Didier Cassereau

Didier Cassereau

Auto-generated profile, based on publicly available information

Didier Cassereau

Laboratoire d’Imagerie Biomédicale (LIB), Sorbonne Université, CNRS, INSERM, Paris, France

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2000 in Reports on Progress in Physics
Verified
Journal Article
Closed access
PDF file
MFMathias Fink
Mathias Fink
DCDidier Cassereau
Didier Cassereau
ADArnaud Derode
Arnaud Derode
CPClaire Prada
Claire Prada
Philippe RouxPhilippe Roux
Philippe Roux
FWFrançois Wu
François Wu

1 September 1992 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
DCD. Cassereau
D. Cassereau
MFM. Fink
M. Fink
For pt.II see ibid., vol.39, no.5, p.567-78 (1992). A theoretical model for time-reversal cavities to optimize focusing in homogeneous and inhomogeneous media is described. The concept of the cavity can be understood as the most realistic approximation to an exact three-dimensional (3-D) time-reversal of ultrasonic fields; it is also a generalization of the time-reversal mirrors realized experimentally in the laboratory. The proposed method is based on an approach in the transient regime that is more general than the monochromatic formalism used in optics to analyze the phase conjugation mirrors efficiency. This method uses impulse diffraction theory to obtain the impulse response of the cavity in any inhomogeneous medium. An original interpretation of the limitations due to diffraction observed in wave field propagation in terms of the different waves generated inside the cavity is also proposed. The time-reversal focusing process using a closed cavity in a weakly inhomogeneous medium is compared with more classical techniques to compensate wavefront distortions, thus illustrating the focusing improvement due to the time-reversal method.<>

13 January 2003
Verified
Conference Paper
Closed access
MFM. Fink
M. Fink
CPC. Prada
C. Prada
FWF. Wu
F. Wu
DCD. Cassereau
D. Cassereau
Focusing on a reflective target in an inhomogenous medium is difficult. In order to obtain good focusing properties, the concept of optical phase-conjugate mirrors, valid for monochromatic signals, is extended to large-bandwidth pulses such as those used in ultrasound echography. The transducer's linear response to the acoustic pressure allows replacement of the phase conjugation by a time-reversal operation on the pulse echo signals. The time-reversal mirror is an array of transmit-receive transducers. A first incident wave is reflected by the target. The received signals are stored in shift registers, reversed in times and then reemitted. The major advantage of this process is that the waves distorted by the aberrating medium are corrected by the mirror operation and the back propagation through the medium. When the medium contains several reflectors, this time-reversal process can be iterated in order to focus on the most-reflective one.<>

8 November 2002 in Inverse Problems
Verified
Journal Article
Closed access
CPClaire Prada
Claire Prada
EKEstelle Kerbrat
Estelle Kerbrat
DCDidier Cassereau
Didier Cassereau
MFMathias Fink
Mathias Fink

31 December 2003 in The Journal of the Acoustical Society of America
Verified
Journal Article
Closed access
PDF file
LSLaurent Sandrin
Laurent Sandrin
DCDidier Cassereau
Didier Cassereau
MFMathias Fink
Mathias Fink
The transient radiation of low-frequency elastic waves through isotropic and homogeneous soft media is investigated using the Green’s function approach. A careful analysis of the coupling term is performed and yields the introduction of a very near field region in which its amplitude behaves as 1/r. To address the calculation of impulse responses, a simplified Green’s function is proposed for semi-infinite media and compared to exact solutions. Impulse response calculations are successfully compared with experimental measurements obtained for circular radiators of different diameters using transient elastography. Results presented in this paper provide a better understanding of the role of the coupling term in elastography and should be used to compensate diffraction and coupling effects observed in transient elastography.

7 November 2002 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
EKE. Kerbrat
E. Kerbrat
CPC. Prada
C. Prada
DCD. Cassereau
D. Cassereau
MFM. Fink
M. Fink
In ultrasonic nondestructive testing, the iterative time-reversal process is an adaptive technique that can be used to detect flaws in complex samples with a large array of transducers. The decomposition of the time-reversal operator (DORT) method is a detection technique that is derived from the mathematical analysis of the iterative time-reversal process. Contrary to time-reversal techniques, the DORT method does not require programmable generators, and it allows the simultaneous detection and separation of several defects. In this paper, the method is applied to a Ti6-4 titanium cylindrical sample to separate the echo of a defect from the speckle due to microstructure contribution. The grain structure of this titanium alloy makes detection very difficult and, for large depths, conventional techniques do not allow the detection of small flaws with a satisfactory signal-to-noise ratio. The efficiency of the DORT method to detect a flat bottom hole with a diameter of 0.4 mm located at a depth of 140 mm in a titanium alloy sample is shown.