Dong Han

Dong Han

Auto-generated profile, based on publicly available information

Dong Han

Department of Surgery, University of Maryland School of Medicine, Baltimore, Maryland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2022 in Medicine in Novel Technology and Devices
Verified
Journal Article
Open access
DHDong Han
Dong Han
JLJoshua L. Leibowitz
Joshua L. Leibowitz
LHLu Han
Lu Han
SWShigang Wang
Shigang Wang
GHGe He
Ge He
Zhongjun Jon WuZhongjun Jon Wu
Zhongjun Jon Wu
Centrifugal blood pumps have become popular for adult extracorporeal membrane oxygenation (ECMO) due to their superior blood handling and reduced thrombosis risk featured by their secondary flow paths that avoid stagnant areas. However, the high rotational speed within a centrifugal blood pump can introduce high shear stress, causing a significant shear-induced hemolysis rate. The Revolution pump, the Rotaflow pump, and the CentriMag pump are three of the leading centrifugal blood pumps on the market. Although many experimental and computational studies have focused on evaluating the hydraulic and hemolytic performances of the Rotaflow and CentriMag pumps, there are few on the Revolution pump. Furthermore, a thorough direct comparison of these three pumps' flow characteristics and hemolysis is not available. In this study, we conducted a computational and experimental analysis to compare the hemolytic performances of the Revolution, Rotaflow, and CentriMag pumps operating under a clinically relevant condition, i.e., the blood flow rate of 5 L/min and pump pressure head of 350 mmHg, for adult ECMO support. In silico simulations were used to characterize the shear stress distributions and predict the hemolysis index, while in vitro blood loop studies experimentally determined hemolysis performance. Comparative simulation results and experimental data demonstrated that the CentriMag pump caused the lowest hemolysis while the Revolution pump generated the highest hemolysis.

1 September 2008 in Journal of Mechanical Science and Technology
Verified
Journal Article
Closed access
PDF file
YPYoungho Park
Youngho Park
DHDong Chul Han
Dong Chul Han
IPIn Hwang Park
In Hwang Park
HAHyeong Joon Ahn
Hyeong Joon Ahn
DJDong Young Jang
Dong Young Jang

1 March 2020 in Journal of Computational Physics
Verified
Journal Article
Closed access
DHDong Han
Dong Han
GLG.R. Liu
G.R. Liu
SAShaaban Abdallah
Shaaban Abdallah

19 May 2024 in ASAIO Journal
Verified
Journal Article
Closed access
JZJiafeng Zhang
Jiafeng Zhang
DHDong Han
Dong Han
ZCZengsheng Chen
Zengsheng Chen
SWShigang Wang
Shigang Wang
WSWenji Sun
Wenji Sun
Zhongjun Jon WuZhongjun Jon Wu
Zhongjun Jon Wu
Thrombotic and bleeding events are the most common hematologic complications in patients with mechanically assisted circulation and are closely related to device-induced platelet dysfunction. In this study, we sought to link computational fluid dynamics (CFD) modeling of blood pumps with device-induced platelet defects. Fresh human blood was circulated in circulatory loops with four pumps (CentriMag, HVAD, HeartMate II, and CH-VAD) operated under a total of six clinically representative conditions. Blood samples were collected and analyzed for glycoprotein (GP) IIb/IIIa activation and receptor shedding of GPIbα and GPVI. In parallel, CFD modeling was performed to characterize the blood flow in these pumps. Numerical indices of platelet defects were derived from CFD modeling incorporating previously derived power-law models under constant shear conditions. Numerical results were correlated with experimental results by regression analysis. The results suggested that a scalar shear stress of less than 75 Pa may have limited contribution to platelet damage. The platelet defect indices predicted by the CFD power-law models after excluding shear stress <75 Pa correlated excellently with experimentally measured indices. Although numerical prediction based on the power-law model cannot directly reproduce the experimental data. The power-law model has proven its effectiveness, especially for quantitative comparisons.

1 January 2019 in Computers & Fluids
Verified
Journal Article
Closed access
DHDong Han
Dong Han
GLGr. Liu
Gr. Liu
SAShaaban Abdallah
Shaaban Abdallah

19 February 2025 in ASAIO Journal
Verified
Journal Article
Closed access
DHDong Han
Dong Han
JZJiafeng Zhang
Jiafeng Zhang
ASAakash Shah
Aakash Shah
BGBartley P. Griffith
Bartley P. Griffith
Zhongjun Jon WuZhongjun Jon Wu
Zhongjun Jon Wu
Although extracorporeal membrane oxygenation (ECMO) systems have been used to provide temporary support for patients with severe respiratory or cardiac failure, they are often bedridden, in part because of their bulky size which relies solely on an unlimited source of wall oxygen. However, there is an unmet clinical need for ambulatory ECMO which necessitates downsizing the ECMO system. We sought to develop a new oxygenator to reduce the dependence on the oxygen supply source. The proposed oxygenator features a dual-chamber gas exchangers, with one chamber primarily responsible for carbon dioxide removal using ambient air and a subsequent chamber primarily responsible for oxygen transfer using pure oxygen. Computational fluid dynamics was used to analyze the blood flow field to avoid adverse stagnation and optimize gas exchange performance. Bovine blood was used for in vitro gas transfer test. This new oxygenator demonstrated the capability to provide adequate respiratory support (both carbon dioxide removal and oxygen transfer) to adult patients at blood rate of 4–6 L/min with an oxygen supply of only 2 L/min. The reduced use of oxygen with this new oxygenator may pave the way for the development of potable ECMO systems.