Tyler Bowman

Tyler Bowman

Auto-generated profile, based on publicly available information

Tyler Bowman

Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
TBTyler Bowman
Tyler Bowman
MEMagda El-Shenawee
Magda El-Shenawee
LCLucas K. Campbell
Lucas K. Campbell
This work presents experimental and analytical comparison of terahertz transmission and reflection imaging modes for assessing breast carcinoma in excised paraffin-embedded human breast tissue. Modeling for both transmission and reflection imaging is developed. The refractive index and absorption coefficient of the tissue samples are obtained. The reflection measurements taken at the system’s fixed oblique angle of 30° are shown to be a hybridization of TE and TM modes. The models are validated with transmission spectroscopy at fixed points on fresh bovine muscle and fat tissues. Images based on the calculated absorption coefficient and index of refraction of bovine tissue are successfully compared with the terahertz magnitude and phase measured in the reflection mode. The validated techniques are extended to 20 and 30 μm slices of fixed human lobular carcinoma and infiltrating ductal carcinoma mounted on polystyrene microscope slides in order to investigate the terahertz differentiation of the carcinoma with non-cancerous tissue. Both transmission and reflection imaging show clear differentiation in carcinoma versus healthy tissue. However, when using the reflection mode, in the calculation of the thin tissue properties, the absorption is shown to be sensitive to small phase variations that arise due to deviations in slide and tissue thickness and non-ideal tissue adhesion. On the other hand, the results show that the transmission mode is much less sensitive to these phase variations. The results also demonstrate that reflection imaging provides higher resolution and more clear margins between cancerous and fibroglandular regions, cancerous and fatty regions, and fibroglandular and fatty tissue regions. In addition, more features consistent with high power pathology images are exhibited in the reflection mode images.

14 February 2018 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
TBTyler Bowman
Tyler Bowman
TCTanny Chavez
Tanny Chavez
KKKamrul Khan
Kamrul Khan
JWJingxian Wu
Jingxian Wu
ACAvishek Chakraborty
Avishek Chakraborty
MEMagda El-Shenawee
Magda El-Shenawee
This paper investigates terahertz (THz) imaging and classification of freshly excised murine xenograft breast cancer tumors. These tumors are grown via injection of E0771 breast adenocarcinoma cells into the flank of mice maintained on high-fat diet. Within 1 h of excision, the tumor and adjacent tissues are imaged using a pulsed THz system in the reflection mode. The THz images are classified using a statistical Bayesian mixture model with unsupervised and supervised approaches. Correlation with digitized pathology images is conducted using classification images assigned by a modal class decision rule. The corresponding receiver operating characteristic curves are obtained based on the classification results. A total of 13 tumor samples obtained from 9 tumors are investigated. The results show good correlation of THz images with pathology results in all samples of cancer and fat tissues. For tumor samples of cancer, fat, and muscle tissues, THz images show reasonable correlation with pathology where the primary challenge lies in the overlapping dielectric properties of cancer and muscle tissues. The use of a supervised regression approach shows improvement in the classification images although not consistently in all tissue regions. Advancing THz imaging of breast tumors from mice and the development of accurate statistical models will ultimately progress the technique for the assessment of human breast tumor margins.

9 August 2018 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
TCTanny Chavez
Tanny Chavez
TBTyler Bowman
Tyler Bowman
JWJingxian Wu
Jingxian Wu
KBKeith Bailey
Keith Bailey
MEMagda El-Shenawee
Magda El-Shenawee

18 March 2017 in Journal of Infrared, Millimeter, and Terahertz Waves
Verified
Journal Article
Closed access
PDF file
TBTyler Bowman
Tyler Bowman
YWYuhao Wu
Yuhao Wu
JGJohn Gauch
John Gauch
LCLucas K. Campbell
Lucas K. Campbell
MEMagda El-Shenawee
Magda El-Shenawee

14 September 2017 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PDF file
TBTyler Bowman
Tyler Bowman
AWAlec Walter
Alec Walter
OSOlga Shenderova
Olga Shenderova
NNNicholas Nunn
Nicholas Nunn
GMGary McGuire
Gary McGuire
MEMagda El-Shenawee
Magda El-Shenawee
Terahertz (THz) imaging is effective in distinguishing between cancerous, healthy, and fatty tissues in breast tumors, but a challenge remains in the contrast between cancerous and fibroglandular (healthy) tissues. This work investigates carbon-based nanoparticles as potential contrast agents for THz imaging of breast cancer. Microdiamonds, nanodiamonds (NDs), and nanometer-scale onion-like carbon (OLC) are characterized with THz transmission spectroscopy in low-absorption backgrounds of polydimethylsiloxane or polyethylene. The refractive index and absorption coefficients are calculated based on the measured electric fields. NDs show little effect on the THz signal, microdiamonds express resonance-like, size-dependent absorption peaks, and OLC provides a uniform increase in the optical properties even at low concentration. Due to its strong interaction with THz frequencies and ability to be activated for selective binding to cancer cells, OLC is implemented into engineered three-dimensional breast tumor models composed of phantom tissue mimicking infiltrating ductal carcinoma surrounded by a phantom mimicking healthy fibroglandular tissue. This model is imaged using the THz reflection mode to examine the effectiveness of contrast agents for differentiation between the two tissue types. In both spectroscopy and imaging, a 10% concentration of OLC shows the strongest impact on the THz signal and holds promise as a THz contrast agent.

12 November 2024 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
TBTyler C. Bowman
Tyler C. Bowman
TKThomas Kmieciak
Thomas Kmieciak
LBLaura B. Biedermann
Laura B. Biedermann
The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. This article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.