Hudson Gasvoda

Hudson Gasvoda

Auto-generated profile, based on publicly available information

Hudson Gasvoda

Santa Clara University, Santa Clara, CA, United States

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2024
Verified
Conference Paper
Open access
MLMengchu Li
Mengchu Li
HGHanchen Gu
Hanchen Gu
YZYushen Zhang
Yushen Zhang
SLSiyuan Liang
Siyuan Liang
HGHudson Gasvoda
Hudson Gasvoda
USUlf Schlichtmann
Ulf Schlichtmann
Control channels on microfluidic large-scale integration (mLSI) chips are prone to blockage and leakage defects. In this work, we propose a built-in self-test (BIST) method that drastically improves the test efficiency. Given n to-be-tested control channels, we reduced the number of test patterns for blockage and leakage tests from [EQUATION] to 1, and from ⌈log2(n + 1)⌉ to ⌈log2(χ(G) + 1)⌉, respectively, where χ(G) denotes the vertex chromatic number of a graph G consisting of n vertices. We fabricated our design and demonstrated the feasibility and efficiency of our method.

6 December 2022 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
HGHudson Gasvoda
Hudson Gasvoda
NCNick Cmager
Nick Cmager
RARana Altay
Rana Altay
JLJu Young Lee
Ju Young Lee
IAIsmail Emre Araci
Ismail Emre Araci
Skin-strain-field is used as a fingerprint of the human movement to guide the design of an integrated strain sensor for digital human motion recognition.

23 June 2024
Verified
Conference Paper
Open access
SLSiyuan Liang
Siyuan Liang
YZYushen Zhang
Yushen Zhang
RARana Altay
Rana Altay
HGHudson Gasvoda
Hudson Gasvoda
MLMengchu Li
Mengchu Li
THTsung-Yi Ho
Tsung-Yi Ho
After decades of development, flow-based microfluidic biochips have become an increasingly attractive platform for biochemical experiments. The fluid transportation and the on-chip device operation are controlled by microvalves, which are driven by external pneumatic controllers. To meet the increasingly complex experimental demands, the number of microvalves has significantly increased, making it necessary to adopt multiplexers (MUXes) for the actuation of microvalves. However, existing MUX designs have limited coding capacities, resulting in area overhead and excessive chip-to-world interface. This paper proposes a novel gate structure for modifying the current MUX architecture, along with a mixed coding strategy that achieves the maximum coding capacity within the modified MUX architecture. Additionally, an efficient synthesis tool for the mixed-coding-based MUXes (LaMUXes) is presented. Experimental results demonstrate that the LaMUX is exceptionally efficient, substantially reducing the usage of pneumatic controllers and microvalves compared to existing MUX designs.

14 February 2025 in Advanced Sensor Research
Verified
Journal Article
Open access
HGHudson Gasvoda
Hudson Gasvoda
MLMengchu Li
Mengchu Li
APAndrea Pader
Andrea Pader
RARana Altay
Rana Altay
NCNick Cmager
Nick Cmager
IAIsmail Emre Araci
Ismail Emre Araci
An integrated strain sensor system that has a unique response to a specific (set of) human movement(s) has the potential to impact various musculoskeletal health tracking applications akin to the step counter's impact on physical activity tracking. It is determined that an open circuit state of a sensor can be used as such a unique response. With this consideration, a digital strain sensor (DigSS) that exhibits a binary (i.e., ON/OFF) response when a threshold strain level is exceeded is developed. The channel geometry dependence of the corner flow in capillaric strain sensors (CSS) resulting in an electrofluidic switch is used. It is demonstrated that through the coalescence and breakup of a liquid meniscus, DigSS operates for hundreds of cycles with a strain limit of detection of 0.0026. To facilitate integration, a linear optimization‐based computer‐aided design tool for the integrated DigSS (iDigSS) is created. Experimental validation shows that the iDigSS distinguishes a target strain‐field profile from 35 of 36 theoretically distinguishable profiles without requiring signal processing. Human subject trials demonstrate the system's ability to differentiate a specific shoulder movement from five others and to wirelessly record wrist extension counts and durations.