Guillaume Montemont

Guillaume Montemont

Auto-generated profile, based on publicly available information

Guillaume Montemont

CEA-LETI, Grenoble, France

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 December 2004 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
LVL. Verger
L. Verger
MGM.C. Gentet
M.C. Gentet
LGL. Gerfault
L. Gerfault
RGR. Guillemaud
R. Guillemaud
CMC. Mestais
C. Mestais
JRJ. Rustique
J. Rustique
We present techniques and systems for a CZT gamma camera head based on an array of discrete CZT detectors and associated front-end electronics. In Section I, we describe the performance of a small 256 detector (16 /spl times/ 16) CZT imager in terms of homogeneity, energy resolution, and detection efficiency. The array is composed of groups of 16 single detectors (4/spl times/4/spl times/6 mm/sup 3/ each), each group served by a 16-channel multiplexed ASIC preamplifier. The electron bi-parametric (BP) spectrum with the depth of interaction information is used to improve detection efficiency. The present work compares the performance (sensitivity, spatial resolution, and contrast) of this small prototype imager and an Anger NaI(Tl) scintillation gamma camera using phantom images with small cold zones in a high-scatter environment. In Section II, we present an approach to the next generation of this technology, a gamma camera with a segmented monolithic CZT detector associated with the electron BP spectrum, which also allows correction for spectral tailing and dramatically improves both detection efficiency and energy resolution. Results with and without BP correction are given for a 10/spl times/10/spl times/5 mm/sup 3/ CZT monolithic detector (16 pixels, 2 /spl times/ 2 mm pixel, and 2.5-mm pitch) associated with 16 individual ASIC preamplifiers: an energy resolution close to 2% FWHM at 122 keV has been obtained on 16 pixels after BP correction.

1 February 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
LVLoïck Verger
Loïck Verger
EGEric Gros-Daillon
Eric Gros-Daillon
OMOlivier Monnet
Olivier Monnet
GMGuillaume Montémont
Guillaume Montémont
BPBernard Pelliciari
Bernard Pelliciari

24 September 2014 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
GMGuillaume Montemont
Guillaume Montemont
SLSilvere Lux
Silvere Lux
OMOlivier Monnet
Olivier Monnet
SSSylvain Stanchina
Sylvain Stanchina
LVLoick Verger
Loick Verger
CZT detectors are the basic building block of a variety of new SPECT systems. Their modularity allows adapting system architecture to specific applications such as cardiac, breast, brain or small animal imaging. In semiconductors, a high number of electron-hole pairs is produced by a single interaction. This direct conversion process allows better energy and spatial resolutions than usual scintillation detectors based on NaI(Tl). However, it remains often unclear if SPECT imaging can really benefit of that performance gain. We investigate the system performance of a detection module, which is based on 5 mm thick CZT with a segmented anode having a 2.5 mm pitch by simulation and experimentation. This pitch allows an easy assembly of the crystal on the readout board and limits the space occupied by electronics without significantly degrading energy and spatial resolution.

1 February 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
ADArnaud Drezet
Arnaud Drezet
OMOlivier Monnet
Olivier Monnet
FMFrançoise Mathy
Françoise Mathy
GMGuillaume Montemont
Guillaume Montemont
LVLoïck Verger
Loïck Verger

19 April 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
Charlotte RobertCharlotte Robert
Charlotte Robert
GMGuillaume Montémont
Guillaume Montémont
VRVéronique Rebuffel
Véronique Rebuffel
IBIrene Buvat
Irene Buvat
LGLucie Guérin
Lucie Guérin
LVLoïck Verger
Loïck Verger
A new gamma-camera architecture named HiSens is presented and evaluated. It consists of a parallel hole collimator, a pixelated CdZnTe (CZT) detector associated with specific electronics for 3D localization and dedicated reconstruction algorithms. To gain in efficiency, a high aperture collimator is used. The spatial resolution is preserved thanks to accurate 3D localization of the interactions inside the detector based on a fine sampling of the CZT detector and on the depth of interaction information. The performance of this architecture is characterized using Monte Carlo simulations in both planar and tomographic modes. Detective quantum efficiency (DQE) computations are then used to optimize the collimator aperture. In planar mode, the simulations show that the fine CZT detector pixelization increases the system sensitivity by 2 compared to a standard Anger camera without loss in spatial resolution. These results are then validated against experimental data. In SPECT, Monte Carlo simulations confirm the merits of the HiSens architecture observed in planar imaging.

13 September 2018 in Proceedings of SPIE
Verified
Conference Paper
Closed access
PDF file
HCHenry Chen
Henry Chen
HLHandong Li
Handong Li
ASArun G. Sundaram
Arun G. Sundaram
MRMichael D. Reed
Michael D. Reed
JEJohn Eger
John Eger
YZYuefeng Zhu
Yuefeng Zhu
Recent progress with Cadmium Zinc Telluride (CZT) radiation sensors grown by the traveling heater method (THM) at Kromek is reported. Large volume monolithic pixelated detectors, 40×40×15 mm3 have been fabricated with good initial gamma spectroscopy response (< 2.5% energy resolution at 662 keV at room temperature without correction). After depth of interaction (DOI) correction, detector performance with < 1% energy resolution at 662 keV at room temperature has been obtained on pixelated 22×22×15 mm3 CZT detector. For medical imaging applications, 20×20×6 mm3 pixelated detectors exhibits < 3% energy resolution at 122 keV without correction. These results have been achieved via our proprietary THM crystal growth in combination with our robust device fabrication technique. Examples of progress in other areas of CZT development for gamma spectroscopy and imaging applications such as 40×40×5 mm3 cross-strip device for PET and Kromek’s general-purpose SPECT camera will also be presented.