Modular multilevel converter (MMC) is an attractive topology in industrial applications such as high-voltage direct current (HVdc) transmission system where fast power control is required. The most conventional control method for MMC uses cascaded structures, where the power transmission and internal energy dynamic (outer loops) is limited by the “frequency separation” constraints since the dynamic choice of the currents (inner loops) must consider the tradeoff between rapidity and robustness. In this article, we present a new control method based on a differential flatness theory. The main interest of the proposed control is the possibility to obtain a very high dynamic performance of the MMC power flow, even under noisy measurements and parametric disturbances. Using the well-known average model of the MMC, a flat output is proposed, proving the differential flatness property of the MMC. Trajectory tracking controllers of ac grid active and reactive power are proposed using input-state full-order linearization. Simulation results, including losses corresponding to a realistic case of on-shore, point-to-point HVdc interconnection, are presented to show the performance of the proposed control scheme even with strong measurement noise.
8 March 2024 in IEEE Transactions on Applied Superconductivity
The European project SCARLET aims to study and realize a demonstrator of a MVDC (Medium Voltage Direct Current) high-power superconducting cable. This device might be employed to connect offshore wind farms with land, expecting to significantly simplify the offshore platform by eliminating the need for its conversion function. For this purpose, windmill conversion chain must be modified to directly produce the MVDC export voltage. In this scenario, this paper presents the case of a 1GW offshore windmill superconducting link and outlines the design consideration for a 1 GW onshore converter. For this cable, a protection strategy that combines DC circuit breakers with a Resistive Superconducting Fault Current Limiter is proposed. Moreover, this works demonstrates how a superconducting cable can be modelled as an electrical circuit to be integrated into a network simulation tool, enabling the investigation of various fault scenarios and protection strategies. Finally, a specific result is discussed to exemplify how the proposed approach can benefit the design of both the electrical network and the superconducting cable itself.
The success of modular multilevel converters (MMCs) in high-voltage direct current (HVDC) applications has fueled the research on modular converter topologies. New modular converter topologies are often proposed, discussed, and sometimes applied in HVDC, as well as other industrial application such as STATCOMs, DC/DC HVDC, medium-voltage direct current (MVDC), etc. The performance evaluation of new modular converter topologies is a complex and time-consuming process that typically involves dynamic simulations and the design of a control system for the new converter topology. Sadly, many topologies do not progress to the implementation stage. This paper proposes a set of key performance indicators (KPIs) related to the cost and footprint of the converter and a procedure designed to rapidly evaluate these indicators for new converter topologies. The proposed methodology eliminates the need for dynamic simulations and control-system design, and is capable of identifying whether a particular converter is worth considering or not for further studies of a specific application, depending on the operating requirements. Thanks to the method outlined in this work and via the key parameters quantifying the “relevance” of the analyzed converters, promising topologies were easily identified, while the others could be rapidly discarded, resulting in saving valuable time in the study of the solutions that have a real potential. The proposed method is first described from a general point of view and then applied to a case study of the new converter topology—Open-Delta CLSC—and its application in two use cases.
18 February 2025 in IEEE Transactions on Applied Superconductivity
DC power transmission technologies have achieved significant advancements, gaining widespread adoption within modern electrical systems. The use of superconducting cables in Magnesium Diboride (MgB2) cooled by liquid hydrogen (LH2) could drastically increase the performance of DC grids, enabling higher power transport capacity and extending transmission distance, while reducing energy loss and land occupation. Today, the transport of DC electrical energy is enabled through modular muti-level converters (MMCs) capable of effectively controlling currents, voltages and power flow. Designing an optimal DC power system, along with appropriate superconducting cable design and protection apparatus, needs accurate, yet simplified, models of the converters. This study presents simplified models that apply during the fault, able to adapt to any pre-fault scenario without a need to implement complex control systems. The developed model can be easily integrated, along with a model of a superconducting MgB2 cable, in EMT power system simulators for analysing their mutual interaction during faults and for optimizing the cable design and its protection system.
The European project SCARLET aims to study and realize a demonstrator of a MVDC (Medium Voltage Direct Current) high-power superconducting cable. This device might be employed to connect offshore wind farms with land, expecting to significantly simplify the offshore platform by eliminating the need for its conversion function. For this purpose, windmill conversion chain must be modified to directly produce the MVDC export voltage. In this scenario, this paper presents the case of a 1GW offshore windmill superconducting link and outlines the design consideration for a 1 GW onshore converter. For this cable, a protection strategy that combines DC circuit breakers with a Resistive Superconducting Fault Current Limiter is proposed. Moreover, this works demonstrates how a superconducting cable can be modelled as an electrical circuit to be integrated into a network simulation tool, enabling the investigation of various fault scenarios and protection strategies. Finally, a specific result is discussed to exemplify how the proposed approach can benefit the design of both the electrical network and the superconducting cable itself.