11 March 2020 in Journal of Applied Physics
Polysulfone was shock loaded to pressures of 14.6–26.2 GPa in a series of gas gun-driven plate-impact experiments measuring material response with embedded electro-magnetic particle velocity gauges and optical velocimetry. The embedded electro-magnetic particle velocity gauges did not show a distinct two-wave structure but did show rounding that suggested a reaction but not a distinct separation of the reactants and product waves. In contrast, the transmission experiments fielded with optical velocimetry, with product pressures ranging from 21.0 to 26.2 GPa, showed well-defined two-wave structures due to shock-driven chemical decomposition of the polymer to products at a higher density. Distinct two-wave structures have not previously been published in literature during polymer compression; here, we observed these two-wave structures at both the polymer/lithium fluoride and polymer/polymethylmethacrylate interfaces. Hydrodynamic simulations of the experiments were performed using a newly constructed SESAME equation of state (EOS) for the polymer, a thermochemical EOS for the decomposition products, and an Arrhenius reaction rate model for the kinetics of the reaction. Simulation results also demonstrated two-wave structures but were unable to quantitatively reproduce either the embedded gauge or optical velocimetry data.
3 November 2021 in Journal of Applied Physics
Polymers are widely implemented materials often used for safety and security in our daily lives. However, we do not have a thorough understanding of the phase transformations of these materials when exposed to extreme condition, high strain rate events. To study polymers in these severe environments, we performed plate impact experiments that impart a one-dimensional shockwave, at high pressures and temperatures, to observe the materials response. Generally, velocimetry is the experimental diagnostic used to capture the movement of high velocity interfaces to then calculate the mechanical variables associated with shock compression. However, when a material undergoes a phase transition, such as between two crystalline phases or melting to decomposition during shock compression, velocimetry does not explicitly indicate what structural change occurred. At the Dynamic Compression Sector at the Advanced Photon Source, gas gun driven compression has been paired with x-ray diffraction, providing the ability to study both the shock parameters and structural changes concurrently. We explored high density polyethylene (HDPE) both on its reactants Hugoniot ( GPa) and within its transition region (24.3 GPa) where HDPE is hypothesized to decompose from reactants to products. With x-ray diffraction, we observed both polymer chain compression and crystal structure reorientation from orthorhombic to monoclinic above 6 GPa as well as either a possible phase change or chemical decomposition at 24.3 GPa. With these experiments, we were able to determine the crystalline and amorphous Hugoniot loci at pressures below the polymer transition region.
19 January 2023 in Journal of Applied Physics
We performed a series of six plate impact experiments on polyimide and modeled them using new reactant and products equations of state combined with an Arrhenius rate model. The first experiment was diagnosed with embedded electromagnetic velocity gauges through which we directly observed attenuation of the lead shock to an approximately constant state over a propagation distance of roughly 4 mm. Simulated gauge profiles were in excellent qualitative agreement with experiment and suggested a sluggish chemical reaction that did not proceed to completion. The remaining five experiments were conducted in a transmission geometry and diagnosed velocimetrically at the sample/window interface. All five of these yielded profiles with a sharp shock followed by a more gradual approach to maximum interface velocity that was “rounded” to varying degree. These profiles proved difficult to interpret unambiguously due to the convolution of the reactive wave upon first shock with reflection of the lead wave and reshock or release by the window. Comparison with thermochemical calculations strongly suggests that the point of maximum interface velocity corresponds to the equilibrium reshock or release locus. We discuss the implications of this point for the practice of impedance matching based on the reflected Hugoniot of reactive materials such as polymers. The reactant and thermochemical products equations of state are developmental SESAME tables 97710 and 97720, respectively.
21 September 2023 in Journal of Dynamic Behavior of Materials
2 May 2025 in Journal of Applied Physics
Understanding the initiation sensitivity of high explosives that have been damaged through mechanical or thermal insults is important to safely handling the material. The shock initiation sensitivity of polymer bonded explosive (PBX) 9501 has been extensively studied at ambient and non-ambient temperatures. However, changes in morphology that result from inefficient pressing of the material or applied heat to the high explosive have not been explored for PBX 9501. PBX 9501 was purposely pressed at low densities, resulting in initial densities of 1.81 and 1.50 g/cm3. The resultant morphology of the low-density pressed PBX 9501 was spherical-like voids. PBX 9501 was also thermally damaged by heating to 120, 150, and 170 °C, resulting in initial densities of 1.77, 1.73, and 1.56 g/cm3, respectfully. This method resulted in fractal-like damage to the material. We tested the shock initiation sensitivity by performing gas gun driven planar impact experiments with embedded electromagnetic gauges that allow for both the calculation of the input pressure, along with the direct measurement of the shock-to-detonation transition. At initial densities around ∼1.8 g/cm3, more similar to the initial pressing density of PBX 9501 at 1.83 g/cm3, both materials showed an increase in sensitivity with shorter shock-to-detonation transitions than pristine PBX 9501. It appears that the spherical-like voids resulted in the more sensitive high explosive. The lowest initial densities, ∼1.5 g/cm3, showed a significant shift in the shock-to-detonation distances. It appears that the two morphologies at these lower initial densities resulted in similar initiation sensitivities.