Sung Phil Yang

Sung Phil Yang

Auto-generated profile, based on publicly available information

Sung Phil Yang

Department of Gait Lab National Rehabilitation Center Seoul South Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 April 2020 in Annals of Rehabilitation Medicine
Verified
Journal Article
Open access
PDF file
SKSeung Hyun Kwon
Seung Hyun Kwon
BLBum Suk Lee
Bum Suk Lee
HLHye Jin Lee
Hye Jin Lee
EKEun Joo Kim
Eun Joo Kim
JLJungah Lee
Jungah Lee
SOSang Wook Oh
Sang Wook Oh
Objective To compare the energy efficiency of gait with knee-ankle-foot orthosis (KAFO) and robot-assisted gait and to develop a usability questionnaire to evaluate the satisfaction of walking devices in paraplegic patients with spinal cord injuries.Methods Thirteen patients with complete paraplegia participated and 10 completed the evaluation. They were trained to walk with KAFO (KAFO-gait) or a ReWalk robot (ReWalk-gait) for 4 weeks (20 sessions). After a 2-week wash-out period, they switched walking devices and underwent 4 additional weeks of training. Two evaluations were performed (after 2 and 4 weeks) following the training periods for each walking device, using the 6-minute walking test (6MWT) and 30-minute walking test (30MWT). The spatiotemporal variables (walking distance, velocity, and cadence) and energy expenditure (heart rate, maximal heart rate, the physiologic cost index, oxygen consumption, metabolic equivalents, and energy efficiency) were evaluated duringthe 6MWT and 30MWT. A usability evaluation questionnaire for walking devices was developed based on the International Organization for Standardization/International Electrotechnical Commission guidelines through expert consultation.Results The ReWalk-gait presented significant advantages in energy efficiency compared to KAFO-gait in the 6MWT and 30MWT; however, there were no differences in walking distance or speed in the 30MWT between ReWalk-gait and KAFOgait. The usability test demonstrated that ReWalk-gait was not superior to KAFO-gait in terms of safety, efficacy, efficiency, or patient satisfaction.Conclusion The robot (ReWalk) enabled patients with paraplegia to walk with lower energy consumption compared to KAFO, but the ReWalk-gait was not superior to KAFO-gaitin terms of patient satisfaction.

30 March 2026 in Physiotherapy Research International
Verified
Journal Article
Closed access
SASeung Heun An
Seung Heun An
EKEun Joo Kim
Eun Joo Kim
SYSung Phil Yang
Sung Phil Yang
JLJun Min Lee
Jun Min Lee