Breast lymphoscintigraphy is increasingly performed before surgery to delineate the drainage to the sentinel node (SN) in the axilla. On the basis of the histologic status of harvested SNs, the disease status of the entire axilla can be predicted. This prediction allows a more limited dissection to be performed while maintaining staging accuracy comparable with that of classic axillary lymph node dissection. Lymphoscintigraphy assists surgeons in harvesting the SN during gamma probe-assisted axillary biopsy or dissection and provides a wide field of view survey, among other benefits. When certain injection protocols are used, lymphoscintigraphy can be performed in the afternoon before surgery the next morning, thus minimizing disruptions of tight surgical schedules. Image acquisition can be optimized and SN activity can be maximized by means of such factors as parameters for preparation of the radiotracer, injection techniques, energy settings for the gamma camera, breast displacement maneuvers, and techniques for marking and outlining the patient's body. The ultimate goals are to delineate the true SN, maximize activity in the node for facilitated removal (even at next-day surgery), and deliver the information to the surgeon without delaying the surgical schedule.
Sentinel node detection is an important part of the clinical management of newly diagnosed melanoma. Now there is a similar or even greater enthusiasm for sentinel node evaluation in patients with breast carcinoma. However, controversies exist regarding the dose, volume, and route of administration. Even the role of lymphoscintigraphy itself, in contrast to using only a hand-held gamma probe during surgery for sentinel node detection, is being debated. Nevertheless, many centers and surgeons find that lymphoscintigraphy images are valuable in the treatment of patients and they use lymphoscintigraphy as a guide during surgery and to confirm the results obtained with the hand-held probe. Centers just beginning to use lymphoscintigraphy may find the images especially useful. Given this fact, the authors wanted to define the practical and technical aspects of performing lymphoscintigraphy in patients with breast cancer and examined various methods for the optimization of the technique of image acquisition. The suggested technique is generally free of the controversies noted above and applies to most patients. It includes various maneuvers that aim to improve the rate of sentinel node visualization using the gamma camera and the accuracy of node detection. The recommendations presented here should prove useful for both those experienced and for those centers just beginning to use the technique of lymphoscintigraphy.
29 September 2005 in World Journal of Surgical Oncology
Background: There are no studies that have directly investigated the incremental reduction in sensory morbidity that lymphoscintigraphy images (LS) and triangulated body marking or other skin marking techniques provide during sentinel lymph node biopsy (SLNB) compared to using only the probe without LS and skin marking or using only dye. However, an indirect assessment of this potential for additional sensory morbidity reduction is possible by extracting morbidity data from studies comparing the morbidity of SLNB to that of axillary lymph node dissection.Methods: A literature search yielded 13 articles that had data on sensory morbidity at specific time points on pain, numbness or paresthesia from SLNB that used radiotracer and probe or used only dye as a primary method of finding the sentinel node (SN). Of these, 10 utilized LS, while 3 did not utilize LS. By matching the data in studies not employing LS to the studies that did, comparisons regarding the percentage of patients experiencing pain, numbness/paresthesia after SLNB could be reasonably attempted at a cutoff of 9 months.Results: In the 7 studies reporting on pain after 9 months (> 9 months) that used LS (1347 patients), 13.8% of patients reported these symptoms, while in the one study that did not use LS (143 patients), 28.7% of patients reported these symptoms at > 9 months (P < 0.0001). In the 6 studies reporting on numbness and/or paresthesia at > 9 months that used LS (601 patients), 12.5% of patients reported these symptoms, while in the 3 studies that did not use LS (229 patients), 23.1% of patients reported these symptoms at > 9 months (P = 0.0002). Similar trends were also noted for all these symptoms at ≤ 9 months.Conclusion: Because of variations in techniques and time of assessing morbidity, direct comparisons between studies are difficult. Nevertheless at a minimum, a clear trend is present: having the LS images and skin markings to assist during SLNB appears to yield more favorable morbidity outcomes for the patients compared to performing SLNB with only the probe or performing SLNB with dye alone. These results are extremely pertinent, as the main reason for performing SLNB itself in the first place is to achieve reduced morbidity.
