Vadim V. Verbov

Vadim V. Verbov

Auto-generated profile, based on publicly available information

Vadim V. Verbov

Romodanov Neurosurgery Institute, Kyiv, Ukraine

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2021 in Ukrainian Neurosurgical Journal
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVVadim V. Verbov
Vadim V. Verbov
MKMichael Yu. Karpinsky
Michael Yu. Karpinsky
OYOleksandr V. Yaresko
Oleksandr V. Yaresko
Introduction. The thoracolumbar junction is one of the most frequently damaged parts of the human spine when exposed to a traumatic factor. Corpectomy in combination with posterior decompression and restoration of the spinal support function is often performed using an interbody implant and posterior transpedicular stabilization to achieve adequate decompression and stabilization in severe traumatic injuries of this level. The surgery of this type is characterized by significant instability of the operated segment and determines increased requirements for the rigidity and reliability of posterior fixation. We have modeled the situation of a two-level corpectomy with subsequent replacement of bodies with a mesh implant and posterior transpedicular stabilization with 8 screws. Objective. To study the stress-strain state of the thoracolumbar spine model after resection of the Th12-L1 vertebrae with different variants of transpedicular fixation under the influence of a compressive load. Materials and methods. A mathematical finite element model of the human thoracolumbar spine has been developed, the components of which are the Th9 ‒ Th11 and L2-L5 vertebrae (vertebrae Th12-L1 are removed), as well as elements of hardware - interbody support and transpedicular system. Four variants of transpedicular fixation were modeled: using short screws and long screws passing through the cortical layer of anterior wall of vertebral body, as well as two cross links and without them. The stress-strain state of the models was studied under the influence of a vertical compressive distributed load, which was applied to the body of the Th9 vertebra and its articular surfaces. The load value was 350 N, corresponding to the weight of the upper body. Results. d It was found that transpedicular fixation of the thoracolumbar vertebrae with the use of long screws reduces the level of tension in the bone elements of the models. In the area of screw entry into the pedicle of the T10, T11, L2 and L3 vertebral arch, the load when using short screws was 3.1, 1.7, 3.9 and 12.1 MPa, respectively, when using bicortically installed screws - 2.9, 1.8, 3.8 and 10.6 MPa. The addition of two cross-links also reduces the maximum load values in critical areas of the model to a certain extent. In case of short screws combination and two cross-links, the load in these areas was 2.8, 1.7, 3.6 and 11.5 MPa, when using bicortical screws and cross-links - 2.8, 1.6, 3.3 and 9.3 MPa. The study of the stress-strain state of other parts of the model revealed a similar trend. Conclusions. The use of long screws with fixation in the cortical bone of anterior part of the vertebral bodies reduces the level of tension in the bone elements of the models. The use of cross links provides greater rigidity to the transpedicular system, that also reduces the tension in the bone tissue.

30 June 2024 in PAIN, JOINTS, SPINE
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVV.V. Verbov
V.V. Verbov
SVS.A. Verbovska
S.A. Verbovska
ICI.V. Cheshuk
I.V. Cheshuk
Background. Traumatic spinal injuries are a significant medical and social issue, due to both the high costs associated with initial medical care for the injured and the extensive and expensive rehabilitation required. The thoracolumbar junction (TLJ) is prone to injuries due to its biomechanical characteristics. However, the actual frequency of injuries in this area, as reported in the literature, is inconsistent. The purpose of the study was to assess the proportion of fractures at the TLJ within the overall structure of traumatic spinal injuries in the adult population. Materials and me­thods. A meta-analysis was conducted based on searches in the MEDLINE database using MeSH terms and keywords in titles and abstracts to identify studies meeting the inclusion criteria. The search identified 22 full-length articles. Data extraction and analysis were conducted by two independent experts. Results. It was found that fractures at the TLJ accoun­ted for 46.51 % (95% confidence interval (CI): 36.76–56.27 %) of the overall structure of spinal injuries, specifically fractures at level Th11 — 4.26 % (95% CI: 3.35–5.17 %), Th12 — 13.98 % (95% CI: 10.41–17.56 %), at level L1 — 22.21 % (95% CI: 17.66–26.76 %), and L2 — 9.69 % (95% CI: 6.82–12.57 %). Within the thoracolumbar division, the frequency of TLJ trauma was 61.88 % (95% CI: 52.53–71.22 %). Within the TLJ, the frequency of fractures was: vertebra Th11 — 10.2 % (95% CI: 8.05–12.36 %), Th12 — 26.56 % (95% CI: 22.42–30.7 %), vertebra L1 — 42.76 % (95% CI: 39.7–45.81 %), and L2 — 20.48 % (95% CI: 16.73–24.23 %). Conclusions. The meta-analysis provi­ded objective indicators of the frequency distribution of TLJ fractures within the overall structure of traumatic spinal injuries. To our knowledge, this is the first study to provide such detailed information through meta-analysis.

