Peng Diao

Peng Diao

Auto-generated profile, based on publicly available information

Peng Diao

Department of Radiation Oncology, Sichuan Cancer Hospital and Research Institute, affiliated to University of Electronic Science and Technology of China (UESTC), Chengdu, China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 November 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
JLjiahua lyu
jiahua lyu
LXLing Xiao
Ling Xiao
QWQifeng Wang
Qifeng Wang
FLFang Li
Fang Li
PDPeng Diao
Peng Diao
JLJin-yi Lang
Jin-yi Lang
The purpose of this study is to compare the efficacy and safety of concurrent chemoradiotherapy (CCRT) versus chemotherapy alone for patients with stage IV esophageal squamous cell carcinoma (ESCC). Eligible patients were retrospectively enrolled at the authors’s institution from January 2010 to October 2015. Of the 141 patients enrolled, 55 (39.0%) received CCRT and 86 (61.0%) received chemotherapy alone. The outcomes and adverse events (AEs) were compared between the two groups. The baseline clinical characteristics of the two groups were similar. However, the CCRT group showed a significantly better primary tumor objective response rate (ORR) than that of the chemotherapy group (74.5% versus 45.3%, p = 0.001). The 1-year, 2-year, 3-year overall survival (OS) rates and median OS were 58.0% versus 43.0%, 25.5% versus 14.0%, 10.7% versus 4.7%, and 14 months versus 11 months for patients treated with CCRT or chemotherapy, respectively (p = 0.007). The 1-year and median progression-free survival (PFS) were 29.8% versus 14.9% and 8 months versus 6 months (p = 0.005). Multivariate analysis identified CCRT (p = 0.013) and solitary metastasis (p = 0.037) as independent factors for greater OS. The frequency of leucocytopenia (grade 3 or higher) was significantly higher in the CCRT group than in the chemotherapy-alone group (p = 0.040), whereas the rates of other AEs did not differ. In this study, it is suggested that CCRT is more effective than chemotherapy alone for stage IV ESCC, yielding better primary responses and survival outcomes with tolerable side effects.

29 August 2022 in Frontiers in Oncology
Verified
Journal Article
Open access
BTBin Tang
Bin Tang
MLMin Liu
Min Liu
BWBingjie Wang
Bingjie Wang
PDPeng Diao
Peng Diao
JLJie Li
Jie Li
LOLucia Clara Orlandini
Lucia Clara Orlandini
Adaptive radiotherapy performed on the daily magnetic resonance imaging (MRI) is an option to improve the treatment quality. In the adapt-to-shape workflow of 1.5-T MR-Linac, the contours of structures are adjusted on the basis of patient daily MRI, and the adapted plan is recalculated on the MRI-based synthetic computed tomography (syCT) generated by bulk density assignment. Because dosimetric accuracy of this strategy is a priority and requires evaluation, this study aims to explore the usefulness of adding an assessment of dosimetric errors associated with recalculation on syCT to the clinical workflow. Sixty-one patients, with various tumor sites, treated using a 1.5-T MR-Linac were included in this study. In Monaco V5.4, the target and organs at risk (OARs) were contoured, and a reference CT plan that contains information about the outlined contours, their average electron density (ED), and the priority of ED assignment was generated. To evaluate the dosimetric error of syCT caused by the inherent approximation within bulk density assignment, the reference CT plan was recalculated on the syCT obtained from the reference CT by forcing all contoured structures to their mean ED defined on the reference plan. The dose–volume histogram (DVH) and dose distribution of the CT and syCT plan were compared. The causes of dosimetric discrepancies were investigated, and the reference plan was reworked to minimize errors if needed. For 54 patients, gamma analysis of the dose distribution on syCT and CT show a median pass rate of 99.7% and 98.5% with the criteria of 3%/3 mm and 2%/2 mm, respectively. DVH difference of targets and OARs remained less than 1.5% or 1 Gy. For the remaining patients, factors (i.e., inappropriate ED assignments) influenced the dosimetric agreement of the syCT vs. CT reference DVH by up to 21%. The causes of the errors were promptly identified, and the DVH dosimetry was realigned except for two lung treatments for which a significant discrepancy remained. The recalculation on the syCT obtained from the planning CT is a powerful tool to assess and decrease the minimal error committed during the adaptive plan on the MRI-based syCT.