Huiyi Zuo

Huiyi Zuo

Auto-generated profile, based on publicly available information

Huiyi Zuo

Ophthalmology Department, First Affiliated Hospital of GuangXi Medical University, Nanning, 530021, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
HZHuiyi Zuo
Huiyi Zuo
BHBaoyu Huang
Baoyu Huang
JHJian He
Jian He
LFLiying Fang
Liying Fang
MHMinli Huang
Minli Huang
Background: In recent years, with the rapid development of machine learning (ML), it has gained widespread attention from researchers in clinical practice. ML models appear to demonstrate promising accuracy in the diagnosis of complex diseases, as well as in predicting disease progression and prognosis. Some studies have applied it to ophthalmology, primarily for the diagnosis of pathologic myopia and high myopia-associated glaucoma, as well as for predicting the progression of high myopia. ML-based detection still requires evidence-based validation to prove its accuracy and feasibility. Objective: This study aims to discern the performance of ML methods in detecting high myopia and pathologic myopia in clinical practice, thereby providing evidence-based support for the future development and refinement of intelligent diagnostic or predictive tools. Methods: PubMed, Cochrane, Embase, and Web of Science were thoroughly retrieved up to September 3, 2023. The prediction model risk of bias assessment tool was leveraged to appraise the risk of bias in the eligible studies. The meta-analysis was implemented using a bivariate mixed-effects model. In the validation set, subgroup analyses were conducted based on the ML target events (diagnosis and prediction of high myopia and diagnosis of pathological myopia and high myopia-associated glaucoma) and modeling methods. Results: This study ultimately included 45 studies, of which 32 were used for quantitative meta-analysis. The meta-analysis results unveiled that for the diagnosis of pathologic myopia, the summary receiver operating characteristic (SROC), sensitivity, and specificity of ML were 0.97 (95% CI 0.95-0.98), 0.91 (95% CI 0.89-0.92), and 0.95 (95% CI 0.94-0.97), respectively. Specifically, deep learning (DL) showed an SROC of 0.97 (95% CI 0.95-0.98), sensitivity of 0.92 (95% CI 0.90-0.93), and specificity of 0.96 (95% CI 0.95-0.97), while conventional ML (non-DL) showed an SROC of 0.86 (95% CI 0.75-0.92), sensitivity of 0.77 (95% CI 0.69-0.84), and specificity of 0.85 (95% CI 0.75-0.92). For the diagnosis and prediction of high myopia, the SROC, sensitivity, and specificity of ML were 0.98 (95% CI 0.96-0.99), 0.94 (95% CI 0.90-0.96), and 0.94 (95% CI 0.88-0.97), respectively. For the diagnosis of high myopia-associated glaucoma, the SROC, sensitivity, and specificity of ML were 0.96 (95% CI 0.94-0.97), 0.92 (95% CI 0.85-0.96), and 0.88 (95% CI 0.67-0.96), respectively. Conclusions: ML demonstrated highly promising accuracy in diagnosing high myopia and pathologic myopia. Moreover, based on the limited evidence available, we also found that ML appeared to have favorable accuracy in predicting the risk of developing high myopia in the future. DL can be used as a potential method for intelligent image processing and intelligent recognition, and intelligent examination tools can be developed in subsequent research to provide help for areas where medical resources are scarce. Trial Registration: PROSPERO CRD42023470820; https://tinyurl.com/2xexp738

