The recent emergence of wide bandgap power devices enables higher switching frequencies in electric motor drives. The subsequent possibility for higher efficiency and smaller size requires accurate prediction of harmonic losses in motors. Therefore, in this article, an original analysis of harmonic losses arising in inverter-fed two-pole slotless permanent-magnet machines with axially segmented ring magnets is presented. The developed three-dimensional time-efficient numerical model is successfully validated under high-speed no-load operation using a silicon carbide based three-phase inverter and rotors carrying a broad range of magnet segment thicknesses (3-12.6 mm). The model enables harmonic loss prediction capability (including loss separation) with an accuracy of 15% over a wide frequency range (8-120 kHz), which is a unique contribution. The sensitivity analysis primarily emphasizes the importance of taking into account the axial segmentation, and secondarily the rotor-shaft magnetoelasticity effects for accurate modeling of harmonic losses. The conducted case study demonstrates that wide bandgap transistors effectively can contribute to eliminating the need for inductive filters in motor drives.
11 June 2019 in IEEE Transactions on Industrial Electronics
This paper deals with the design and evaluation of a short-circuit rotor-ring for enhanced self-sensing capability in a 2-pole slotless permanent-magnet motor. High-frequency rotor anisotropy is enabled by adding a short-circuited rotor-ring. Optimal ring-dimensions are determined by parametric numerical studies. An effective high-frequency saliency of up to 1.8 is demonstrated. The steady-state estimation error is within 2%, practically unaffected by load (current) level due to the large effective air-gap. The proposed observer performs properly also during dynamic load changes. Fall-times from 3000 to 0 rpm in less than 50 ms with negligible overshoot are demonstrated. In contrast to slotted self-sensing electrical machinery, the examined slotless machine exhibits negliglible impair of angular estimation error with load. Also parasitic effects such as power losses, heating and torque ripple are analyzed.