We utilized 251 measurements from a recently developed automated seepage meter (ASM) in streambeds in the Nebraska Sand Hills, USA to investigate the small‐scale spatial variability of groundwater seepage flux (q) and the ability of the ASM to estimate mean q at larger scales. Small‐scale spatial variability of q was analyzed in five dense arrays, each covering an area of 13.5–28.0 m2 (169 total point measurements). Streambed vertical hydraulic conductivity (K) was also measured. Results provided: (a) high‐resolution contour plots of q and K, (b) anisotropic semi‐variograms demonstrating greater correlation scales of q and K along the stream length than across the stream width, and (c) the number of rows of points (perpendicular to streamflow) needed to represent the groundwater flux of areas up to 28.0 m2. The findings suggest that representative streambed measurements are best conducted perpendicular to streamflow to accommodate larger seepage flux heterogeneity in this direction and minimize sampling redundancy. To investigate the ASM's ability to produce accurate mean q at larger scales, seepage meters were deployed in four stream reaches (170–890 m), arranged in three to six transects (three to eight points each) per reach across the channel. In each reach, the mean seepage flux from ASMs was compared to the seepage flux from bromide tracer dilution. Agreement between the two methods indicates the viability of a modest number of seepage meter measurements to determine the overall groundwater flux to the stream and can guide sampling for solutes and environmental tracers.
Groundwater transit time distributions (TTDs) describe the spectrum of flow‐weighted apparent ages of groundwater from aquifer recharge to discharge. Regional‐scale TTDs in stream baseflow are often estimated from numerical models with limited calibration from groundwater sampling and suggest much younger groundwater discharge than has been observed by discrete age‐dating techniques. We investigate both local and regional‐scale groundwater TTDs in the Upper Middle Loup watershed (5,440 km2) overlying the High Plains Aquifer in the Nebraska Sand Hills, USA. We determined flow‐weighted apparent ages of groundwater discharging through the streambed at 88 discrete points along a 99 km groundwater‐dominated stream segment using 3H, noble gases, 14C, and groundwater flux measurements at the point‐scale (3,000 years. TTDs from upstream sampling areas were best fit by distributions with a narrow range of apparent ages, but when older groundwater from downstream sampling areas is included, the regional TTD is scale dependent and the distribution is better described by a gamma model (α ≈ 0.4) which accommodates large fractions of millennial‐aged groundwater. Observations indicate: (a) TTDs can exhibit spatial variability within a watershed and (b) watersheds can discharge larger fractions of old groundwater (>1,000 years) than commonly assumed.
A new approach for measuring fluxes across surface water—groundwater interfaces was recently proposed. The Automatic Seepage Meter (ASM) is equipped with a precise water level sensor and digital memory that analyzes water level time series in a vertical tube inserted into a streambed (Solomon et al., 2020, https://doi.org/10.1029/2019WR026983). The ability to infer flux values with high temporal resolution relies on an accurate interpretation of water level dynamics inside the tube. Here, we reduce the three‐dimensional hydrodynamic problem that describes the ASM water level in a variety of field conditions to a single ordinary differential equation. This novel general analytical solution for estimating ASM responses is more comprehensive and flexible than previous approaches and is applicable to the entire range of field conditions, including steady or transient stream stages, evaporation, rainfall, and noise. For example, our analysis determines the timing of the nonmonotonic ASM response to a monotonic linear stream stage variation and explains previously used empirical parabolic approximation for estimating fluxes. We present algorithms for simultaneous inference of vertical interface flux and hydraulic conductivity values together with an example code. We quantify how the accuracy of parameter estimation depends on test duration and noise amplitude and propose how our analysis can be used to optimize field test protocols. On this basis, changing the ASM geometry by increasing the radius and decreasing tube insertion depth may enable ASM field test protocols that estimate interface flux and hydraulic conductivity faster while maintaining desired accuracy. Potential applications of joint parameter estimation are suggested.
Simultaneous short-pulse injections of two tracers (sodium bromide [Br–] and fluorescein dye) were made in a losing reach of Snake Creek in Great Basin National Park, Nevada, USA, to evaluate the quantity of stream loss through permeable carbonates that resurfaces at a spring approximately 10 km down drainage. A revised hydrogeologic cross section for a possible flow path of the infiltrated Snake Creek water is presented, and the results may inform water management in the region. First arrival and peak concentration of the two tracers occurred at 9.5 and 12.7 days after injection, respectively. Fracture transport simulations indicate that Br– preferentially diffuses into immobile regions of the aquifer, and this diffusive flux is likely responsible for the major differences in the breakthrough curves. When considering the diffusive tracer flux, total apparent Br– and fluorescein dye recoveries were 16.9–22.1% and 21.7–24.3%, respectively. These findings imply that consideration of diffusive flux and long-term monitoring in fracture-dominated flow may support accurate quantification of tracer recovery. In addition, the apparent power law slopes of the breakthrough tails for both tracers were steeper at early times than have been attributed to heterogeneous advection or channeling in meter-scale tests, but the late-time Br– power law slope becomes less steep than has been attributed to diffusive exchange. These deviations may reflect fracture transport patterns that occur at larger scales.