Purpose: Preliminary results by other investigators suggest that increasing the specific activity of Tc-99m nanocolloid preparations increases the measured counts in sentinel nodes compared with lower specific-activity (SA) preparations using the same initial injected dose. The authors set out to determine whether a similar result could be perceived with Tc-99m sulfur colloid (SC) preparations. Methods: Twenty-three consecutive patients (low SA group) with successful visualization of sentinel nodes by lymphoscintigraphy before our standard protocol was changed to a higher SA preparation were compared with 28 patients (high SA group) just after the switch. Injection techniques were similar in both groups: peritumoral injections at two to four points of a mixture of half-filtered (0.22 μm filter) and unfiltered Tc-99m sulfur colloid in 6 ml followed immediately by intradermal injections of filtered sulfur colloid above the tumor. Activity levels for both types of injections ranged from 3.7 to 11.1 mBq (100 to 300 μCi). Preparation of the higher SA mixture of sulfur colloid was achieved by using only one eighth of the sulfur colloid vial contents when the same activity (125 mCi) of Tc-99 was added. Regions of interest were drawn around the images of sentinel nodes and the initial injection site in the anterior and lateral projections. Ratios of sentinel node to initial injection site count were calculated for both groups. Results: The mean ratio of sentinel node to injection site count in the high SA group was 2.9 times greater than that in the low SA group. The median ratio value was 2.7 times greater in the high SA group. Conclusion: These preliminary results suggest higher counts in the sentinel node are possible with a higher SA preparation.
The authors report on a modified lymphoscintigraphy protocol for increasing activity in the sentinel node (SN) through a specific technique (LymphoBoost). It consists of an areolar-cutaneous "junction" injection, using a very shallow, high-volume, high-specific-activity injection of 100% filtered Tc-99m sulfur colloid, as an adjunct to their standard protocol. Results from a previously optimized protocol (group 1, n = 28) were compared with those from their new protocol (group 2, n = 85), which consisted of two sets of consecutively applied (within 12 to 20 minutes) injections: group 2A composed of perilesional and intradermal injections (similar to the previous group 1) followed by group 2B LymphoBoost injections within 12 to 20 minutes in the same patients. Regions of interest were drawn around the SN and the injection sites (IS) at the end of the studies to calculate the end-of-study SN:IS ratio for both group 1 and group 2 studies. The SN:IS ratio is generally independent of dose and is a measurement of the "efficiency" of getting activity from the IS to the SN. The mean SN:IS ratio in group 2 was 3.34 times greater than that in group 1 studies (P < 0.0005). The median SN:IS ratio was 3.53 times greater in the group 2 studies. Many cases showed a dramatic increase in SN counts before the LymphoBoost injection was even completed, with more than 5% of injected activity reaching nodes at the end of the study in some patients. Multiple different lymphatic pathways were noted, but all led to the same node(s). No significant disagreement between group 2A and group 2B results was noted. Areolar-cutaneous junction injections, performed under these conditions, augment SN activity dramatically in most patients. Hotter nodes provide several benefits, especially when next-day surgery is contemplated, and should also reduce the extent of dissection needed to remove the sentinel node.
8 November 2005 in International Seminars in Surgical Oncology
Current trends in patient care include the desire for minimizing invasiveness of procedures and interventions. This aim is reflected in the increasing utilization of sentinel lymph node biopsy, which results in a lower level of morbidity in breast cancer staging, in comparison to extensive conventional axillary dissection. Optimized lymphoscintigraphy with triangulated body marking is a clinical option that can further reduce morbidity, more than when a hand held gamma probe alone is utilized. Unfortunately it is often either overlooked or not fully understood, and thus not utilized. This results in the unnecessary loss of an opportunity to further reduce morbidity. Optimized lymphoscintigraphy and triangulated body marking provides a detailed 3 dimensional map of the number and location of the sentinel nodes, available before the first incision is made. The number, location, relevance based on time/sequence of appearance of the nodes, all can influence 1) where the incision is made, 2) how extensive the dissection is, and 3) how many nodes are removed. In addition, complex patterns can arise from injections. These include prominent lymphatic channels, pseudo-sentinel nodes, echelon and reverse echelon nodes and even contamination, which are much more difficult to access with the probe only. With the detailed information provided by optimized lymphoscintigraphy and triangulated body marking, the surgeon can approach the axilla in a more enlightened fashion, in contrast to when the less informed probe only method is used. This allows for better planning, resulting in the best cosmetic effect and less trauma to the tissues, further reducing morbidity while maintaining adequate sampling of the sentinel node(s).