Thomas R. Holmes

Thomas R. Holmes

Auto-generated profile, based on publicly available information

Thomas R. Holmes

Medtronic, Minneapolis, MN USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Journal of Investigative Dermatology
Verified
Journal Article
Closed access
QSQian Song
Qian Song
XWXiao-Qi Wang
Xiao-Qi Wang
THThomas R. Holmes
Thomas R. Holmes
MBMichael Bonkowski
Michael Bonkowski
EREric W. Roth
Eric W. Roth
Amy PallerAmy Paller
Amy Paller

5 April 2023 in Cardiovascular Digital Health Journal
Verified
Journal Article
Open access
ECEdmond M. Cronin
Edmond M. Cronin
JGJoseph C. Green
Joseph C. Green
JLJeff Lande
Jeff Lande
THThomas R. Holmes
Thomas R. Holmes
DLDaniel Lexcen
Daniel Lexcen
TTTyler Taigen
Tyler Taigen
Remote monitoring of cardiac implantable electric devices improves patient outcomes and experiences. Alert-based systems notify physicians of clinical or device issues in near real-time, but their effectiveness is contingent upon device connectivity. To assess patient connectivity by analyzing alert transmission times from patient transceivers to the CareLink network. Alert transmissions were retrospectively gathered from a query of the United States de-identified Medtronic CareLink database. Alert transmission time was defined as the duration from alert occurrence to arrival at the CareLink network and was analyzed by device type, alert event, and alert type. Using data from previous studies, we computed the benefit of daily connectivity checks. The mean alert transmission time was 14.8 hours (median = 6 hours), with 90.9% of alert transmissions received within 24 hours. Implantable pulse generators (17.0 ± 40.2 hours) and cardiac resynchronization therapy-pacemakers (17.2 ± 42.5 hours) had longer alert transmission times than implantable cardioverter-defibrillators (13.7 ± 29.5 hours) and cardiac resynchronization therapy-defibrillators (13.5 ± 30.2 hours), but the median time was 6 hours for all 4 device types. There were differences in alert times between specific alert events. Based on our data and previous studies, daily connectivity checks could improve daily alert transmission success by 8.5% but would require up to nearly 800 additional hours of staff time on any given day. Alert transmission performance from Medtronic devices was satisfactory, with some delays likely underscored by patient connectivity issues. Daily connectivity checks could provide some improvement in transmission success at the expense of increased clinic burden.

2 September 2024 in Medwave
Verified
Journal Article
Closed access
APArmando Pérez-Silva
Armando Pérez-Silva
RIRodrigo Isa-Param
Rodrigo Isa-Param
JAJuan F Agudelo-Uribe
Juan F Agudelo-Uribe
APAlex Pacheco-Bouthillier
Alex Pacheco-Bouthillier
RHReece Holbrook
Reece Holbrook
NMNicolás Martinenghi
Nicolás Martinenghi
Objective Cryoballoon ablation for pulmonary vein isolation is a time-efficient procedure that can alleviate stress on electrophysiology lab resources. This analysis modeled the impact of cryoballoon ablation on electrophysiology lab operation using data from Latin America. Methods Data from centers in Argentina, Mexico, Colombia, and Chile of the were used as inputs for an electrophysiology lab efficiency simulation model. The model used the assumption that either two (today’s electrophysiology lab operations) or three (including electrophysiology lab operational changes) cryoballoon ablation procedures could be performed per day. The endpoints were the percentage of days that resulted in 1) overtime and 2) time left for an extra non-ablation electrophysiology procedure. Results Data from a total of 232 procedures from six Latin American centers were included in the analysis. The average electrophysiology lab occupancy time for all procedures in Latin America was 132 ± 62 minutes. In the Current Scenario (two procedures per day), 7.4% of simulated days resulted in overtime, and 81.4% had enough time for an extra electrophysiology procedure. In the Enhanced Productivity Scenario (three procedures per day), 16.4% of days used overtime, while 67.4% allowed time for an extra non-ablation electrophysiology procedure. Conclusions Using real-world, Latin American-specific data, we found that with operational changes, three ablation procedures could feasibly be performed daily, leaving time for an extra electrophysiology procedure on more than half of days. Thus, use of cryoballoon ablation is an effective tool to enhance electrophysiology lab efficiency in resource-constrained regions such as Latin America.