22 July 2003 in IEEE Engineering in Medicine and Biology Magazine
We address both technical and clinical issues of wearable biosensors (WBS). First, design concepts of a WBS are presented, with emphasis on the ring sensor developed by the author's group at MIT. The ring sensor is an ambulatory, telemetric, continuous health-monitoring device. This WBS combines miniaturized data acquisition features with advanced photoplethysmographic (PPG) techniques to acquire data related to the patient's cardiovascular state using a method that is far superior to existing fingertip PPG sensors. In particular, the ring sensor is capable of reliably monitoring a patient's heart rate, oxygen saturation, and heart rate variability. Technical issues, including motion artifact, interference with blood circulation, and battery power issues, are addressed, and effective engineering solutions to alleviate these problems are presented. Second, based on the ring sensor technology the clinical potentials of WBS monitoring are addressed.
2 January 2018 in Proceedings of the National Academy of Sciences
Significance: We have investigated how the directed cell migration toward stiffer extracellular matrix (ECM) is guided by filopodial mechanosensing of the surrounding ECM stiffness. As filopodia bind to the surrounding 3D ECM fibers, local force and displacement are created near the filopodium tip in response to the contraction of filopodia. We have looked into the time rate of changes to the force and the relative displacement between each binding site of ECM fiber (or fluorescent microbeads) and that of the filopodium tip. To quantify the local ECM stiffness sensed by the cell, we have aggregated these effects using two approaches of continuum and discrete mechanics and formulated two different equations for the effective rigidities of local ECM perceived by the cell.
7 February 2014 in Scientific Reports
Delta-like 4 (Dll4), a membrane-bound Notch ligand, plays a fundamental role in vascular development and angiogenesis. Dll4 is highly expressed in capillary endothelial tip cells and is involved in suppressing neighboring stalk cells to become tip cells during angiogenesis. Dll4-Notch signaling is mediated either by direct cell-cell contact or by Dll4-containing exosomes from a distance. However, whether Dll4-containing exosomes influence tip cells of existing capillaries is unknown. Using a 3D microfluidic device and time-lapse confocal microscopy, we show here for the first time that Dll4-containing exosomes causes tip cells to lose their filopodia and trigger capillary sprout retraction in collagen matrix. We demonstrate that Dll4 exosomes can freely travel through 3D collagen matrix and transfer Dll4 protein to distant tip cells. Upon reaching endothelial sprout, it causes filopodia and tip cell retraction. Continuous application of Dll4 exosomes from a distance lead to significant reduction of sprout formation. This effect correlates with Notch signaling activation upon Dll4-containing exosome interaction with recipient endothelial cells. Furthermore, we show that Dll4-containing exosomes increase endothelial cell motility while suppressing their proliferation. These data revealed novel functions of Dll4 in angiogenesis through exosomes.
1 August 2006 in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
A method for estimating pulse wave velocity (PWV) using circulatory waveform signals derived from multiple photoplethysmograph (PPG) sensors is described. The method employs two wearable in-line PPG sensors placed at a known distance from one another at the ulnar and digital artery. A technique for calibrating the measured pulse wave velocity to arterial blood pressure using hydrostatic pressure variation is presented. Additionally, a framework is described for estimating local arterial dynamics using PPG waveforms and multi-channel blind system ID. Initial results implementing the method on data derived from a human subject at different arterial pressures is presented. Results show that the method is capable of measuring the changes in arterial PWV that result from fluctuations in mean arterial pressure
5 October 2015 in PLOS Computational Biology
The dynamics of filopodia interacting with the surrounding extracellular matrix (ECM) play a key role in various cell-ECM interactions, but their mechanisms of interaction with the ECM in 3D environment remain poorly understood. Based on first principles, here we construct an individual-based, force-based computational model integrating four modules of 1) filopodia penetration dynamics; 2) intracellular mechanics of cellular and nuclear membranes, contractile actin stress fibers, and focal adhesion dynamics; 3) structural mechanics of ECM fiber networks; and 4) reaction-diffusion mass transfers of seven biochemical concentrations in related with chemotaxis, proteolysis, haptotaxis, and degradation in ECM to predict dynamic behaviors of filopodia that penetrate into a 3D ECM fiber network. The tip of each filopodium crawls along ECM fibers, tugs the surrounding fibers, and contracts or retracts depending on the strength of the binding and the ECM stiffness and pore size. This filopodium-ECM interaction is modeled as a stochastic process based on binding kinetics between integrins along the filopodial shaft and the ligands on the surrounding ECM fibers. This filopodia stochastic model is integrated into migratory dynamics of a whole cell in order to predict the cell invasion into 3D ECM in response to chemotaxis, haptotaxis, and durotaxis cues. Predicted average filopodia speed and that of the cell membrane advance agreed with experiments of 3D HUVEC migration at r2 > 0.95 for diverse ECMs with different pore sizes and stiffness. Cell invasion into a 3D ECM requires substantial cellular traction forces as well as the degradation of ECM. We are interested in how filopodia gain traction forces from the surrounding collagen fibers in the degradable ECM. Thereby, to create the overall computational model, we integrated four modules, each capturing a different physical aspect influencing migration: 1) filopodia penetration dynamics; 2) intracellular mechanics; 3) reaction-diffusion mass transfer; and 4) structural mechanics of ECM fiber networks. We successfully compared our model with experiments of 3D HUVEC migration for diverse ECMs with different pore sizes and stiffness. Finally, our model reveals the degradation of ECM fiber network plays an important role in filopodia penetration dynamics during both tugging and contractile phases.
17 December 2020 in IEEE/ASME Transactions on Mechatronics
Wearable robotic devices are receiving rapidly growing attentions for human-centered scenarios from medical, rehabilitation, to industrial applications. Supernumerary robotic limbs have been widely investigated for the augmentation of human limb functions, both as fingers and manipulator arms. Soft robotics offers an alternative approach to conventional motor-driven robot limbs towards safer and lighter systems, while pioneering soft supernumerary limbs are strongly limited in payload and dexterity by the soft robotic design approach, as well as the fabrication techniques. In this work, we proposed a wearable supernumerary soft robot for the human forearm, inspired by the fore flippers of otariids (eared seals). A flat flipper design was adopted, differing from the finger or arm shaped state-of-the-art works, with multiple soft actuators embedded as different joints for manipulation dexterity. The soft actuators were designed following origami (the art of paper folding) patterns, reinforced by kirigami (the art of paper cutting) fabrics. With this new approach, the proposed soft flipper incorporated 8 independent muscles, achieving over 20 times payload to self-weight ratio, while weighing less than 500g. The versatility, dexterity, and payload capability were experimentally demonstrated using a fabricated prototype with proprietary actuation and control. This work demonstrates the feasibility and unique advantages for origami + kirigami soft robots as a new approach to strong, dexterous, and yet safe and lightweight wearable robotic devices.