20 June 2022 in IEEE Transactions on Nuclear Science
The application of a CAEN DT5730 digitizer unit for fast neutron metrology is explored. Measurements were made at the Accelerator for Metrology and Neutron Applications in External Dosimetry (AMANDE) monoenergetic neutron facility of the IRSN, France, over a neutron energy range from 1.2 to 7.0 MeV using a BC501A scintillator. The DT5730 digitizer and an analog system based on NIM electronics and an MPA-3 multichannel analyzer acquisition unit were used, under identical beam conditions, for data acquisition. Several observables were compared between the two systems including the quality of pulse shape discrimination (PSD), neutron energy distribution derived from unfolding analyses, and deadtime effects over a range of beam currents from 0.1 to $5.1~\mu \text{A}$ . The suitability of the digital system for fast neutron metrology measurements both in the laboratory and in workplace fields is discussed.
31 March 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
22 January 2024 in Applied Radiation and Isotopes
The n-lab is a fast neutron facility based in the Department of Physics, University of Cape Town, offering collimated neutron beams produced by an MP 320 deuterium-tritium sealed tube neutron generator, and a 220 GBq americium-beryllium radioisotopic source. Characterisations of the spatial and energy distributions of the fast neutron beams were performed using an EJ-301 organic liquid scintillator detector and digital data acquisition system. Neutron energy spectra were obtained through unfolding analyses with MAXED, and a Monte Carlo approach to the propagation of uncertainties was implemented. Measurements of fluence and neutron emission rates were determined through the neutron activation of copper foils and subsequently used to validate the scaling of the unfolded neutron energy spectra.
11 April 2022 in EPJ Web of Conferences
We report on the development of neutron-based techniques to non-destructively measure the composition of concrete. Previous experimental studies demonstrated the viability of the unfolding technique to determine the ratio of water, sand and cement in well-characterised concrete samples from the transmitted neutron energy spectrum. In this work, we used MCNP6 simulations to demonstrate the extension of the technique to determine elemental compositions from transmitted, or scattered neutron energy spectra. In both cases, the simulated energy spectra provided a reliable method to unfold the composition of samples with known elemental ratios. The precision of the technique was limited by the statistical uncertainties of the simulated spectra, particularly for the case of scattered neutrons. The accuracy of the technique was heavily dependent on the uniqueness of each of the elemental responses, and reasonable prior knowledge of the composition. Given the promising results at this stage, future developments will include the addition of further elements to the response matrix, and experimental verification.
31 May 2025 in Applied Radiation and Isotopes
Fast neutrons are produced from cosmic ray interactions with matter posing particular dosimetric challenges for aviation and space exploration. Progress towards a compact detector system suitable for measurements of cosmic ray induced neutrons with energies up to 120 MeV is presented. The detector was comprised of a 6 mm × 6 mm × 120 mm prism of EJ-276 scintillator and a pair of MicroFC-60035 silicon photomultipliers, coupled with a digital data acquisition system. A comparison was made of pulse shape discrimination capabilities and light output resolution for single and dual silicon photomultiplier detector systems. The dual SiPM detector was characterised in mono-energetic fast neutron fields between 2.5-19.0 MeV. The simulation of detector response functions with Geant4 was explored, using measurements in mono-energetic fields to derive scaling and broadening parameters. Quasi-monoenergetic detector response functions were measured for neutrons with energies up to 16 MeV using Time-of-Flight techniques, and were used to demonstrate the spectroscopic capabilities of the prototype device through the unfolding of known neutron fields.