Yuting Chen

Yuting Chen

Auto-generated profile, based on publicly available information

Yuting Chen

Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, Hubei, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
HZHaobo Zhang
Haobo Zhang
PZPeng Zhang
Peng Zhang
ZWZhiwei Wang
Zhiwei Wang
LCLianying Chao
Lianying Chao
YCYuting Chen
Yuting Chen
QLQiang Li
Qiang Li
The heart sound reflects the movement status of the cardiovascular system and contains the early pathological information of cardiovascular diseases. Automatic heart sound diagnosis plays an essential role in the early detection of cardiovascular diseases. In this study, we aim to develop a novel end-to-end heart sound abnormality detection and classification method, which can be adapted to different heart sound diagnosis tasks. Specifically, we developed a Multi-feature Decision Fusion Network (MDFNet) composed of a Multi-dimensional Feature Extraction (MFE) module and a Multi-dimensional Decision Fusion (MDF) module. The MFE module extracted spatial features, multi-level temporal features and spatial-temporal fusion features to learn heart sound characteristics from multiple perspectives. Through deep supervision and decision fusion, the MDF module made the multi-dimensional features extracted by the MFE module more discriminative, and fused the decision results of multi-dimensional features to integrate complementary information. Furthermore, attention modules were embedded in the MDFNet to emphasize the fundamental heart sounds containing effective feature information. Finally, we proposed an efficient data augmentation method to circumvent the diagnosis performance degradation caused by the lack of cardiac cycle segmentation in other end-to-end methods. The developed method achieved an overall accuracy of 94.44% and a F1-score of 86.90% on the binary classification task and a F1-score of 99.30% on the five-classification task. Our method outperformed other state-of-the-art methods and had good clinical application prospects.

27 September 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PZPeng Zhang
Peng Zhang
LCLianying Chao
Lianying Chao
YCYuting Chen
Yuting Chen
XMXuan Ma
Xuan Ma
WWWeihua Wang
Weihua Wang
QLQiang Li
Qiang Li
Background: For the nonstationarity of neural recordings in intracortical brain–machine interfaces, daily retraining in a supervised manner is always required to maintain the performance of the decoder. This problem can be improved by using a reinforcement learning (RL) based self-recalibrating decoder. However, quickly exploring new knowledge while maintaining a good performance remains a challenge in RL-based decoders. Methods: To solve this problem, we proposed an attention-gated RL-based algorithm combining transfer learning, mini-batch, and weight updating schemes to accelerate the weight updating and avoid over-fitting. The proposed algorithm was tested on intracortical neural data recorded from two monkeys to decode their reaching positions and grasping gestures. Results: The decoding results showed that our proposed algorithm achieved an approximate 20% increase in classification accuracy compared to that obtained by the non-retrained classifier and even achieved better classification accuracy than the daily retraining classifier. Moreover, compared with a conventional RL method, our algorithm improved the accuracy by approximately 10% and the online weight updating speed by approximately 70 times. Conclusions: This paper proposed a self-recalibrating decoder which achieved a good and robust decoding performance with fast weight updating and might facilitate its application in wearable device and clinical practice.