High-contrast, high-resolution imaging of biomedical specimens is indispensable for studying organ function and pathologies. Conventional histology, the gold standard for soft-tissue visualization, is limited by its anisotropic spatial resolution, elaborate sample preparation, and lack of quantitative image information. X-ray absorption or phase tomography have been identified as promising alternatives enabling non-destructive, distortion-free three-dimensional (3D) imaging. However, reaching sufficient contrast and resolution with a simple experimental procedure remains a major challenge. Here, we present a solution based on x-ray phase tomography through speckle-based imaging (SBI). We demonstrate on a mouse kidney that SBI delivers comprehensive 3D maps of hydrated, unstained soft tissue, revealing its microstructure and delivering quantitative tissue-density values at a density resolution of better than and spatial resolution of better than 8 µm. We expect that SBI virtual histology will find widespread application in biomedicine and will open up new possibilities for research and histopathology.
Micrometer-resolution neuroimaging with gold-standard conventional histology requires tissue fixation and embedding. The exchange of solvents for the creation of sectionable paraffin blocks modifies tissue density and generates non-uniform brain shrinkage. We employed synchrotron radiation-based X-ray microtomography for slicing- and label-free virtual histology of the mouse brain at different stages of the standard preparation protocol from formalin fixation via ascending ethanol solutions and xylene to paraffin embedding. Segmentation of anatomical regions allowed us to quantify non-uniform tissue shrinkage. Global and local changes in X-ray absorption gave insight into contrast enhancement for virtual histology. The volume of the entire mouse brain was 60%, 56%, and 40% of that in formalin for, respectively, 100% ethanol, xylene, and paraffin. The volume changes of anatomical regions such as the hippocampus, anterior commissure, and ventricles differ from the global volume change. X-ray absorption of the full brain decreased, while local absorption differences increased, resulting in enhanced contrast for virtual histology. These trends were also observed with laboratory microtomography measurements. Microtomography provided sub-10 μm spatial resolution with sufficient density resolution to resolve anatomical structures at each step of the embedding protocol. The spatial resolution of conventional computed tomography and magnetic resonance microscopy is an order of magnitude lower and both do not match the contrast of microtomography over the entire embedding protocol. Unlike feature-to-feature or total volume measurements, our approach allows for calculation of volume change based on segmentation. We present isotropic micrometer-resolution imaging to quantify morphology and composition changes in a mouse brain during the standard histological preparation. The proposed method can be employed to identify the most appropriate embedding medium for anatomical feature visualization, to reveal the basis for the dramatic X-ray contrast enhancement observed in numerous embedded tissues, and to quantify morphological changes during tissue fixation and embedding.
Hard x-ray tomography with Paganin's widespread single-distance phase retrieval filter improves the contrast-to-noise ratio (CNR) while reducing spatial resolution (SR). We demonstrate that a Gaussian filter provided larger CNR at high SR with interpretable density measurements for two medically relevant soft tissue samples. Paganin's filter produced larger CNR at low SR, though a priori assumptions were generally false and image quality gains diminish for CNR > 1. Therefore, simple absorption measurements of low-Z specimens combined with Gaussian filtering can provide improved image quality and model-independent density measurements compared to single-distance phase retrieval.
Scientists are increasingly required by funding agencies, publishers and their institutions to produce and publish data that are Findable, Accessible, Interoperable and Reusable (FAIR). This requires curatorial activities, which are expensive in terms of both time and effort. Based on our experience of supporting a multidisciplinary research team, we provide recommendations to direct the efforts of researchers towards affordable ways to achieve a reasonable degree of “FAIRness” for their data to become reusable upon its publication. The recommendations are accompanied by concrete insights on the challenges faced when trying to implement them in an actual data-intensive reference project.