1 January 2020 in Advances in Civil Engineering
The determination of liquid limit is of great significance in the engineering classification of soil and the selection of the control standard of highway subgrade packing and compactness. Based on the research achievements of many scholars on the relationship between the shear strength and the depth of cone penetration in fall cone tests in the liquid limit tests, the process of penetration was analyzed according to the Law of Conservation of Energy, and the expression of K was derived. Then, the expression was verified by the experimental data of different scholars and the existing data of various countries and institutions. And, the results were also compared with those obtained by the previous scholars using limit equilibrium theory. The results indicate that the new expression is in good agreement with the experimental results. K can be predicted well. And so, the shear strength can be calculated based on the depth of cone penetration, and then, the experimental value of the shear strength can be compared with the calculated value through laboratory tests. The influence of cone weight and cone angle on the shear strength calculation was analyzed. In addition, the liquid limit index of different standards was discussed based on the expression of K, and suggestions on how to achieve relative combination of different codes and standards were raised, which was very helpful for international communication.
1 January 2020 in Advances in Civil Engineering
As the 2 m thick compacted clay liner with permeability coefficient of 1 × 10−7 cm/s is required in the Chinese technical specifications about landfill, the performance of this compacted clay liner was analyzed considering three different adsorption isotherms (convex, straight, and concave). The effects of source concentration, adsorption mode, and waterhead on the breakthrough curve and breakthrough time of Pb2+ were discussed. The results indicate that reducing the concentration of pollution sources is beneficial to prolonging the breakthrough time. With the waterhead of 10 m, the absolute breakthrough time, respectively, increased from 2.77 to 3.7 years (concave type isotherm), from 17.63 to 26.58 years (straight type isotherm), and from 35.43 to 59.6 years (convex type isotherm), as the source concentration decreased from 1000 mg/L to 10 mg/L. The effect of adsorption isotherm type on the performance of the barrier is very obvious: with the waterhead of 10 m, the absolute breakthrough time corresponding to the convex isotherm is more than twice that of the straight adsorption isotherm, and more than 12.8 times that of the concave isotherm. The absolute breakthrough time corresponding to 0.3 m waterhead is more than 4 times that of 10 m, and reducing the waterhead can effectively increase the breakthrough time.