22 February 2024 in JMIR Preprints
Verified
Preprint
Open access
HZHuiyi Zuo
Huiyi Zuo
BHBaoyu Huang
Baoyu Huang
JHJian He
Jian He
LFLiying Fang
Liying Fang
MHMinli Huang
Minli Huang
BACKGROUND In recent years, with the rapid development of machine learning (ML), it has gained widespread attention from researchers in clinical practice. ML models appear to demonstrate promising accuracy in the diagnosis of complex diseases, as well as in predicting disease progression and prognosis. Some studies have applied it to ophthalmology, primarily for the diagnosis of pathologic myopia and high myopia-associated glaucoma, as well as for predicting the progression of high myopia. ML-based detection still requires evidence-based validation to prove its accuracy and feasibility. OBJECTIVE This study aims to discern the performance of ML methods in detecting high myopia and pathologic myopia in clinical practice, thereby providing evidence-based support for the future development and refinement of intelligent diagnostic or predictive tools. METHODS PubMed, Cochrane, Embase, and Web of Science were thoroughly retrieved up to September 3, 2023. The prediction model risk of bias assessment tool was leveraged to appraise the risk of bias in the eligible studies. The meta-analysis was implemented using a bivariate mixed-effects model. In the validation set, subgroup analyses were conducted based on the ML target events (diagnosis and prediction of high myopia and diagnosis of pathological myopia and high myopia-associated glaucoma) and modeling methods. RESULTS This study ultimately included 45 studies, of which 32 were used for quantitative meta-analysis. The meta-analysis results unveiled that for the diagnosis of pathologic myopia, the summary receiver operating characteristic (SROC), sensitivity, and specificity of ML were 0.97 (95% CI 0.95-0.98), 0.91 (95% CI 0.89-0.92), and 0.95 (95% CI 0.94-0.97), respectively. Specifically, deep learning (DL) showed an SROC of 0.97 (95% CI 0.95-0.98), sensitivity of 0.92 (95% CI 0.90-0.93), and specificity of 0.96 (95% CI 0.95-0.97), while conventional ML (non-DL) showed an SROC of 0.86 (95% CI 0.75-0.92), sensitivity of 0.77 (95% CI 0.69-0.84), and specificity of 0.85 (95% CI 0.75-0.92). For the diagnosis and prediction of high myopia, the SROC, sensitivity, and specificity of ML were 0.98 (95% CI 0.96-0.99), 0.94 (95% CI 0.90-0.96), and 0.94 (95% CI 0.88-0.97), respectively. For the diagnosis of high myopia-associated glaucoma, the SROC, sensitivity, and specificity of ML were 0.96 (95% CI 0.94-0.97), 0.92 (95% CI 0.85-0.96), and 0.88 (95% CI 0.67-0.96), respectively. CONCLUSIONS ML demonstrated highly promising accuracy in diagnosing high myopia and pathologic myopia. Moreover, based on the limited evidence available, we also found that ML appeared to have favorable accuracy in predicting the risk of developing high myopia in the future. DL can be used as a potential method for intelligent image processing and intelligent recognition, and intelligent examination tools can be developed in subsequent research to provide help for areas where medical resources are scarce. CLINICALTRIAL PROSPERO CRD42023470820; https://tinyurl.com/2xexp738

3 July 2026 in BMC Ophthalmology
Verified
Journal Article
Open access
LFLiying Fang
Liying Fang
HZHuiyi Zuo
Huiyi Zuo
MHMinli Huang
Minli Huang
Central Serous Chorioretinopathy(CSC) is a chorioretinal disorder, predominantly affects young to middle-aged adults, resulting serious vision disorder. This study aimed to develop a Bayesian network model to predict the key factors influencing the early therapeutic efficacy of 577 nm-SML in patients with CSC. A total of 159 patients (159 eyes) diagnosed with CSC and treated with 577 nm-SML at the First Affiliated Hospital of Guangxi Medical University from January 2019 to November 2023 were retrospectively analyzed. Baseline data including age, sex, eye side, disease course, and past medical history were collected. Ophthalmic imaging detects central macular thickness (CMT), macular foveal volume (MFV within 1mm, 3mm, 6mm diameter), height and area of subretinal fluid (SRF), structural changes in the outer retinal layers (ORL), type and area of leakage lesions, etc. Influential variables significantly associated with 577nm-SML efficacy were screened using LASSO regression, then construct a Bayesian network model to predict factors that significantly affect the therapeutic effect. LASSO regression identified 19 significant variables related to treatment outcomes from the 40 possible risk factors included, including disease duration, sex, eye Side, smoking, hormone, macular foveal volumes (3 mm and 6 mm diameters), and the height and area of SRF, ORL integrity, typical PED, location of PED, location of RPE bulging, heterogeneity of NPL, HF of ORL, HF of choroid, leakage type, leakage location, leakage correlate with OCT. The Bayesian network presents complex interactions among these factors, shows that patients with smaller macular foveal volumes (within 3 mm diameter), shorter disease duration, and focal leakage exhibited superior responses to 577nm-SML treatment. The therapeutic response to 577nm-SML in CSC is influenced by multifactorial dynamics. Bayesian network can well present the complex network relationship between the therapeutic effect of 577nm-SML and related influencing factors, and identify potential risk factors that affect early efficacy.