27 June 2021 in Ukrainian Neurosurgical Journal
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVVadim V. Verbov
Vadim V. Verbov
ICIevgen V. Cheshuk
Ievgen V. Cheshuk
MVMilan V. Vorodi
Milan V. Vorodi
Introduction. The thoracolumbar junction is the most common location of traumatic spinal injuries. It accounts for 50-60% of all thoracic and lumbar spine injuries. Spondyloptosis is rather rare, but one of the most severe types of traumatic injury, that is characterized by a severe damage of spinal axis in one or more planes. Traumatic spondyloptosis is classified as reducible and irreducible, depending on the possibility of intraoperative restoration of the spinal axis without resection of the damaged vertebra. Objective. To determine the optimal surgical technique for traumatic irreducible spondyloptosis of thoracolumbar junction. Materials and methods. A retrospective analysis of the patients’ database treated at the Romodanov Neurosurgery Institute, Ukraine was performed over the past 4 years (2017 to 2020) to identify all cases with traumatic irreducible spondyloptosis of the thoracolumbar junction. Results. Treatment outcomes of five patients aged 18 to 52 years (mean age 31.2 years) were analyzed. The minimum period from the moment of injury to surgery was 14 days, the maximum was 3 months and 2 days (on average 42.2 days). At the time of admission all patients had a neurological deficit that corresponds to the functional class A on the American spine injury associatin ASIA scale of severity of spinal cord injury. The TLICS (Thoracolumbar injury classification and severity) score was 8 points. All the patients had the injury of lateral spondyloptosis: in three cases as an isolated displacement only in the coronal plane, in two – as a combined one - in the coronal and sagittal plane. Surgical intervention in all cases was performed from the posterior approach. As a body replacement system in 2 patients, a vertical cylindrical implant (Mesh) was used, in 3 patients - a telescopic body replacing implant. The method of bicortical implantation of pedicle screws was applied. The transpedicular system was strengthened by two cross links of the rod-to-rod type. In all cases the restoration of spinal axis was achieved in both the coronal and sagittal planes. Follow-up examinations were carried out 2, 6 and 12-18 months of the postoperative period. Regression of neurological disorders was registered in two patients, in one case to ASIA B, in the other to ASIA C. Conclusions. Isolated posterior approach has demonstrated high efficacy in the surgical management of traumatic irreducible spondyloptosis of the thoracolumbar junction both in restoring the axis of the spine and in ensuring the stability of fusion.

29 September 2024 in Ukrainian Neurosurgical Journal
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVVadim V. Verbov
Vadim V. Verbov
ICIevgen V. Cheshuk
Ievgen V. Cheshuk
MVMilan V. Vorodi
Milan V. Vorodi
MKMykhailo Y. Karpinsky
Mykhailo Y. Karpinsky
OYOlexander V. Yaresko
Olexander V. Yaresko
Introduction. The treatment of burst fractures at the thoracolumbar junction remains a contentious issue in vertebrology. Despite a broad array of surgical interventions available, many surgeons favor isolated posterior stabilization, which can be performed using either minimally invasive or open approaches. However, the biomechanical properties of these methods have not been thoroughly investigated. Objective: This study aims to evaluate the biomechanical stability of the thoracolumbar junction following transpedicular stabilization of a burst fracture at the Th12 vertebra, under different system configurations influenced by lateral flexion. Materials and Methods: A mathematical finite element model of the human thoracolumbar spine, featuring a burst fracture at the Th12 vertebra, was developed. The model included a transpedicular stabilization system with eight screws, simulating “long” stabilization. We examined four variants of transpedicular fixation using both mono- and bicortical screws, with and without the inclusion of two cross-links. Results: The study found that the load borne by the damaged Th12 vertebral body varied depending on the fixation system employed. Specifically, stress levels were 24.0 MPa, 27.3 MPa, 18.4 MPa, and 25.8 MPa for models with short screws without cross-links, long screws without cross-links, short screws with cross-links, and long screws with cross-links, respectively. At the screw entry points in the vertebral arch, the highest stress values were recorded at the L2 vertebra, showing 11.8 MPa, 14.0 MPa, 9.4 MPa, and 13.4 MPa for each respective model. Among the metal construct elements, the connecting rods consistently exhibited the highest stress, with values of 226.7 MPa, 313.4 MPa, 212.4 MPa, and 293.98 MPa, respectively. Conclusion: The results underscore that utilizing cross-links in the stabilization of burst fractures at the thoracolumbar junction, which is only feasible through an open installation, somewhat mitigates stress within the stabilized spinal segment. Meanwhile, the modeling of lateral flexion revealed only minimal differences in stress values between open and minimally invasive installations.

