Nhu Y. Do

Nhu Y. Do

Auto-generated profile, based on publicly available information

Nhu Y. Do

Hanoi University of Mining and Geology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
NCNgo Xuan Cuong
Ngo Xuan Cuong
TNThi Hong Nguyen
Thi Hong Nguyen
NDNhu Y Do
Nhu Y Do
DNDuc Minh Nguyen
Duc Minh Nguyen
Dai-Viet N. VoDai-Viet N. Vo
Dai-Viet N. Vo
Quyet Van LeQuyet Van Le
Quyet Van Le
Recently, the demand for small grid-connected photovoltaic (PV) systems has been rapidly increasing; this is due to the reduction in the costs of grid-connected storage systems as compared to those of the stand-alone ones. Notably, the performance of the solar tracking system is not only depending on the types but also the region that they are set up and used. To understand how solar tracking systems work globally, we need to know their performance in each country and even the different parts of a country. In this study, two grid-connected PV systems with 250 W solar modules were used to investigate the efficient improvement of a single-axis sun tracking system in Central Vietnam. First, a mechanical tracking device with a linear actuator and a controller was designed and then its performance was comprehensively investigated with a grid-connected PV system. In addition to evaluating the energy gain by the tracking system, this study also considered the energy consumption of the linear actuator with its controller and a small grid-connected PV system; this has generally been omitted in previous works. Experimental results indicate that the total energy consumption of the tracking system was approximately 2–8% of the energy generated by the grid-connected PV system. The maximum overall energy generation was confirmed to have increased by up to 30.3% on a sunny day upon using the proposed tracking system; further, the net energy gain by using the sun tracker was ascertained to be 15.2% in average weather conditions. Based on the success of this work, we will keep experimenting with other parts of Vietnam. Also, we will collaborate with colleagues in other countries to create a guideline for understanding and using the solar tracker regionally and globally.

20 June 2022 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
NCNgo Xuan Cuong
Ngo Xuan Cuong
NDNhu Y Do
Nhu Y Do
QDQuoc-Vuong DANG
Quoc-Vuong DANG
This paper presents modeling and experimental studies on water spray coolers for commercial photovoltaic modules. This paper has compared the energy yield of four photovoltaic commercial modules that were installed with a fixed tilt angle being equal to the local latitude in central Vietnam, including one photovoltaic module using a water spray cooler and three photovoltaic modules without cooling. Experimental results on sunny days have been shown that the energy yield difference between four PV modules under the same working condition is lower than 1%. In addition, on sunny days when the set working temperature of the water spray cooler is 45 °C, the average improvement efficiency of a photovoltaic module using a water spray cooler compared to three reference photovoltaic modules is 2.64%, 3.83%, and 6.18%, for an average of 4.22%. A simple thermal–electrical model of a photovoltaic module with a water spray cooler has been developed and tested. The normalized root mean square error between simulated and measured results of photovoltaic module power output on a sunny day without cooling and with water spray cooler reached 6.5% and 8.5%, respectively. The obtained results are also demonstrated that the reasonableness of the simple thermal–electrical model of the photovoltaic module with water spray cooler and the feasibility of a cooling system is improved to increase the efficiency of the photovoltaic module. In addition, they can be considered as a basis for new experimental models in the future.

2 December 2024 in Engineering, Technology & Applied Science Research
Verified
Journal Article
Open access
PDF file
TATuan Le Anh
Tuan Le Anh
TBThuy Trinh Bien
Thuy Trinh Bien
NCNgo Xuan Cuong
Ngo Xuan Cuong
DTDo Anh Tuan
Do Anh Tuan
YNY. Do Nhu
Y. Do Nhu
Neodymium (NdFeB) rare earth Permanent Magnets (PMs) are widely used in the manufacturing of Line-Start Permanent Magnet Synchronous Motors (LSPMSMs). During the initial startup of LSPMSMs, irreversible PM demagnetization often occurs. This research provides a thorough examination of the PM demagnetization process during the initiation of a 15-kW, 3000-rpm LSPMSM, which was converted from a squirrel-cage Induction Motor (IM) featuring a 3-bar PM. Utilizing Ansys/Maxwell2D software for simulations and conducting experiments, this study reveals that upon starting the LSPMSM, demagnetization occurs at the two outermost PM pairs. This leads to unstable motor operation at synchronous speed, significant current fluctuations, and a substantial decrease in performance. The findings suggest that to ensure effective LSPMSM operation, it is crucial to either restrict frequent restarts or select an appropriate PM type to prevent partially irreversible demagnetization, thereby enhancing power efficiency.

