Pablo Martínez-Cañada

Pablo Martínez-Cañada

Auto-generated profile, based on publicly available information

Pablo Martínez-Cañada

Research Center for Information and Communication Technologies (CITIC), University of Granada, Granada, Spain

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2020 in eLife
Verified
Journal Article
Open access
STStavros Trakoshis
Stavros Trakoshis
PMPablo Martínez-Cañada
Pablo Martínez-Cañada
FRFederico Rocchi
Federico Rocchi
CCCarola Canella
Carola Canella
WYWonsang You
Wonsang You
MLMichael V Lombardo
Michael V Lombardo
Excitation-inhibition (E:I) imbalance is theorized as an important pathophysiological mechanism in autism. Autism affects males more frequently than females and sex-related mechanisms (e.g., X-linked genes, androgen hormones) can influence E:I balance. This suggests that E:I imbalance may affect autism differently in males versus females. With a combination of in-silico modeling and in-vivo chemogenetic manipulations in mice, we first show that a time-series metric estimated from fMRI BOLD signal, the Hurst exponent (H), can be an index for underlying change in the synaptic E:I ratio. In autism we find that H is reduced, indicating increased excitation, in the medial prefrontal cortex (MPFC) of autistic males but not females. Increasingly intact MPFC H is also associated with heightened ability to behaviorally camouflage social-communicative difficulties, but only in autistic females. This work suggests that H in BOLD can index synaptic E:I ratio and that E:I imbalance affects autistic males and females differently.

25 January 2017 in Frontiers in Neurorobotics
Verified
Journal Article
Open access
EFEgidio Falotico
Egidio Falotico
LVLorenzo Vannucci
Lorenzo Vannucci
AAAlessandro Ambrosano
Alessandro Ambrosano
UAUgo Albanese
Ugo Albanese
SUStefan Ulbrich
Stefan Ulbrich
MGMarc-Oliver Gewaltig
Marc-Oliver Gewaltig
Combined efforts in the fields of neuroscience, computer science and biology allowed to design biologically realistic models of the brain based on spiking neural networks. For a proper validation of these models, an embodiment in a dynamic and rich sensory environment, where the model is exposed to a realistic sensory-motor task, is needed. Due to the complexity of these brain models that, at the current stage, cannot deal with real-time constraints, it is not possible to embed them into a real world task. Rather, the embodiment has to be simulated as well. While adequate tools exist to simulate either complex neural networks or robots and their environments, there is so far no tool that allows to easily establish a communication between brain and body models. The Neurorobotics Platform is a new web-based environment that aims to filling this gap by offering scientists and technology developers a software infrastructure allowing them to connect brain models to detailed simulations of robot bodies and environments and to use the resulting neurorobotic systems for in-silico experimentation. In order to simplify the workflow and reduce the level of the required programming skills, the platform provides editors for the specification of experimental sequences and conditions, envi-ronments, robots, and brain-body connectors. In addition to that, a variety of existing robots and environments are provided. This work presents the architecture of the first release of the Neurorobotics Platform developed in subproject 10 “Neurorobotics” of the Human Brain Project (HBP). At the current state, the Neurorobotics Platform allows researchers to design and run basic experiments in neurorobotics using simulated robots and simulated environments linked to simplified versions of brain models. We illustrate the capabilities of the platform with three example experiments: a Braitenberg task implemented on a mobile robot, a sensory-motor learning task based on a robotic controller and a visual tracking embedding a retina model on the iCub humanoid robot. These use-cases allow to assess the applicability of the Neurorobotics Platform for robotic tasks as well as in neuroscientific experiments.

1 July 2023 in Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring
Verified
Journal Article
Open access
PMPablo Martínez‐Cañada
Pablo Martínez‐Cañada
EPEduardo Perez‐Valero
Eduardo Perez‐Valero
JMJesus Minguillon
Jesus Minguillon
FPFrancisco Pelayo
Francisco Pelayo
MLMiguel A. López‐Gordo
Miguel A. López‐Gordo
CMChristian Morillas
Christian Morillas
INTRODUCTION: Accumulation and interaction of amyloid‐beta (Aβ) and tau proteins during progression of Alzheimer's disease (AD) are shown to tilt neuronal circuits away from balanced excitation/inhibition (E/I). Current available techniques for noninvasive interrogation of E/I in the intact human brain, for example, magnetic resonance spectroscopy (MRS), are highly restrictive (i.e., limited spatial extent), have low temporal and spatial resolution and suffer from the limited ability to distinguish accurately between different neurotransmitters complicating its interpretation. As such, these methods alone offer an incomplete explanation of E/I. Recently, the aperiodic component of neural power spectrum, often referred to in the literature as the ‘1/f slope’, has been described as a promising and scalable biomarker that can track disruptions in E/I potentially underlying a spectrum of clinical conditions, such as autism, schizophrenia, or epilepsy, as well as developmental E/I changes as seen in aging.METHODS: Using 1/f slopes from resting‐state spectral data and computational modeling, we developed a new method for inferring E/I alterations in AD.RESULTS: We tested our method on recent freely and publicly available electroencephalography (EEG) and magnetoencephalography (MEG) datasets of patients with AD or prodromal disease and demonstrated the method's potential for uncovering regional patterns of abnormal excitatory and inhibitory parameters.DISCUSSION: Our results provide a general framework for investigating circuit‐level disorders in AD and developing therapeutic interventions that aim to restore the balance between excitation and inhibition.