30 September 2025 in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVVadim Verbov
Vadim Verbov
ICIevgen Cheshuk
Ievgen Cheshuk
MKMykhailo Karpinsky
Mykhailo Karpinsky
OYOlexander Yaresko
Olexander Yaresko
Thoracolumbar junction fractures account for up to 60 % of all spinal injuries, with more than 20 % classified as burst fractures. These injuries are characterized by instability and an increased risk of kyphotic deformity. Short-segment transpedicular fixation, which has been gradually gaining favor as the treatment of choice for burst fractures in this region, undoubtedly reduces invasiveness but can lead to fixation failure if there is no intermediate support in the body of the injured vertebra. Objective. To evaluate the stress-strain state of the thoracolumbar spine with a burst fracture at ThXII under extension loading, considering screw length and the presence of intermediate fixation. Methods. A finite element model of the spine (ThIX–LV) with a burst fracture at ThXII was developed. Four variants of shortsegment transpedicular fixation were analyzed: short or long (bicortical) screws, with or without additional screws in ThXII. A 350 N load was applied to ThIX, and stresses were determined at control points using the von Mises criterion. Results. The highest stresses in the connecting rods were observed with long screws without intermediate fixation (337.2 MPa). Introducing intermediate screws decreased the stress in ThXII from 16.2 to 9.8 MPa. Short screws with ThXII fixation distributed loads more effectively, reducing peak stresses. Long screws led to overload at the entry points (up to 12.8 MPa in LI), while their maximum stress reached 95.1 MPa. Conclusions. Intermediate fixation of the injured vertebra reduces stress in both bone structures and the implant, thereby decreasing the risk of correction loss. The most favorable configuration is a combination of short screws with intermediate fixation. Long screws are advisable in cases of osteoporosis, although they increase local stresses — a factor that must be taken into consideration during surgical planning.

26 April 2024 in MOJ Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
ONOleksii Nekhlopochyn
Oleksii Nekhlopochyn
VVVadim V Verbov
Vadim V Verbov
ICIevgen V Cheshuk
Ievgen V Cheshuk
MKMichael Yu Karpinsky
Michael Yu Karpinsky
OYOleksandr V Yaresko
Oleksandr V Yaresko
Traumatic spinal injuries pose a significant medico-social challenge, with about 60% of all spine fractures occurring at the thoracolumbar junction. Optimizing care for these patients remains a critical issue, despite the development of numerous surgical and conservative treatment methods, with outcomes still far from ideal. A key factor contributing to the consistently high rate of unsuccessful surgical interventions, which lead to stabilization failures in both the early and late postoperative periods, is the disregard of the biomechanical characteristics of the thoracolumbar junction area. Clinical protocols often regulate intervention methods based on the degree and nature of damage to the thoracolumbar spine as a whole. Enhancing the reliability of fixation, while maintaining the number of transpedicular screws, can be significantly achieved by using cross-links and adjusting screw length. The purpose of our study was to investigate the distribution of loads on the metal construct elements and bone structures in the thoracolumbar junction after extensive decompressive-stabilizing interventions. The load was modeled with a backward tilt. A mathematical finite element model of the human thoracolumbar spine segment was developed, incorporating vertebrae Th9-Th11, L2-L5, with Th12-L1 vertebrae removed, as well as elements of the metal construct—interbody support and a transpedicular system. We modeled four variants of transpedicular fixation using both short and long screws that penetrate the anterior surface of the vertebral body, with and without the use of two cross-links. Stress parameters were monitored at 20 control points in the models. Comparative analysis of the results revealed that models including long bicortical screws and two cross-links demonstrated the best biomechanical performance when the torso was tilted backward, effectively reducing stress in critical areas and enhancing the durability and effectiveness of the fixation.