Andrew K. Swanson

Andrew K. Swanson

Auto-generated profile, based on publicly available information

Andrew K. Swanson

Atmospheric Chemistry and Dynamics Lab, NASA Goddard Spaceflight Center, Greenbelt, MD, USA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MCMaría Cazorla
María Cazorla
GWG. M. Wolfe
G. M. Wolfe
SBS. A. Bailey
S. A. Bailey
ASA. K. Swanson
A. K. Swanson
HAH. L. Arkinson
H. L. Arkinson
THThomas F Hanisco
Thomas F Hanisco
The NASA In Situ Airborne Formaldehyde (ISAF) instrument is a high-performance laser-based detector for gas-phase formaldehyde (HCHO). ISAF uses rotational-state specific laser excitation at 353 nm for laser-induced fluorescence (LIF) detection of HCHO. A number of features make ISAF ideal for airborne deployment, including (1) a compact, low-maintenance fiber laser, (2) a single-pass design for stable signal response, (3) a straightforward inlet design, and (4) a stand-alone data acquisition system. A full description of the instrument design is given, along with detailed performance characteristics. The accuracy of reported mixing ratios is ±10% based on calibration against IR and UV absorption of a primary HCHO standard. Precision at 1 Hz is typically better than 20% above 100 pptv, with uncertainty in the signal background contributing most to variability at low mixing ratios. The 1 Hz detection limit for a signal / noise ratio of 2 is 36 pptv for 10 mW of laser power, and the e fold time response at typical sample flow rates is 0.19 s. ISAF has already flown on several field missions and platforms with excellent results.

28 March 2018 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
GWGlenn M. Wolfe
Glenn M. Wolfe
SKS. Randy Kawa
S. Randy Kawa
THThomas F Hanisco
Thomas F Hanisco
RHReem A. Hannun
Reem A. Hannun
PNPaul A. Newman
Paul A. Newman
CSCraig A. Swenson
Craig A. Swenson
The exchange of trace gases between the Earth's surface and atmosphere strongly influences atmospheric composition. Airborne eddy covariance can quantify surface fluxes at local to regional scales (1–1000 km), potentially helping to bridge gaps between top-down and bottom-up flux estimates and offering novel insights into biophysical and biogeochemical processes. The NASA Carbon Airborne Flux Experiment (CARAFE) utilizes the NASA C-23 Sherpa aircraft with a suite of commercial and custom instrumentation to acquire fluxes of carbon dioxide, methane, sensible heat, and latent heat at high spatial resolution. Key components of the CARAFE payload are described, including the meteorological, greenhouse gas, water vapor, and surface imaging systems. Continuous wavelet transforms deliver spatially resolved fluxes along aircraft flight tracks. Flux analysis methodology is discussed in depth, with special emphasis on quantification of uncertainties. Typical uncertainties in derived surface fluxes are 40–90 % for a nominal resolution of 2 km or 16–35 % when averaged over a full leg (typically 30–40 km). CARAFE has successfully flown two missions in the eastern US in 2016 and 2017, quantifying fluxes over forest, cropland, wetlands, and water. Preliminary results from these campaigns are presented to highlight the performance of this system.

30 August 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
JCJason M. St. Clair
Jason M. St. Clair
ASAndrew K. Swanson
Andrew K. Swanson
SBSteven A. Bailey
Steven A. Bailey
THThomas F Hanisco
Thomas F Hanisco
NASA Compact Airborne Formaldehyde Experiment (CAFE) is a nonresonant laser-induced fluorescence instrument for airborne in situ measurement of formaldehyde (HCHO). The instrument is described here with highlighted improvements from the predecessor instrument, COmpact Formaldehyde FluorescencE Experiment (COFFEE). CAFE uses a 480 mW, 80 kHz laser at 355 nm to excite HCHO and detects the resulting fluorescence in the 420–550 nm range. The fluorescence is acquired at 5 ns resolution for 500 ns and the unique time profile of the HCHO fluorescence provides measurement selectivity. CAFE achieves a 1σ precision of 160 pptv (1 s) and 90 pptv (10 s) for [HCHO] = 0 pptv. The accuracy of CAFE, using its curve-fitting data processing, is estimated as ±20 % of [HCHO] + 100 pptv. CAFE has successfully flown on multiple aircraft platforms and is particularly well-suited to high-altitude research aircraft or small air quality research aircraft where high sensitivity is required but operator interaction and instrument payload is limited.

12 December 2017 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
JCJason M. St. Clair
Jason M. St. Clair
ASAndrew K. Swanson
Andrew K. Swanson
SBSteven A. Bailey
Steven A. Bailey
GWGlenn M. Wolfe
Glenn M. Wolfe
JMJosette E. Marrero
Josette E. Marrero
THThomas F Hanisco
Thomas F Hanisco
A new in situ instrument for gas-phase formaldehyde (HCHO), COmpact Formaldehyde FluorescencE Experiment (COFFEE), is presented. COFFEE utilizes non-resonant laser-induced fluorescence (NR-LIF) to measure HCHO, with 300 mW of 40 kHz 355 nm laser output exciting multiple HCHO absorption features. The resulting HCHO fluorescence is collected at 5 ns resolution, and the fluorescence time profile is fit to yield the ambient HCHO mixing ratio. Typical 1σ precision at ∼ 0 pptv HCHO is 150 pptv for 1 s data. The compact instrument was designed to operate with minimal in-flight operator interaction and infrequent maintenance (1–2 times per year). COFFEE fits in the wing pod of the Alpha Jet stationed at the NASA Ames Research Center and has successfully collected HCHO data on 27 flights through 2017 March. The frequent flights, combined with a potentially long-term data set, makes the Alpha Jet a promising platform for validation of satellite-based column HCHO.

18 December 2020 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
RHReem A. Hannun
Reem A. Hannun
ASAndrew K. Swanson
Andrew K. Swanson
SBSteven A. Bailey
Steven A. Bailey
THThomas F Hanisco
Thomas F Hanisco
TBT. Paul Bui
T. Paul Bui
TRThomas B. Ryerson
Thomas B. Ryerson
The NASA Rapid Ozone Experiment (ROZE) is a broadband cavity-enhanced UV (ultraviolet) absorption instrument for the detection of in situ ozone (O3). ROZE uses an incoherent LED (light-emitting diode) light source coupled to a high-finesse optical cavity to achieve an effective pathlength of ∼ 104 m. Due to its high sensitivity and small optical cell volume, ROZE demonstrates a 1σ precision of 80 pptv (parts per trillion by volume) in 0.1 s and 31 pptv in a 1 s integration time, as well as an e-fold time response of 50 ms. ROZE can be operated in a range of field environments, including low- and high-altitude research aircraft, and is particularly suited to O3 vertical-flux measurements using the eddy covariance technique. ROZE was successfully integrated aboard the NASA DC-8 aircraft during July–September 2019 and validated against a well-established chemiluminescence measurement of O3. A flight within the marine boundary layer also demonstrated flux measurement capabilities, and we observed a mean O3 deposition velocity of 0.029 ± 0.005 cm s−1 to the ocean surface. The performance characteristics detailed below make ROZE a robust, versatile instrument for field measurements of O3.

8 October 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SBSteven A. Bailey
Steven A. Bailey
RHReem A. Hannun
Reem A. Hannun
ASAndrew K. Swanson
Andrew K. Swanson
THThomas F Hanisco
Thomas F Hanisco
The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ∼520 m. Precision was measured as 94 pptv (1 s). To date, we have flown this instrument on three balloon test flights. This instrument records data on an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.