Sheng Wang

Sheng Wang

Auto-generated profile, based on publicly available information

Sheng Wang

Beijing University of Posts and Telecommunications

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 November 2020 in Nature Communications
Verified
Journal Article
Open access
PDF file
XSXizi Sun
Xizi Sun
ZYZhisheng Yang
Zhisheng Yang
XHXiaobin Hong
Xiaobin Hong
SZSimon Zaslawski
Simon Zaslawski
SWSheng Wang
Sheng Wang
LTLuc Thévenaz
Luc Thévenaz
Distributed optical fibre sensors deliver a map of a physical quantity along an optical fibre, providing a unique solution for health monitoring of targeted structures. Considerable developments over recent years have pushed conventional distributed sensors towards their ultimate performance, while any significant improvement demands a substantial hardware overhead. Here, a technique is proposed, encoding the interrogating light signal by a single-sequence aperiodic code and spatially resolving the fibre information through a fast post-processing. The code sequence is once forever computed by a specifically developed genetic algorithm, enabling a performance enhancement using an unmodified conventional configuration for the sensor. The proposed approach is experimentally demonstrated in Brillouin and Raman based sensors, both outperforming the state-of-the-art. This methodological breakthrough can be readily implemented in existing instruments by only modifying the software, offering a simple and cost-effective upgrade towards higher performance for distributed fibre sensing.

22 June 2020 in Optics Express
Verified
Journal Article
Open access
PDF file
SWSheng Wang
Sheng Wang
ZYZhisheng Yang
Zhisheng Yang
MSMarcelo Soto
Marcelo Soto
LTLuc Thévenaz
Luc Thévenaz
The signal-to-noise ratio (SNR) of Brillouin optical time-domain analyzers (BOTDA) is modelled and experimentally validated, using direct detection with and without the use of optical pre-amplification. The behavior of SNR as a function of the Brillouin gain and the probe power reaching the photo detection is analyzed in depth using this developed model and checked using two photodetectors with different specifications. It proves that a pre-amplification associated to a good-quality photodetector and a well-matched post-processing filtering can secure the highest SNR for direct-detection BOTDA. Such an optimal SNR presents only a 2.3 dB penalty compared to the ideal shot-noise-limited case that can only be reached using rather sophisticated configurations. In addition, the model here established predicts the SNR at any fiber position in any given experimental condition.

20 July 2020 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SWSheng Wang
Sheng Wang
ZYZhisheng Yang
Zhisheng Yang
SZSimon Zaslawski
Simon Zaslawski
LTLuc Thévenaz
Luc Thévenaz
A novel, to the best of our knowledge, postprocessing technique is proposed to extract with a flexible and variable spatial resolution the information from Brillouin optical time-domain analyzers, obtained using a pulse longer than the acoustic settling time. The negative impact of the acoustic transient effect is suppressed, enabling a Brillouin response proportional to the spatial resolution and a Brillouin gain spectrum keeping its natural linewidth. This leads to a better overall sensing performance, in particular for submetric spatial resolutions, with no compromises on sensing range and measurement time.

29 June 2021 in Optics Express
Verified
Journal Article
Open access
XGXia Gao
Xia Gao
ZYZhisheng Yang
Zhisheng Yang
SWSheng Wang
Sheng Wang
XHXiaobin Hong
Xiaobin Hong
XSXizi Sun
Xizi Sun
LTLuc Thévenaz
Luc Thévenaz
Noise models for both single-pulse and coded Brillouin optical time-domain analyzers (BOTDA) are established to quantify the actual signal-to-noise ratio (SNR) enhancement provided by pulse coding at any fiber position and in any operating condition. Simulation and experimental results show that the polarization noise and spontaneous Brillouin scattering (SpBS) to signal beating noise could highly penalize the performance of coded-BOTDA, depending on the code type and the interrogated fiber position. The models also serve as a useful tool to optimize the SNR improvement by trading off the accumulated Brillouin gain and optical noises.

24 April 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
XSXizi Sun
Xizi Sun
XHXiaobin Hong
Xiaobin Hong
SWSheng Wang
Sheng Wang
XGXia Gao
Xia Gao
HGHongxiang Guo
Hongxiang Guo
Jian WuJian Wu
Jian Wu
When studying the spatial resolution and Brillouin frequency shift (BFS) uncertainty in Brillouin optical time domain analysis (BOTDA) system with a hotspot, people usually focuses on the point with best performance in the hotspot and neglect the huge error around it. The error is caused by the Brillouin gain spectrum (BGS) contributed by both the hotspot and the ambient segment, which is distorted from standard Lorentzian curve. Due to the distortion of BGS, the estimated BFS near the hotspot is shifted from the actual value and results in BFS error along the fiber. The distorted BGS can be double-peak or single-peak curve that is dependent on both the length of the hotspot that contributes to BGS and the BFS difference between the hotspot and the ambient segment. A fitting technique considering the combined contributions of hotspot and ambient segment is proposed to recover the distorted BGS near the hotspot and evaluate BFS. It is demonstrated that BFS error around hotspot is greatly reduced compare to the conventional Lorentzian fitting and dual Lorentzian fitting schemes.

28 August 2019
Verified
Conference Paper
Open access
PDF file
SZSimon Zaslawski
Simon Zaslawski
ZYZhisheng Yang
Zhisheng Yang
SWSheng Wang
Sheng Wang
LTLuc Thévenaz
Luc Thévenaz
Brillouin optical time-domain reflectometry is used to perform distributed forward stimulated Brillouin scattering (FSBS) measurements. This configuration suppresses the need for an additional frequency scanning to evaluate the local Brillouin peak gain when probing the FSBS resonance. The use of a broad pass-band filter makes the system insensitive to moderate temperature or strain fluctuations, but enables to accurately retrieve any change in intensity due to FSBS.