Mishek Thapa

Mishek Thapa

Auto-generated profile, based on publicly available information

Mishek Thapa

David Geffen School of Medicine, University of California, Los Angeles, California

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2022 in eLife
Verified
Journal Article
Open access
MSMiranda L Scalabrino
Miranda L Scalabrino
MTMishek Thapa
Mishek Thapa
LCLindsey A Chew
Lindsey A Chew
EZEsther Zhang
Esther Zhang
JXJason Xu
Jason Xu
GFGreg D Field
Greg D Field
Rod photoreceptor degeneration causes deterioration in the morphology and physiology of cone photoreceptors along with changes in retinal circuits. These changes could diminish visual signaling at cone-mediated light levels, thereby limiting the efficacy of treatments such as gene therapy for rescuing normal, cone-mediated vision. However, the impact of progressive rod death on cone-mediated signaling remains unclear. To investigate the fidelity of retinal ganglion cell (RGC) signaling throughout disease progression, we used a mouse model of rod degeneration (Cngb1neo/neo). Despite clear deterioration of cone morphology with rod death, cone-mediated signaling among RGCs remained surprisingly robust: spatiotemporal receptive fields changed little and the mutual information between stimuli and spiking responses was relatively constant. This relative stability held until nearly all rods had died and cones had completely lost well-formed outer segments. Interestingly, RGC information rates were higher and more stable for natural movies than checkerboard noise as degeneration progressed. The main change in RGC responses with photoreceptor degeneration was a decrease in response gain. These results suggest that gene therapies for rod degenerative diseases are likely to prolong cone-mediated vision even if there are changes to cone morphology and density.

6 April 2026 in International Forum of Allergy & Rhinology
Verified
Journal Article
Open access
JBJack Birkenbeuel
Jack Birkenbeuel
MTMishek Thapa
Mishek Thapa
EEEricka L. Erickson
Ericka L. Erickson
GPGraham Pingree
Graham Pingree
KZKai Zhao
Kai Zhao
VRVinay K. Rathi
Vinay K. Rathi

8 April 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
MSMiranda L. Scalabrino
Miranda L. Scalabrino
MTMishek Thapa
Mishek Thapa
TWTian Wang
Tian Wang
ASAlapakkam P. Sampath
Alapakkam P. Sampath
JCJeannie Chen
Jeannie Chen
GFGreg D. Field
Greg D. Field
Retinitis pigmentosa is an inherited photoreceptor degeneration that begins with rod loss followed by cone loss and eventual blindness. Gene therapies are being developed, but it is unknown how retinal function depends on the time of intervention. To uncover this dependence, we utilized a mouse model of retinitis pigmentosa capable of artificial genetic rescue. This model enables a benchmark of best-case gene therapy by removing the variables that complicate the ability to answer this vital question. Complete genetic rescue was performed at 25%, 50%, and 70% rod loss (early, mid and late, respectively). Early and mid treatment restored retinal function to near wild-type levels, specifically the sensitivity and signal fidelity of retinal ganglion cells (RGCs), the ‘output’ neurons of the retina. However, some anatomical defects persisted. Late treatment retinas exhibited continued, albeit slowed, loss of sensitivity and signal fidelity among RGCs, as well as persistent gliosis. We conclude that gene replacement therapies delivered after 50% rod loss are unlikely to restore visual function to normal. This is critical information for administering gene therapies to rescue vision.

29 June 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
LDLuciano Dyballa
Luciano Dyballa
ARAndra M. Rudzite
Andra M. Rudzite
MHMahmood S. Hoseini
Mahmood S. Hoseini
MTMishek Thapa
Mishek Thapa
MSMichael P. Stryker
Michael P. Stryker
SZSteven W. Zucker
Steven W. Zucker
The retina and primary visual cortex (V1) both exhibit diverse neural populations sensitive to diverse visual features. Yet it remains unclear how neural populations in each area partition stimulus space to span these features. One possibility is that neural populations are organized into discrete groups of neurons, with each group signaling a particular constellation of features. Alternatively, neurons could be continuously distributed across feature-encoding space. To distinguish these possibilities, we presented a battery of visual stimuli to mouse retina and V1 while measuring neural responses with multi-electrode arrays. Using machine learning approaches, we developed a manifold embedding technique that captures how neural populations partition feature space and how visual responses correlate with physiological and anatomical properties of individual neurons. We show that retinal populations discretely encode features, while V1 populations provide a more continuous representation. Applying the same analysis approach to convolutional neural networks that model visual processing, we demonstrate that they partition features much more similarly to the retina, indicating they are more like big retinas than little brains.

17 February 2026 in Archives of Dermatological Research
Verified
Journal Article
Closed access
PDF file
MTMishek Thapa
Mishek Thapa
MWMagda Wojtara
Magda Wojtara
MKMichael Kasperkiewicz
Michael Kasperkiewicz

28 September 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
SRSuva Roy
Suva Roy
DWDepeng Wang
Depeng Wang
ARAndra M. Rudzite
Andra M. Rudzite
BPBenjamin Perry
Benjamin Perry
MSMiranda L. Scalabrino
Miranda L. Scalabrino
GFGreg D. Field
Greg D. Field
Visual processing in the retina depends on the collective activity of large ensembles of neurons organized in different layers. Current techniques for measuring activity of layer-specific neural ensembles rely on expensive pulsed infrared lasers to drive 2-photon activation of calcium-dependent fluorescent reporters. Here, we present a 1-photon light-sheet imaging system that can measure the activity in hundreds of ex vivo retinal neurons over a large field of view while simultaneously presenting visual stimuli. This allowed for a reliable functional classification of different retinal ganglion cell types. We also demonstrate that the system has sufficient resolution to image calcium entry at individual synaptic release sites across the axon terminals of dozens of simultaneously imaged bipolar cells. The simple design, a large field of view, and fast image acquisition, make this a powerful system for high-throughput and high-resolution measurements of retinal processing at a fraction of the cost of alternative approaches.