportados na embalagem de refrigeração ativa demonstraram melhor qualidade tecidual por apresentarem estruturas celulares mais preservadas. Conclusão: O estudo demonstrou, por meio de modelo experimental pré-clínico, que, apesar de terem sido mantidos em padrão de temperatura recomendado, os órgãos preservados na solução tecnológica EMAIS-SR, que não utiliza gelo, demonstraram-se mais bem preservados. Ademais, o único caso em que houve temperatura superior, ou seja, em que o órgão aqueceu após acondicionamento, ocorreu na embalagem tradicional com gelo. A pesquisa instiga a realização de novos e mais robustos estudos acerca de decisões clínicas sobre limites térmicos seguros e boas práticas para o transporte de pâncreas destinados ao transplante.

17 August 2026 in Packaging Technology and Science
Verified
Journal Article
Open access
SSSibele Maria Schuantes‐Paim
Sibele Maria Schuantes‐Paim
RLRenata Fabiana Leite
Renata Fabiana Leite
VCVictor Arayama Cruz
Victor Arayama Cruz
VGVanessa Ayres Carneiro Gonçalves
Vanessa Ayres Carneiro Gonçalves
JAJúlia Karini da Silva Araujo
Júlia Karini da Silva Araujo
BRBartira de Aguiar Roza
Bartira de Aguiar Roza
This study aimed to present and validate the Autonomous and Intelligent Packaging for the Cold Chain in Health Systems (EMAIS‐SR) for organ transport through an experimental model using porcine organs. To do so, Landrace porcine hearts, livers, pancreases and kidneys were transported using either EMAIS‐SR or traditional ice‐filled coolers. Following transport, organs were assessed after 2 h through collected data that included temperature monitoring, macroscopic evaluation, histological analysis and microbiological testing. Prototypes at different technology readiness levels (TRL6 and TRL7) were evaluated. Regarding the findings, EMAIS‐SR maintained organ temperatures predominantly within the recommended 2°C–8°C range. In the adjusted analysis, the TRL7 prototype achieved significantly lower post‐transport temperatures than TRL6 (adjusted difference: 2.91°C; 95% CI, 1.32–4.50; p = 0.0006), indicating improved thermal performance after system refinements. Additionally, minor macroscopic changes were observed in some samples, but without histological correlation. Histological analysis showed better tissue preservation in EMAIS‐SR samples, particularly in nuclei morphology and cytoplasmic structure. Furthermore, microbiological results indicated equivalent or lower contamination in EMAIS‐SR compared to the control, especially in later tests. Overall, EMAIS‐SR demonstrated effective thermal control, preservation of tissue integrity and biological safety in a structured preclinical model using porcine organs. Consequently, these findings validate EMAIS‐SR as a robust and clinically promising alternative to conventional organ transport systems.