26 March 2022 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
NCNgo Xuan Cuong
Ngo Xuan Cuong
NDNhu Y Do
Nhu Y Do
Recently, the use of small-scale grid-connected photovoltaic (GCPV) systems for households has been growing in Vietnam. The installation of a rooftop GCPV system provides many benefits to households, such as lowering monthly electricity bills, reducing absorbed heat of the building, and creating additional income by penetrating electric power to the grid. However, the technical issues of the payback period is complicated and requires a lot of considerations. The main goal of this study is to develop a computational model and investigate the effect of electrical energy consumption on the payback period of rooftop GCPV systems. A case study is used in this study to create a model of a rooftop GCPV system for households in north-central Vietnam under feed-in tariff (FiT) schemes. The results show that the investment rate and electrical energy consumption of the installed household have a strong influence on the payback period of the GCPV system. In the case of the lowest investment rate of 666.4 USD/kWp, the fastest payback period is 43 months for households consuming all of the generating energy of the GCPV system, and the longest payback period is 131 months for households that do not use electricity, implying that all of the generating energy of the GCPV system is connected and sold to the distribution grid. The research findings will actively assist in calculating the installed capacity suitable for households in order to have the most suitable payback period while also assisting policymakers in the future in setting a reasonable rate of feed-in tariff for rooftop GCPV systems

4 September 2023 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
TNThi Hong Nguyen
Thi Hong Nguyen
QDQuoc-Vuong DANG
Quoc-Vuong DANG
NCNgo Xuan Cuong
Ngo Xuan Cuong
NDNhu Y Do
Nhu Y Do
In pursuit of the objective of achieving "net zero emissions," many countries worldwide, including Viet Nam, have prioritized the utilization of photovoltaic technology for energy conversion. Specifically, the implementation of roof-top grid-connected photovoltaic systems (GCPV) has emerged as a highly efficient solution in urban areas. These systems offer several advantages, such as minimizing land usage, lowering monthly electricity expenses, preventing building heat, generating income for households, and reducing transmission and distribution costs. This article focuses on a comprehensive long-term analysis conducted on 51 roof-top GCPV systems in the tropical monsoon climate of Hue City, Viet Nam, during the period from 2019 to 2023. The analysis findings reveal that roof-top GCPV systems with a capacity of 3-6 kW are well-suited for households in the central region of Viet Nam, characterized by a tropical monsoon climate. These systems exhibit an average sizing ratio of 1.03. The annual average daily final yield peaked at 3.28 kWh/kWp/day in 2021 and reached its lowest point at 2.97 kWh/kWp/day in 2022. Notably, the typical slope of the yield gradually increases with the installed capacity and the studied year. Furthermore, the monthly average daily final yield demonstrates a seasonal pattern, with higher yields observed from March to August and lower yields from September to January, aligning with the climate of the study area. As the years progress, the capacity factor and performance ratio of roof-top GCPV systems display a declining trend. Throughout the entire study period, these systems successfully mitigated 664 metric tons of CO2 emissions. The evaluation of long-term yield data offers valuable insights for photovoltaic installers, operators, and system owners, aiding in system maintenance and optimizing load utilization across different time periods. Long-term performance can be used by energy managers and owners of roof-top GCPV systems to identify supply shortfalls and initiate countermeasures.

1 November 2023 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
PDF file
TTTrinh Bien Thuy
Trinh Bien Thuy
NCNgo Xuan Cuong
Ngo Xuan Cuong
LTLe Anh Tuan
Le Anh Tuan
YNY Do Nhu
Y Do Nhu
Reducing the cost of electricity to improve production efficiency is one of the urgent tasks. Nowadays, the rapid development of Neodymium rare earth (NdFeB) permanent magnet technology has promoted the creation of high-efficiency motors to replace low-efficiency induction motors to save electricity. One of them is a line-start permanent magnet synchronous motor (LSPMSM). The permanent magnet configuration significantly affects the operating characteristics of the LSPMSM, such as working current characteristics, pulsating torque, working efficiency, and starting speed. The content of the article focuses on investigating and evaluating some permanent magnet configurations affecting the working characteristics of the LSPMSM based on the finite element method through Ansys/Maxwell software. The research results are suggested for the design and manufacture of LSPMSM used in mining to save electricity.