Philip J. PT Blatt

Philip J. PT Blatt

Auto-generated profile, based on publicly available information

Philip J. PT Blatt

Department of Medicine, Oregon Health and Science University, Portland

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2008 in Journal of Neurologic Physical Therapy
Verified
Journal Article
Open access
PBPhilip J. PT Blatt
Philip J. PT Blatt
MSMichael C. Schubert
Michael C. Schubert
KRKathryn Elizabeth Roach
Kathryn Elizabeth Roach
RTRonald J. Tusa
Ronald J. Tusa
Objective: To establish intrarater and interrater reliability of the Vestibular Autorotation Test (VAT) (Western Systems Research Inc., Pasadena, CA) in a clinical sample of individuals reporting dizziness. Study Design: Ninety-eight patients with reports of dizziness referred for vestibular function testing performed repeated trials of horizontal VAT. A subsample of 49 individuals repeated the test for a second rater. Results: Approximately 66% of subjects were unable to meet the performance criterion of six consecutive trials where data was displayed at frequencies ≥3.9 Hz with coherence values held constant trial to trial. There was a good level of intrarater reliability for gain independent of the effects of practice (intraclass correlation coefficient [ICC] = 0.78 [95% confidence interval [CI]: 0.69–0.87] to 0.95 [(95% CI: 0.93–0.97]). A significant difference in intrarater reliability was found when the first three trials were compared to the last three trials for phase (ICC ranged from 0.04 [95% CI: 0.00–0.31] to 0.96 [95% CI: 0.93–0.97]) and asymmetry (ICC ranged from 0.39 [95% CI: 0.17–0.56] to 0.73 [95% CI: 0.32–0.81]) particularly at frequencies ≥4.3 Hz. Interrater reliability was good to excellent across all variables at frequencies ≤3.9 Hz. Conclusions: Many patients had difficulty performing the VAT. The reliability estimates for phase and asymmetry, but not gain, were significantly affected by practice. Careful attention to patient preparation, instruction, and test monitoring including sufficient patient practice before data collection are likely to be critical factors to ensure quality data.

1 January 2022 in The American Journal of Medicine
Verified
Journal Article
Closed access
CRChristine Rutlen
Christine Rutlen
PBPhilip Blatt
Philip Blatt
TKTaesoo Kim
Taesoo Kim
JBJoel Burnett
Joel Burnett