2 April 2021 in PLOS Computational Biology
Verified
Journal Article
Open access
PDF file
PMPablo Martínez-Cañada
Pablo Martínez-Cañada
TNTorbjørn V. Ness
Torbjørn V. Ness
GEGaute T. Einevoll
Gaute T. Einevoll
TFTommaso Fellin
Tommaso Fellin
Stefano PanzeriStefano Panzeri
Stefano Panzeri
The electroencephalogram (EEG) is a major tool for non-invasively studying brain function and dysfunction. Comparing experimentally recorded EEGs with neural network models is important to better interpret EEGs in terms of neural mechanisms. Most current neural network models use networks of simple point neurons. They capture important properties of cortical dynamics, and are numerically or analytically tractable. However, point neurons cannot generate an EEG, as EEG generation requires spatially separated transmembrane currents. Here, we explored how to compute an accurate approximation of a rodent’s EEG with quantities defined in point-neuron network models. We constructed different approximations (or proxies) of the EEG signal that can be computed from networks of leaky integrate-and-fire (LIF) point neurons, such as firing rates, membrane potentials, and combinations of synaptic currents. We then evaluated how well each proxy reconstructed a ground-truth EEG obtained when the synaptic currents of the LIF model network were fed into a three-dimensional network model of multicompartmental neurons with realistic morphologies. Proxies based on linear combinations of AMPA and GABA currents performed better than proxies based on firing rates or membrane potentials. A new class of proxies, based on an optimized linear combination of time-shifted AMPA and GABA currents, provided the most accurate estimate of the EEG over a wide range of network states. The new linear proxies explained 85–95% of the variance of the ground-truth EEG for a wide range of network configurations including different cell morphologies, distributions of presynaptic inputs, positions of the recording electrode, and spatial extensions of the network. Non-linear EEG proxies using a convolutional neural network (CNN) on synaptic currents increased proxy performance by a further 2–8%. Our proxies can be used to easily calculate a biologically realistic EEG signal directly from point-neuron simulations thus facilitating a quantitative comparison between computational models and experimental EEG recordings.

24 August 2016 in International Journal of Neural Systems
Verified
Journal Article
Closed access
PMPablo Martínez-Cañada
Pablo Martínez-Cañada
CMChristian Morillas
Christian Morillas
BPBegoña Pino
Begoña Pino
EREduardo Ros
Eduardo Ros
FPFrancisco Pelayo
Francisco Pelayo

15 February 2012 in EURASIP Journal on Image and Video Processing
Verified
Journal Article
Open access
PDF file
RURaquel Ureña
Raquel Ureña
PMPablo Martínez-Cañada
Pablo Martínez-Cañada
JGJuán Manuel Gómez-López
Juán Manuel Gómez-López
CMChristian Morillas
Christian Morillas
FPFrancisco Pelayo
Francisco Pelayo
Low-level computer vision algorithms have high computational requirements. In this study, we present two real-time architectures using resource constrained FPGA and GPU devices for the computation of a new algorithm which performs tone mapping, contrast enhancement, and glare mitigation. Our goal is to implement this operator in a portable and battery-operated device, in order to obtain a low vision aid specially aimed at visually impaired people who struggle to manage themselves in environments where illumination is not uniform or changes rapidly. This aid device processes in real-time, with minimum latency, the input of a camera and shows the enhanced image on a head mounted display (HMD). Therefore, the proposed operator has been implemented on battery-operated platforms, one based on the GPU NVIDIA ION2 and another on the FPGA Spartan III, which perform at rates of 30 and 60 frames per second, respectively, when working with VGA resolution images (640 × 480).