Diagnosis and treatment of small saphenous vein (SSV) insufficiency is of utmost importance for relieving chronic venous insufficiency symptoms. To investigate the efficacy and safety of five different treatment approaches among patients with SSV insufficiency. Two-center retrospective clinical study, conducted at cardiovascular surgery clinics in a local training and research hospital and a state hospital. A total of 282 extremities of 268 patients with SSV insufficiency alone who were treated for symptomatic varicose veins between January 2012 and January 2017 were included in the study. All extremities included in the study were divided into five groups as follows: high ligation + stripping; radiofrequency ablation (RFA); cyanoacrylate closure (CAC); and endovenous laser ablation (EVLA) at the wavelengths 980 nm and 1,470 nm. Although the recurrence rate at six months was similar among the treatment groups, we found significant differences in recurrence rates at one year, with lower rates in the CAC, RFA and 1,470 nm EVLA groups, compared with the other treatments (P = 0.005). No sural neuritis was observed in the CAC group. The pigmentation rate was higher in the two EVLA groups (980 nm and 1,470 nm). Our study results showed that although CAC, RFA and EVLA at 1,470 nm seemed to be effective methods for treating SSV insufficiency alone, CAC and RFA had better aesthetic results than EVLA at 1,470 nm. We consider that endovenous non-thermal techniques for treating SSV insufficiency may be preferable because of relatively low risk of nerve injury.
Objectives: The performance of small-diameter (3–5-mm) vascular grafts still poses a challenge in the field of vascular surgery. We present here our preliminary experience with implanting unique small-sized polycarbonate urethane vascular grafts in 7 dogs. Material and Methods: Each animal was implanted with 4 interposition grafts, 2 femoral and 2 carotid. No anti-thrombotic medication was administered. Doppler sonography was performed at 3-month intervals to examine for patency and flow characteristics. Animals were sacrificed electively at 3, 6 and 12 months. Results: At 3 months, all grafts were patent. After 6 months, 3 grafts occluded and at 1 year a further 6 grafts occluded. Hence 9 of 28 grafts occluded (67.9% patency). During the study, no correlation could be established between flow velocity or resistance index and occlusion. Histopathology showed intimal hyperplasia to be the cause of occlusion. Conclusions: Compared to literature data on small-diameter grafts in the same position, ADIAM’s Biomechanical grafts performed clearly better. Compliance data suggest a correlation between elastic compliance and patency.