Hidemi Okuma

Hidemi Okuma

Auto-generated profile, based on publicly available information

Hidemi Okuma

Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Korean Journal of Radiology
Verified
Journal Article
Open access
PDF file
MIMasanori Ishida
Masanori Ishida
WGWataru Gonoi
Wataru Gonoi
HOHidemi Okuma
Hidemi Okuma
GSGo Shirota
Go Shirota
YSYukako Shintani
Yukako Shintani
KOKuni Ohtomo
Kuni Ohtomo
Ishida M, et al. Korean J Radiol. 2015 Jul-Aug;16(4):798-809. https://doi.org/10.3348/kjr.2015.16.4.798

19 June 2017 in European Radiology
Verified
Journal Article
Closed access
PDF file
WGWataru Gonoi
Wataru Gonoi
THTakana Yamakawa Hayashi
Takana Yamakawa Hayashi
HOHidemi Okuma
Hidemi Okuma
MAMasaaki Akahane
Masaaki Akahane
YNYousuke Nakai
Yousuke Nakai
KOKuni Ohtomo
Kuni Ohtomo

27 September 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HOHidemi Okuma
Hidemi Okuma
WGWataru Gonoi
Wataru Gonoi
MIMasanori Ishida
Masanori Ishida
YSYukako Shintani
Yukako Shintani
YTYutaka Takazawa
Yutaka Takazawa
KOKuni Ohtomo
Kuni Ohtomo
To evaluate the postmortem changes of the heart wall on postmortem (PM) computed tomography (CT) in comparison with those on ante mortem CT (AMCT), and in comparison with the pathological findings, obtained in the same patients. We studied 57 consecutive patients who had undergone AMCT, PMCT, and pathological autopsy in our tertiary care hospital between April 2009 and December 2010. PMCT was performed within 20 hours after death, followed by pathological autopsy. The cardiac chambers were measured at five sites on both AMCT and PMCT by two board-certified radiologists who were not provided with clinical information. The differences in heart wall thickness between AMCT with and without contrast medium, between AMCT and PMCT, and between PMCT and pathological anatomy were evaluated statistically. Confounding factors of postmortem change such as gender, presence of arteriosclerosis, the organ related to cause of death, age, and elapsed time since death were examined statistically. No significant differences were observed on AMCT in comparison of contrasted and non-contrasted images. The heart wall was significantly thicker on PMCT than on AMCT (p < 0.0001) at all five measurement sites. The heart wall was significantly thicker on PMCT than on pathology specimens when measured in accordance with pathological standard mensuration. However, no significant difference was observed between PMCT measurements and those of pathology specimens at any site when the papillary muscles and epicardial fat were included. No significant association was found between postmortem change in heart wall thickness and gender, presence of arteriosclerosis, the organ related to cause of death, age, or elapsed time since death. This is the first longitudinal study to confirm greater thickness of heart wall on postmortem images compared with ante mortem images, in the same patients. Furthermore, the postmortem changes on CT were supported by the pathological findings.

1 May 2021 in European Journal of Radiology
Verified
Journal Article
Closed access
AIAleksandr Istomin
Aleksandr Istomin
AMAmro Masarwah
Amro Masarwah
RVRitva Vanninen
Ritva Vanninen
HOHidemi Okuma
Hidemi Okuma
MSMazen Sudah
Mazen Sudah

3 November 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
HOHidemi Okuma
Hidemi Okuma
WGWataru Gonoi
Wataru Gonoi
MIMasanori Ishida
Masanori Ishida
GSGo Shirota
Go Shirota
YSYukako Shintani
Yukako Shintani
KOKuni Ohtomo
Kuni Ohtomo
We evaluated the postmortem changes of striated muscle by comparing computed tomography (CT) images obtained postmortem and antemortem in the same patients. We studied 33 consecutive patients who underwent antemortem CT, postmortem CT, and pathological autopsy in our tertiary care hospital between April 2009 and December 2010. Postmortem CT was performed within 20 h after death and was followed by pathological autopsy. Pathological autopsy confirmed the absence of muscular diseases such as amyotrophic lateral sclerosis, muscular dystrophy, myositis, and myasthenia, in all of the patients. The CT attenuation values of four cardiac muscle sites (anterior wall of the left ventricle, left ventricular free wall, posterior wall of the left ventricle, and the ventricular septum) and two skeletal muscle sites (the pectoralis major muscle and the erector spinae muscle) were compared between antemortem and postmortem CT using paired t test. Striated muscle had significantly greater attenuation on postmortem CT than on antemortem CT (P<0.001) in all six tissue sites. No significant association was found between postmortem change in the CT attenuation of striated muscle and gender, age, or elapsed time since death. This is the first longitudinal study to show hyperattenuation of striated muscle on postmortem CT images compared with antemortem CT images in the same patients.

30 November 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GSGo Shirota
Go Shirota
WGWataru Gonoi
Wataru Gonoi
MIMasanori Ishida
Masanori Ishida
HOHidemi Okuma
Hidemi Okuma
YSYukako Shintani
Yukako Shintani
KOKuni Ohtomo
Kuni Ohtomo
The purpose of this study was to evaluate the brain by postmortem computed tomography (PMCT) versus antemortem computed tomography (AMCT) using brains from the same patients. We studied 36 nontraumatic subjects who underwent AMCT, PMCT, and pathological autopsy in our hospital between April 2009 and December 2013. PMCT was performed within 20 h after death, followed by pathological autopsy including the brain. Autopsy confirmed the absence of intracranial disorders that might be related to the cause of death or might affect measurements in our study. Width of the third ventricle, width of the central sulcus, and attenuation in gray matter (GM) and white matter (WM) from the same area of the basal ganglia, centrum semiovale, and high convexity were statistically compared between AMCT and PMCT. Both the width of the third ventricle and the central sulcus were significantly shorter in PMCT than in AMCT (P < 0.0001). GM attenuation increased after death at the level of the centrum semiovale and high convexity, but the differences were not statistically significant considering the differences in attenuation among the different computed tomography scanners. WM attenuation significantly increased after death at all levels (P<0.0001). The differences were larger than the differences in scanners. GM/WM ratio of attenuation was significantly lower by PMCT than by AMCT at all levels (P<0.0001). PMCT showed an increase in WM attenuation, loss of GM–WM differentiation, and brain swelling, evidenced by a decrease in the size of ventricles and sulci.