Ning Sheng

Ning Sheng

Auto-generated profile, based on publicly available information

Ning Sheng

Department of Orthopedics, Guizhou Provincial People's Hospital, Guiyang, 550000, Guizhou, People's Republic of China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 October 2023 in Materials Today Bio
Verified
Journal Article
Open access
NSNing Sheng
Ning Sheng
Fei XingFei Xing
Fei Xing
JWJie Wang
Jie Wang
QZQing-Yi Zhang
Qing-Yi Zhang
RNRong Nie
Rong Nie
HXHui-Qi Xie
Hui-Qi Xie
Bone regeneration following trauma, tumor resection, infection, or congenital disease is challenging. Diabetes mellitus (DM) is a metabolic disease characterized by hyperglycemia. It can result in complications affecting multiple systems including the musculoskeletal system. The increased number of diabetes-related fractures poses a great challenge to clinical specialties, particularly orthopedics and dentistry. Various pathological factors underlying DM may directly impair the process of bone regeneration, leading to delayed or even non-union of fractures. This review summarizes the mechanisms by which DM hampers bone regeneration, including immune abnormalities, inflammation, reactive oxygen species (ROS) accumulation, vascular system damage, insulin/insulin-like growth factor (IGF) deficiency, hyperglycemia, and the production of advanced glycation end products (AGEs). Based on published data, it also summarizes bone repair strategies in diabetic conditions, which include immune regulation, inhibition of inflammation, reduction of oxidative stress, promotion of angiogenesis, restoration of stem cell mobilization, and promotion of osteogenic differentiation, in addition to the challenges and future prospects of such approaches.

20 September 2023 in Composites Part B: Engineering
Verified
Journal Article
Closed access
RNRong Nie
Rong Nie
QZQing-Yi Zhang
Qing-Yi Zhang
JTJie Tan
Jie Tan
ZFZi-Yuan Feng
Zi-Yuan Feng
KHKai Huang
Kai Huang
HXHui-Qi Xie
Hui-Qi Xie

13 December 2023 in Chemical Engineering Journal
Verified
Journal Article
Closed access
NSNing Sheng
Ning Sheng
FXFei Xing
Fei Xing
QZQing-Yi Zhang
Qing-Yi Zhang
JTJie Tan
Jie Tan
RNRong Nie
Rong Nie
HXHui-Qi Xie
Hui-Qi Xie

21 December 2022 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
QWQiuke Wang
Qiuke Wang
NSNing Sheng
Ning Sheng
JHJen-Tai Huang
Jen-Tai Huang
HZHongyi Zhu
Hongyi Zhu
MTMaimaitiaili Tuerxun
Maimaitiaili Tuerxun
YCYunfeng Chen
Yunfeng Chen
Background: Previous observational studies and meta-analyses have recommended augmentation with a fibular allograft (FA) during the treatment of proximal humeral fractures with locking plates (LPs). However, to our knowledge, randomized controlled trials comparing open reduction and internal fixation (ORIF) with and without FA have not been performed to date. Methods: This was a randomized controlled trial in which adults with a medial column comminuted proximal humeral fracture were randomly allocated to undergo ORIF with an LP (the LP group) or with an LP augmented with an FA (the FA group). Patients were followed for 24 months. The primary outcome was the Disabilities of the Arm, Shoulder and Hand (DASH) score at 12 months after the surgical procedure. The secondary outcomes included the DASH score at other time points, shoulder function, pain score, satisfaction, complications, and changes in neck-shaft angle and humeral head height. Results: From October 20, 2016, to December 24, 2019, 80 patients were randomized. There were 52 women (65%), and the mean patient age (and standard deviation) was 65 ± 14 years. Of the 80 patients, 39 were allocated to the FA group and 41 were allocated to the LP group. At the primary time point (12 months), the unadjusted mean between-group difference in DASH score was −1.2 (95% confidence interval [CI], −7.3 to 5.0; p = 0.71) favoring the FA group, and, with adjustment for smoking, alcohol drinking, and diabetes, the between-group difference was −1.4 (95% CI, −7.7 to 5.0; p = 0.67) favoring FA. No significant differences between the 2 groups were found among the secondary outcomes. Conclusions: No additional benefit was found for FA augmentation in treating medial column comminuted proximal humeral fractures. Level of Evidence: Therapeutic Level II. See Instructions for Authors for a complete description of levels of evidence.

1 December 2020 in The Bone & Joint Journal
Verified
Journal Article
Open access
QWQiuke Wang
Qiuke Wang
NSNing Sheng
Ning Sheng
BRBiyu Rui
Biyu Rui
YCYunfeng Chen
Yunfeng Chen
Aims: The aim of this study was to explore why some calcar screws are malpositioned when a proximal humeral fracture is treated by internal fixation with a locking plate, and to identify risk factors for this phenomenon. Some suggestions can be made of ways to avoid this error. Methods: We retrospectively identified all proximal humeral fractures treated in our institution between October 2016 and October 2018 using the hospital information system. The patients’ medical and radiological data were collected, and we divided potential risk factors into two groups: preoperative factors and intraoperative factors. Preoperative factors included age, sex, height, weight, body mass index, proximal humeral bone mineral density, type of fracture, the condition of the medial hinge, and medial metaphyseal head extension. Intraoperative factors included the grade of surgeon, neck-shaft angle after reduction, humeral head height, restoration of medial support, and quality of reduction. Adjusted binary logistic regression and multivariate logistic regression models were used to identify pre- and intraoperative risk factors. Area under the curve (AUC) analysis was used to evaluate the discriminative ability of the multivariable model. Results: Data from 203 patients (63 males and 140 females) with a mean age of 62 years (22 to 89) were analyzed. In 49 fractures, the calcar screw was considered to be malpositioned; in 154 it was in the optimal position. The rate of malpositioning was therefore 24% (49/203). No preoperative risk factor was found for malpositioning of the calcar screws. Only the neck-shaft angle was found to be related to the risk of screw malpositioning in a multivariate model (with an AUC of 0.72). For the fractures in which the neck-shaft angle was reduced to between 130° and 150°, 91% (133/46) of calcar screws were in the optimal position. Conclusion: The neck-shaft angle is the key factor for the appropriate positioning of calcar screws when treating a proximal humeral fracture with a locking plate. We recommend reducing the angle to between 130° and 150°. Cite this article: Bone Joint J 2020;102-B(12):1629–1635.