1 September 2014 in Otology & Neurotology
Hypothesis Human round window (RW) presents anatomic variations that may influence surgical approach. Background The true shape of the human RW has been divisive since its first description in 1772 by Antonio Scarpa. Introduction of novel surgical strategies in recent years have raised its significance. Here, the human RW size and shape variations were documented in microdissected human temporal bones. Methods An archival collection of human microdissected temporal bones was analyzed. RW rim could be delineated and photographed from the labyrinthine aspect and its topography assessed. Results Human RW is seldom round but ovoid or orthogonal, skewed, and nonplanar (saddlelike). Membrane is fan shaped or conical with an anteroinferior and a posterosuperior part. The mean longest diameter was 1.90 mm, and the smallest one is 1.54 mm. The mean diameter from the crista fenestra was 1.31 mm. The mean area of the RW was 2.08 mm2, which varied between 0.99 and 3.20 mm2. The crista fenestrae of the anterior component form a “doorstep” that may limit the entry to the scala tympani from the RW niche. Conclusion The alternate anatomic features of the human RW may influence its surgical access and designs of implants aimed at targeting this region.
1 January 2015 in Neuroscience
Human auditory nerve afferents consist of two separate systems; one is represented by the large type I cells innervating the inner hair cells and the other one by the small type II cells innervating the outer hair cells. Type I spiral ganglion neurons (SGNs) constitute 96% of the afferent nerve population and, in contrast to other mammals, their soma and pre- and post-somatic segments are unmyelinated. Type II nerve soma and fibers are unmyelinated. Histopathology and clinical experience imply that human SGNs can persist electrically excitable without dendrites, thus lacking connection to the organ of Corti. The biological background to this phenomenon remains elusive. We analyzed the pre- and post-somatic segments of the type I human SGNs using immunohistochemistry and transmission electron microscopy (TEM) in normal and pathological conditions. These segments were found surrounded by non-myelinated Schwann cells (NMSCs) showing strong intracellular expression of laminin-β2/collagen IV. These cells also bordered the perikaryal entry zone and disclosed surface rugosities outlined by a folded basement membrane (BM) expressing laminin-β2 and collagen IV. It is presumed that human large SGNs are demarcated by three cell categories: (a) myelinated Schwann cells, (b) NMSCs and (c) satellite glial cells (SGCs). Their BMs express laminin-β2/collagen IV and reaches the BM of the sensory epithelium at the habenula perforata. We speculate that the NMSCs protect SGNs from further degeneration following dendrite loss. It may give further explanation why SGNs can persist as electrically excitable monopolar cells even after long-time deafness, a blessing for the deaf treated with cochlear implantation.
4 November 2014 in Audiology and Neurotology
Background: The optimal insertion route for an electrode array in hearing preservation cochlear implantation (CI) surgery is still tentative. Both cochleostomy (CO) and round window (RW) techniques are used today. In the present study we analyzed size variations and topographic anatomy of the ‘hook' region of the human cochlea to better comprehend the Testo effects of various electric array insertion modes. Material and Methods: Size variations of the cochlear ‘hook' region were assessed in 23 human, microdissected temporal bones by measuring the distances between the oval and round windows, also outlining the spiral ligament/spiral lamina. Influence of size variations on spiral ligament position and fundamentals for different surgical approaches were evaluated in a subset of ‘small' and ‘large' cochleae performing different types of CO. In addition, the relationship between the microdissected accessory canal housing the inferior cochlear vein and the RW was analyzed. Results: The lateral vestibular wall and the cochlear ‘hook' displayed large anatomic variations that greatly influenced the size of the potential surgical area. Results showed that only very inferiorly located CO entered the scala tympani without causing trauma to the spiral ligament and spiral lamina. An inferior approach may challenge the inferior cochlear vein. Conclusion: Preoperative assessment of the distance between the round and oval windows may direct the surgeon before CI hearing-preservation surgery. CO techniques, especially in ‘small' ears, may lead to frequent damage to the inner ear structures. In those cases with substantial residual hearing, CI surgery may be better performed through a RW approach. i 2014 S. Karger AG, Basel
1 July 2018 in Autoimmunity Reviews
1 December 2009 in International Journal of Pediatric Otorhinolaryngology
7 February 2015 in Cell and tissue research
Introduction Cochlear micromechanics and frequency tuning depend on the macromolecular organization of the basilar membrane (BM), which is still unclear in man. Novel techniques in cochlear implantation (CI) motivate further analyses of the BM. Materials and methods Normal cochleae from patients undergoing removal of life-threatening petro-clival meningioma and an autopsy specimen from a normal human were used. Laser-confocal microscopy, high resolution scanning (SEM) and transmission electron microscopy (TEM) were carried out in combination. In addition, one human temporal bone was decellularized and investigated by SEM. Results The human BM consisted in four separate layers: (1) epithelial basement membrane positive for laminin-β2 and collagen IV, (2) BM “proper” composed of radial fibers expressing collagen II and XI, (3) layer of collagen IV and (4) tympanic covering layer (TCL) expressing collagen IV, fibronectin and integrin. BM thickness varied both radially and longitudinally (mean 0.55–1.16 μm). BM was thinnest near the OHC region and laterally. Conclusions There are several important similarities and differences between the morphology of the BM in humans and animals. Unlike in animals, it does not contain a distinct pars tecta (arcuate) and pectinata. Its width increases and thickness decreases as it travels apically in the cochlea. Findings show that the human BM is thinnest and probably most vibration-sensitive at the outer pillar feet/Deiter cells at the OHCs. The inner pillar and IHCs seem situated on a fairly rigid part of the BM. The gradient design of the BM suggests that its vulnerability increases apical wards when performing hearing preservation CI surgery.