12 January 2022 in IEEE Transactions on Medical Robotics and Bionics
The current study highlights the development of a novel and high-accuracy Fiber Bragg Grating (FBG)-enabled tri-axial distal force sensor for minimally invasive surgical palpation. This tri-axial sensor designs the primary flexure/elastomer consisting of axial and radial force-sensitive structures in a serial configuration, based on the method of freedom and constraint topology (FACT) from the perspective of the mechanism. This method provides general guidelines for designing multi-dimensional sensor design, achieving excellent sensitivity and a large measurement range, depressing crosstalks and couplings among different axes, and keeping the sensitivity of the three directions at the same order of magnitude. Five tightly suspended optical fibers embedded with one FBG element each have been assembled with the proposed flexure. They are configured with one arranged at the axial flexure’s central line and four distributed along the circumference of the radial flexure. This tight suspension configuration generates uniform and constant strain distribution on the FBG element, thus improving resolution and repeatability and further avoiding FBG chirping. Finite element modeling (FEM)-based simulation has been conducted for performance investigation and design optimization to improve the sensor sensitivity. Static calibration experiments and in-vitro and ex-vivo palpation experiments have been performed to investigate the proposed design’s performances and feasibility. The optimized sensor prototype achieves excellent resolution values of 1.18mN and 1.81mN in the x- and y-directions within [−5N, 5N], and 2.61mN in the z-direction within [0, 5N], realizing the same order of sensitivity magnitude at each axis.
14 April 2021 in IEEE Transactions on Medical Robotics and Bionics
This paper presents the development of a novel and high-precision Fiber Bragg Grating (FBG)-based sensor for the measurement of insertion forces during the needle puncture procedure. The proposed sensor mainly comprises two compact orthogonal planar springs connected in a parallel arrangement, one suspended FBG optical fiber and a hand-held sensor frame. Two orthogonal planar springs with curved limbs have been utilized to design the force-sensitive flexure with an excellent linear force-displacement relationship along the axial direction. The employed optical fiber has been arranged along the flexure’s central line, and it is tightly suspended under a pre-tension force with its two ends glued. This two-point pasting configuration can attain improved sensitivity and resolution and avoid the drawbacks of chirping and low repeatability. Finite element modeling (FEM)-enabled simulation has been implemented for design optimization to further advance the sensor sensitivity and performance investigation. The sensor’s axial sensitivity has been increased in the condition when the radial crosstalk decreased. The proposed sensor has been prototyped and calibrated to achieve a high resolution of 1.5mN within [0, 6N] and an excellent linearity with a small linearity error of 0.5%. This design can be conveniently customized to achieve adjustable measurement range and force sensitivity, which has been validated by the further simulation sensor version with a resolution of 4.9mN within [0, 20N]. In-vitro puncture experiments on silicone phantoms, artificial venipuncture simulation module and eggshell membrane, and ex-vivo puncture experiments on porcine liver and porcine aorta have been implemented to validate the effectiveness of the presented sensor design.
15 July 2021 in IEEE Sensors Journal
This paper proposes a novel Fiber Bragg Grating (FBG)-based hybrid force and displacement sensor with a high sensitivity to achieve accurate measurement of radial artery pulse waveforms. The proposed sensor prototype mainly consists of a force-sensitive orthogonal planar spring structure, an FBG optical fiber, and a sensor frame. The side-type orthogonal planar spring flexure has been utilized and optimized to achieve an excellent linear force-displacement relationship along the axial direction. It offers other merits in terms of equivalent functions as a parallel mechanism configuration, compactness, and convenient assembly. The employed optical fiber has been tightly stretched to form a suspended configuration vertical to the flexure’s central line. This two-point pasting configuration and the use of the transverse movement property of the suspended fiber can achieve improved sensitivity and resolution, and avoid shortcomings associated with the traditional and direct pasting for the whole FBG element. The theoretical model that corresponds to the sensing principle has been derived. The simulation based on finite element method (FEM) has been adopted to conduct design optimization to determine detailed structural parameters and achieve enhanced sensitivity, as well as performance investigation. The optimized prototype has demonstrated an excellent force resolution of 0.47mN with a small linearity error of 0.98% within the sensing range [0.9N, 2.7N] and a high displacement sensitivity of $0.103\mu \text{m}$ with a linearity error of 4.08% within the sensing range [0.3mm, 0.7mm], and the R 2 values are determined as 99.99% and 99.30%, respectively. The experiments for artery pulse waveform measurement have been performed to validate the effectiveness of the proposed sensor design.
9 July 2021 in IEEE Sensors Journal
This paper presents a Fiber Bragg Grating (FBG)-based torque sensor with high sensitivity and miniature size for MIS instruments and multi-finger hands. The proposed sensor design mainly consists of a torque-sensitive flexure structure and two diagonally arranged optical fibers embedded with FBG sensing elements. An improved hollow hexaform structure with flexible hinges has been utilized to design the torque-sensitive flexure with an excellent linear measurement range and a solid capacity to resist non-torsion loading. Two optical fibers with an FBG inscribed each adopt a two-point gluing configuration with a tightly stretched status, and they are arranged diagonally along the hyperboloid surface. This configuration can obtain improved sensitivity and resolution and avoid the drawbacks of FBG chirping and low repeatability. Finite element modeling (FEM)-enabled simulation has been implemented to perform design optimization for further sensor sensitivity improvement and performance investigation. The prototyped sensor has been calibrated and achieves a high resolution of 0.062N ·mm within [-100, 100N ·mm] and excellent linearity with a small linearity error of 0.68%. The crosstalk experiments on the bending moment of Mx and My and the axial force have been conducted to validate the anti-interference capacity on the basis of the small values of 0.47%, 0.31%, and 1.78%. The proposed design also supports convenient customization to achieve the adjustable measuring range and torque sensitivity, which has been validated by another sensor version with a resolution of 0.26 N·mm within [-500, 500N ·mm].
12 November 2021 in IEEE Sensors Journal
This work proposes a miniature and high-sensitivity torque sensor that mainly consists of a torque-sensitive flexure and one tightly suspended optic fiber with an inscribed Fiber Bragg Grating (FBG) element for application in minimally invasive surgery robots and multi-finger robotic hands. The proposed flexure can achieve a torsion-translation conversion with a linear measurement range and a solid resistance to moment loadings. It is implemented based on the hybrid design among the specially designed hyperboloid, hollow cruciform, and cross-beam structures. The mounted FBG fiber has been configured at the flexure’s central line with its two ends glued. This tight suspension configuration can improve resolution and sensitivity and avoid FBG chirping compared to the direct FBG-pasting methods. The flexure translational motion overlaps with the FBG fiber suspension direction, generating a large and uniform strain distribution on the suspended FBG. Design optimization has been performed based on finite element modeling (FEM) simulation for structural investigation and sensor sensitivity enhancement. The prototyped sensor achieved a high resolution of $0.295 {\mathrm {~N}} \cdot {\mathrm {mm}}$ within [−600, $600 {\mathrm {~N}} \cdot {\mathrm {mm}}$ ] and exhibited excellent linearity with a small linearity error of 1.24%. The dynamic experiments demonstrated small crosstalk values of 1.6% and 3.4% for Mx and My moments. Furthermore, the proposed design supports convenient customization, and it can also achieve a resolution of $0.81 {\mathrm {~N}} \cdot {\mathrm {mm}}$ within [−2000, $2000 {\mathrm {~N}} \cdot {\mathrm {mm}}$ ] by structural modification.