Travis Dodd

Travis Dodd

Auto-generated profile, based on publicly available information

Travis Dodd

Health Products Regulation Group, Therapeutic Goods Administration, 27 Scherger Drive Fairbairn, Australian Capital Territory 2609, Australia

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2025 in Journal of Infection and Public Health
Verified
Journal Article
Open access
JWJackson Williams
Jackson Williams
LBLucan Baillie
Lucan Baillie
WCWayne Clancy
Wayne Clancy
TDTravis Dodd
Travis Dodd
KTKelly Tsang
Kelly Tsang
ACAmanda Craig
Amanda Craig
Respirators are an essential medical device vital to prevent the transmission of airborne illness between persons. This study presents an investigation conducted by the Therapeutic Goods Administration (TGA) into the particle filtration efficiency (PFE) performance of respirators supplied in Australia that were included as medical devices in the Australian Register of Therapeutic Goods (ARTG) throughout the COVID-19 pandemic or supplied to the TGA from other jurisdictions for compliance testing. A total of 400 real-world batches of respirators were tested against a rapid-screen PFE method developed by the TGA. The TGA analysed a respirator's ability to meet its claimed filtration efficiency with a statistical power analysis differentiated by the claimed PFE standard, country of manufacture, time of inclusion into the ARTG and respirators with surgical against non-surgical claims. Of the tested batches of respirators (n = 400), 70 % were compliant with the pre-set compliance criteria. The results indicate statistically significant PFE differences (p < 0.05) between respirators claiming the standards 42 CFR Part 84, AS 1716:2012, GB 19083: 2010 and EN 149:2001+ A1:2009 when tested against respirators claiming GB 2626:2006. There were no observed significant differences between the PFE of surgical and non-surgical respirators (p > 0.05). The findings of this study highlight the importance of ensuring respirators meet their claimed PFE level based on their claimed standard prior to manufacturer release. Further studies should be focussed on investigating the effect of respiratory protection devices and their claimed efficiency in clinical settings such as hospitals against aerosolised particulates using a range of respiratory protection devices.