Muhammad Ahmad Farooq

Muhammad Ahmad Farooq

Auto-generated profile, based on publicly available information

Muhammad Ahmad Farooq

Department of Civil Engineering, Faculty of Engineering and Technology, Institute of Southern Punjab, Multan, Pakistan

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2022 in Mechanics of Advanced Materials and Structures
Verified
Journal Article
Closed access
JBJamel Baili
Jamel Baili
Ali RazaAli Raza
Ali Raza
MAMarc Azab
Marc Azab
KAKhawar Ali
Khawar Ali
MOMohamed Hechmi El Ouni El Ouni
Mohamed Hechmi El Ouni El Ouni
MFMuhammad Ahmad Farooq
Muhammad Ahmad Farooq
This research studies the structural performance of glass fiber-reinforced polymer (glass-FRP) reinforced concrete (RC) columns incorporating glass hybrid fibers (GFC) and steel rebars RC columns having steel hybrid fibers (SFC) using experiments, artificial neural networks (NN), and theoretical modeling. A set of 18 circular concrete columns, each with a diameter of 300 mm and a height of 1200 mm, was constructed and axially loaded to failure. Glass fibers and steel fibers were incorporated to produce hybrid fiber-RC (HFRC). Nine samples were manufactured with glass-FRP reinforcement, while the remaining nine were manufactured with steel reinforcement. According to the findings, the GFC columns had lower axial strengths (ASs) up to 20%, and higher ductility indices up to 26% than the SFC columns. Both GFC and SFC columns showed the same influence of eccentric loading in the form of a decrease in AS. To develop a novel NN model, a database of 275 specimens of glass-FRP-RC columns was gathered from previous studies. To achieve an optimum model, the NN model was calibrated for different numbers of neurons in the hidden layers (HLs). A novel theoretical equation for determining the AS of GFC columns was also suggested. The proposed theoretical and NN models showed average discrepancies of 3.2 and 1.9% from the test results of both GFC and SFC columns.

5 August 2022 in European Journal of Environmental and Civil Engineering
Verified
Journal Article
Closed access
BABabar Ali
Babar Ali
MFMuhammad Ahmad Farooq
Muhammad Ahmad Farooq
Rawaz KurdaRawaz Kurda
Rawaz Kurda
RARayed Alyousef
Rayed Alyousef
Muhammad NomanMuhammad Noman
Muhammad Noman
HAHisham Alabduljabbar
Hisham Alabduljabbar
Tire-bead steel wires derived from the pyrolysis of waste-tires can be converted into the discrete reinforcement for fiber-reinforced concrete (FRC). This study for the first time presents the information about selecting the optimum dosage of recycled steel-fibers (RSF) in FRC application. Therefore, two most common types of RSF i.e., plain RSF (PRSF) and twisted RSF (TRSF) were incorporated in a high strength plain concrete (PC) at seven different volume fractions i.e., 0%, 0.25%, 0.5%, 0.75%, 1%, 1.5% and 2%. Both physical and mechanical properties of FRCs were studied including density, compressive strength-fCU, modulus of rupture-fR, splitting-tensile strength-fSP, ultra-sonic pulse velocity-UPV, and water absorption-WA. The results revealed that TRSF performed better than PRSF in overall mechanical performance. Maximum compressive strength-fCU, 9-12% higher than PC, was achieved with a 0.75% volume fraction of PRSF or TRSF. TRSF was extremely useful in upgrading the fSP and fR by more than 82% and 109%, respectively, at a 1.5% volume fraction w.r.t PC. PRSF-FRC showed lower permeability than TRSF-FRC at the same volume fraction. Lower volume fractions i.e., 0.25-0.5% RSF reduced the permeability of FRC, while higher volume fractions were detrimental to WA and RCP resistance. Experimental values of mechanical (i.e., fSP and fR) and permeability properties (i.e., WA and RCP) were accurately related to predicting RSF-FRC as a function of strength class of PC and reinforcement index. Graphical Abstract